MAURY USCG vessel records Sign in
← All vessels

PAKELOT

PAKELOT is a 1980 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 1987, most recently in July 1996, along with 17 deficiencies.

Records from 1987 to 1996. Most recent: inspection, 20 July 1996.

Built
1980
Last inspected
20 July 1996
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTV7556
183992
Flag
UNITED STATES
—
Maury page id
psix-183992

Inspections, by type

…with no type recorded4
Years with a record 6 calendar years (1987–1996)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.9 ft × 16.1 ft × 7.6 ft
Registered tonnagegross 87 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC M C MARINE · FERNDALE WA · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPETERSBURG, AK
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
73 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WTV7556MMSI not assigned · expired · compulsorily equipped · granted 28 June 1996, cancelled 30 September 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 14

20 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1086993
21 August 1991 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1252215
21 August 1991 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1252405
6 June 1991 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 931658
13 May 1991 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1240032
8 March 1991 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1222081
5 November 1990 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 905500
1 May 1990 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 918621
1 May 1990 Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1221006
10 June 1989 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 887065
10 June 1989 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1044531
24 April 1989 COI Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1350761
28 December 1988 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1349194
4 September 1987 COI Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1003358

Deficiency record · 17

Engineering
Issued 8 March 1991 Resolved
OIL AND WATER IN BILGES IN THE ENGINE ROOM.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Fire Fighting
Issued 8 March 1991 Resolved
FIRE EXTINGUISHER INSTALLED ON DECK CRANE DOES NOT HAVE A SUITABLE EXTINGUISHER BRACKET
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Deck/Cargo
Issued 8 March 1991 Resolved
THE VESSELDID NOT HAVE A PROPER STABILITY TEST DONE (INCLINE). VESSEL IS NOT ALLOEWD TO OPERATE DECK CRANE UNLESS IS AT SHORE OR TIED UP AT A PIER (NOT IN OPEN WATER).
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Engineering
Issued 8 March 1991 Resolved
FLAME SCREENS INSTALLED ON THE FUEL TANK VENTS IS NOT 30X30.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Electrical
Issued 8 March 1991 Resolved
ON THE FWD BHD OF THE ER OTBD OF STBD ENG A TERMINAL CONNECTION IS MISSING A COVER.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Accommodation/Occupational Safety
Issued 8 March 1991 Resolved
GALLEY STOVE OIL TANK IS LOCATED ON DECK BEHIND THE BRIDGE AND DOES NOT HAVE A 30X30 FLAME SCREEN INSTALLED.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Construction/Loadline
Issued 8 March 1991 Resolved
IN THE PORT AND STBD FWD VOIDS IN THE AREA WHERE THE VOID TOPS MEET THE FWDBHD OF THE VOID THERE ARE THREADED FASTNERS THRU THE FWD BHD. THESE THREADED FASTNERS WERE AT ONE TIME USED TO HOLD THE GASKET FOR THE BOW RAMP. THE FASTNERS ARE TO BE REMOVED AND THE HOLES DRILLED OUT AND WELDED
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Construction/Loadline
Issued 8 March 1991 Resolved
IN THE PORT FWD VOID IN THE AREA OF THE WEB FRAME AND 1ST LONG. THERE IS ANWELD 3"LONG THAT HAS WELDING ROD STUBS IN IT GRIND OUT AND REWELD.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Construction/Loadline
Issued 8 March 1991 Resolved
IN THE STBD FWD VOID IN THE AREA OF AND TO THE PORT OF THE 1ST LONG. THERE IS A LONGITUDINAL WELD THAT HAS SEVERE POROSITY FOR A LENGTH OF 5 FEET. GRIND OUT AND REWELD USING PROPER WELDING PROCEDURES.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Accommodation/Occupational Safety
Issued 8 March 1991 Resolved
EXISTING RAILING ON DECK AFT OF GALLEY IS NOT 36" IN HEIGHTH. RAILING NEEDSTO BE ADDED OR HAND GRABS INSTALLED.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Lifesaving
Issued 1 May 1990 Resolved
3 RED, 3 ORANGE FLARES OUTDATED.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Electrical
Issued 1 May 1990 Resolved
LINERS FOR BATTERY BOXES MISSING.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Documentation
Issued 1 May 1990 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Lifesaving
Issued 1 May 1990 Resolved
EPIRB NOT OPERABLE
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Lifesaving
Issued 1 May 1990 Resolved
VESSEL HAS NO RAFTAGE OF ANY TYPE.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Engineering
Issued 1 May 1990 Resolved
NO FLAME SCREENS ON FUEL FILTERS
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Construction/Loadline
Issued 24 April 1989 Resolved
CROP OUT AND RENEW BOTTOM PLAT AT THE BOW PORT SIDE FROM THE WATER LINE DOWN 2 FEET AND OUT FROM THE KEEL TO THE FIRST PORT LONGITUDNAL.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.