← All vessels
SFL ARUBA
SFL ARUBA is a 2022 tank ship. The Coast Guard has recorded 2 inspections in 2025, along with 3 deficiencies.
Records in 2025. Most recent: inspection, 17 November 2025.
- Built
- 2022
- Last inspected
- 17 November 2025
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9919761
V7A6841
1843506
Flag
MARSHALL ISLANDS
Maury page id
psix-1843506
Inspections, by type
Years with a record
1 calendar year (2025)
The 2 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it22467 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 2
17 November 2025
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8269930
14 October 2025
PSC A · COC-CHEM & TVE Renew
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8249590
Deficiency record · 3
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 October 2025
Resolved
The inspection and maintenance of electrical installations in explosion hazardous spaces shall be performed in accordance with a recognized standard. Ship cannot provide documentary proof of individuals conducting maintenance, repairs, insulation, etc. in hazardous areas.
SOLAS(20) II-I/57 IGF Code 18.3.3
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 October 2025
Resolved
An inspection/ survey plan for the liquified gas fuel containment system shall be developed and approved by the admin. Ship cannot provide documentary proof of flag inspection survey for fuel gas system.
74SOLAS(20) II-I/57 IGF Code 6.4.1.8
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 October 2025
Resolved
Monitoring of gas supply system to main engine for the double walled piping does not meet the prescriptive requirement of Table 1 in IGF Code. Ships crew shall verify discrepancy between LEL for pre-alarm and high level alarm as demonstrated (20%/ 30% vs. 30%/ 60%).
74SOLAS(20) II-I/57 IGF Code 15.11 Table 1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.