← All vessels
HOEGH AURORA
HOEGH AURORA is a 2024 freight ship. The Coast Guard has recorded 4 inspections in 2025, along with 2 deficiencies — 1 with no resolution recorded — and 1 operational control.
Records in 2025. Most recent: inspection, 12 March 2025.
- Built
- 2024
- Last inspected
- 12 March 2025
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 2 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Inspection record
Last inspected
12 March 2025
…with no type recorded1
Deficiencies
2 recorded · 1
without a recorded resolution
Operational controls
None recorded without a removal date
Years with a record
1 calendar year (2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Identity
Documentation record
Tonnage as PSIX records it25563 - Dead Weight, Metric Ton
84074 - Convention (Subpart B), Gross Ton
84074 - Regulatory (Subpart C or D), Gross Ton
84074 - Convention (Subpart B), Gross Ton
84074 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 4
12 March 2025
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8091037
7 March 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8090251
4 March 2025
PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8085128
1 March 2025
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8086734
Deficiency record · 2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 March 2025
No resolution recorded
The inspection and maintenance of electrical installations in explosion hazardous spaces shall be performed in accordance with a recognized standard. PSCO found numerous electrical connectors/glands loose in hazardous spaces/areas.
SOLAS II-I/57
IGF Code Part A/6.4.1.8
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 March 2025
Resolved
An inspection/survey plan for the liquified gas fuel containment system shall be developed and approved by the Administration. PSCO observed no approved site survey plan.
SOLAS II-1/57
IGF Code Part C-1/18.3.3
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.