Records from 1987 to 1996. Most recent: inspection, 20 July 1996.
Documentation record
Registered dimensions (L × B × D)60.9 ft × 16.1 ft × 7.6 ft
Registered tonnagegross 87 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC M C MARINE · FERNDALE WA · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPETERSBURG, AK
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
73 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
20 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1086993
21 August 1991
Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1252215
21 August 1991
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1252405
6 June 1991
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 931658
13 May 1991
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1240032
8 March 1991
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1222081
5 November 1990
Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 905500
1 May 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 918621
1 May 1990
Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1221006
10 June 1989
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 887065
10 June 1989
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1044531
24 April 1989
COI Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1350761
28 December 1988
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1349194
4 September 1987
COI Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1003358
Engineering
Issued 8 March 1991
Resolved
OIL AND WATER IN BILGES IN THE ENGINE ROOM.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Fire Fighting
Issued 8 March 1991
Resolved
FIRE EXTINGUISHER INSTALLED ON DECK CRANE DOES NOT HAVE A SUITABLE EXTINGUISHER BRACKET
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Deck/Cargo
Issued 8 March 1991
Resolved
THE VESSELDID NOT HAVE A PROPER STABILITY TEST DONE (INCLINE). VESSEL IS NOT ALLOEWD TO OPERATE DECK CRANE UNLESS IS AT SHORE OR TIED UP AT A PIER (NOT IN OPEN WATER).
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Engineering
Issued 8 March 1991
Resolved
FLAME SCREENS INSTALLED ON THE FUEL TANK VENTS IS NOT 30X30.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Electrical
Issued 8 March 1991
Resolved
ON THE FWD BHD OF THE ER OTBD OF STBD ENG A TERMINAL CONNECTION IS MISSING A COVER.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Accommodation/Occupational Safety
Issued 8 March 1991
Resolved
GALLEY STOVE OIL TANK IS LOCATED ON DECK BEHIND THE BRIDGE AND DOES NOT HAVE A 30X30 FLAME SCREEN INSTALLED.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Construction/Loadline
Issued 8 March 1991
Resolved
IN THE PORT AND STBD FWD VOIDS IN THE AREA WHERE THE VOID TOPS MEET THE FWDBHD OF THE VOID THERE ARE THREADED FASTNERS THRU THE FWD BHD. THESE THREADED FASTNERS WERE AT ONE TIME USED TO HOLD THE GASKET FOR THE BOW RAMP. THE FASTNERS ARE TO BE REMOVED AND THE HOLES DRILLED OUT AND WELDED
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Construction/Loadline
Issued 8 March 1991
Resolved
IN THE PORT FWD VOID IN THE AREA OF THE WEB FRAME AND 1ST LONG. THERE IS ANWELD 3"LONG THAT HAS WELDING ROD STUBS IN IT GRIND OUT AND REWELD.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Construction/Loadline
Issued 8 March 1991
Resolved
IN THE STBD FWD VOID IN THE AREA OF AND TO THE PORT OF THE 1ST LONG. THERE IS A LONGITUDINAL WELD THAT HAS SEVERE POROSITY FOR A LENGTH OF 5 FEET. GRIND OUT AND REWELD USING PROPER WELDING PROCEDURES.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Accommodation/Occupational Safety
Issued 8 March 1991
Resolved
EXISTING RAILING ON DECK AFT OF GALLEY IS NOT 36" IN HEIGHTH. RAILING NEEDSTO BE ADDED OR HAND GRABS INSTALLED.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Lifesaving
Issued 1 May 1990
Resolved
3 RED, 3 ORANGE FLARES OUTDATED.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Electrical
Issued 1 May 1990
Resolved
LINERS FOR BATTERY BOXES MISSING.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Documentation
Issued 1 May 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Lifesaving
Issued 1 May 1990
Resolved
EPIRB NOT OPERABLE
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Lifesaving
Issued 1 May 1990
Resolved
VESSEL HAS NO RAFTAGE OF ANY TYPE.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Engineering
Issued 1 May 1990
Resolved
NO FLAME SCREENS ON FUEL FILTERS
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Construction/Loadline
Issued 24 April 1989
Resolved
CROP OUT AND RENEW BOTTOM PLAT AT THE BOW PORT SIDE FROM THE WATER LINE DOWN 2 FEET AND OUT FROM THE KEEL TO THE FIRST PORT LONGITUDNAL.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989