MAURY USCG vessel records Sign in
← All vessels

ASIAN CAPTAIN

ASIAN CAPTAIN is a 1998 freight ship. The Coast Guard has recorded 25 inspections since 2003, most recently in March 2026, along with 17 deficiencies and 6 operational controls.

Records from 2003 to 2026. Most recent: inspection, 2 March 2026.

Built
1998
Last inspected
2 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9158616 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
SOUTH KOREA
—
Maury page id
psix-18438

Inspections, by type

…with no type recorded4
Years with a record 13 calendar years (2003–2026)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it71383 - Regulatory (Subpart C or D), Gross Ton
25082 - Dead Weight, Metric Ton
26779 - Regulatory (Subpart C or D), Net Ton
46847 - Displacement, Metric Ton
71383 - Convention (Subpart B), Gross Ton
26779 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

2 March 2026 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8310414
3 November 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8262253
26 October 2025 In-Service Inspection · MARPOL Annex I Examination · Appeal · ISM Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8258918
13 August 2025 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8209424
10 August 2025 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8206400
20 November 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8037682
29 December 2023 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7841768
29 October 2022 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7585837
21 October 2022 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7578608
9 January 2020 ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6880075
11 January 2019 Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6604587
24 December 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6326731
10 November 2016 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6039273
19 October 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6023967
30 September 2016 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6013046
17 February 2016 Ballast Water Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5815375
16 February 2016 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5815406
21 July 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5191630
20 July 2015 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5186925
16 July 2015 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5185905
21 August 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4961060
18 August 2014 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4951187
4 March 2004 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2018061
6 December 2003 Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1956968
5 December 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1961545

Deficiency record · 17

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 26 October 2025 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that appropriate corrective action is taken. The technical nature of the deficiencies noted below provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency. 74 SOLAS (2024) IX/3.1 ISM Code 10.2.3 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 November 2025
Resolution: Submitted copy of external audit (attached in documents)
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 October 2025 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed multiple instances of leaking fuel oil piping, soaking the lagging servicing the piping around the #1 auxiliary engine, purifiers, main engine, diesel oil service tank, heavy fuel oil settling tank, and lube oil lagging below main engine, creating a flammable environment. 74 SOLAS (1997) II-2/15.2 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 November 2025
Resolution: Received class report and photos attesting to rectification of leaks, removal of affected lagging, and cleaning of affected areas.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2025 Resolved
All electrical apparatus shall be so constructed and so installed as to not to cause injury when handled or touched in a normal manner. PSCO observed electrical wire on #2 emergency steering leading to directional control valve hanging outside of its original conduit, and soaked in oil. 74 SOLAS (2004) II-1/45.1.3 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 November 2025
Resolution: Received class report attesting to cleaning of oil and rectification of electrical wiring issue.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 October 2025 Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 44.1 and 44.2. PSCO observed A0 fire door leading to steering room compromised due to drill holes in door and failing latch plate. 74 SOLAS (1997) II-2/44.1 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2025
Resolution: Received class report and photos attesting to repair of door.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2025 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. PSCO observed a junction box on the overhead without a cover exposing the wiring. 74 SOLAS (2004) II-1/45.1.3 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2025
Resolution: Received class report and photos demonstrating replacement of missing junction box cover.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 26 October 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO received notification that the stern tube seal failed allowing lube oil to discharge and create sheen on waterway. 74 SOLAS (2020) I/11(a) 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2025
Resolution: Received class report, photos, and service technician's report attesting to repair of leaking packing gland.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 October 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed significant leak, constant stream, of water coming from fresh water generator. 74 SOLAS (2020) I/11(a) 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2025
Resolution: Received class report and photos attesting to repair of water leak.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2025 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. PSCO observed electrical wiring leading to pick up sensor on exhaust turbo appearing to be secured with electrical tape and mousing wire. 74 SOLAS (2004) II-1/45.1.3 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2025
Resolution: Received photos of rectification and class report attesting to repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 October 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed #1 steering unit directional control valve has been modified with self manufactured buttons to operate steering to port and starboard. 74 SOLAS (2020) I/11(a) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2025
Resolution: Received class documentation attesting to the functionality of the steering unit directional control valve.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2025 Resolved
Exposed metal parts of electrical machines or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed. PSCO observed grounding cables on steering pumps #1 and #2 disconnected. 74 SOLAS (2004) II-1/45.1.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 October 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 October 2022 Resolved
(13102) In addition to the requirements contained elsewhere in the present regulation, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. PSCO observed multiple leaks on the #1 and #2 generators originating from the head gaskets. 74SOLAS(04) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2022
Resolved 29 October 2022
Resolution: Class survey received attesting to repairs. Head gaskets on #1 and #2 generators renewed/cleaned. Crew members inspected all generators and found in order.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2022 Resolved
(13199) The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed soft patch on pilot fule line for boiler. 74 SOLAS(04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 October 2022
Resolution: Vessel replaced the pilot fuel line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 October 2022 Resolved
(11117) Self-activating smoke signals required by regulation 11-1/7.1.3 shall: be provided with quick release arrangement that will automatically release and activate the signal and associated self-igniting light connected to a lifebuoy. PSCO observed self igniting light was tied off to the bracket and could not quick release. 74SOLAS(20) III/34 LSA 2.1.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 21 October 2022
Resolution: Vessel untied the Self-igniting light.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 19 October 2016 Resolved
1320 Ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society which is recognized by the administration. PSCO observed port side anchor chain with loose stud. SOLAS 2004 CH.II-1 Reg.3-1 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 November 2016
Resolution: Received [name withheld] attesting to repairs
Engineering › Generator (propulsion-electric) › Battery
Issued 21 August 2014 Resolved
1400 - Each emergency generating set arranged to be automatically started shall be equipped with starting devices with a stored energy capability of at least 3 consecutive starts. The emergency generator could not be started by battery starting devices due to a low charge on the battery bank caused by a loose connection. 74 SOLAS (04) II-1/44.2
Action required: 705 - Other - as specified
Resolved 21 August 2014
Resolution: Battery was replaced and connection was tightened. Emergency generator started up when test was initiated.
Engineering › Fuel Oil Service System › Valve
Issued 18 August 2014 Resolved
Upon examining the emergency fuel shut-off valve for the service tank to the main engine and the settling tank to the fuel oil purifier there were 2 bolts observed blocking each of the spring loaded valve actuators. The bolts prohibited the valve from closing, which in the event of operation, would allow heavy fuel oil to flow freely into the space. Vessel Detained, see FORM B
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2014
Resolution: See activity #4951187 Documentation for scanned in KRS class report.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 18 August 2014 Resolved
As per Safety Management Plan, weekly visual checks of the quick closing valves are required. PSCO discovered signatures for every week since 30 JUN 14 (which were the operational test of the quick closing valves annotated in deficiency 01) attesting to visual inspection of all quick closing valves. Ships crew attested to the bolts being placed in service following operation test on 30 JUN 14.
Action required: 705 - Other - as specified
Due 17 September 2014
Resolved 21 August 2014
Resolution: Received class report attesting to a single point of failure of the 2nd engineer. Nothing was found indicating a failure of the SMS.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.