MAURY USCG vessel records
← All vessels

ASIAN CAPTAIN

ASIAN CAPTAIN is a 1998 freight ship. The Coast Guard has recorded 17 inspections since 2016, most recently in March 2026, along with 14 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 2 March 2026.

Built
1998
Last inspected
2 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9158616
Flag
SOUTH KOREA
Maury page id
psix-18438

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it71383 - Regulatory (Subpart C or D), Gross Ton
25082 - Dead Weight, Metric Ton
26779 - Regulatory (Subpart C or D), Net Ton
46847 - Displacement, Metric Ton
71383 - Convention (Subpart B), Gross Ton
26779 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 17

2 March 2026 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8310414
3 November 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8262253
26 October 2025 In-Service Inspection · MARPOL Annex I Examination · Appeal · ISM Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8258918
13 August 2025 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8209424
10 August 2025 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8206400
20 November 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8037682
29 December 2023 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7841768
29 October 2022 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7585837
21 October 2022 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7578608
9 January 2020 ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6880075
11 January 2019 Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6604587
24 December 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6326731
10 November 2016 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6039273
19 October 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6023967
30 September 2016 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6013046
17 February 2016 Ballast Water Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5815375
16 February 2016 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5815406

Deficiency record · 14

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 26 October 2025 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that appropriate corrective action is taken. The technical nature of the deficiencies noted below provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency. 74 SOLAS (2024) IX/3.1 ISM Code 10.2.3 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 November 2025
Resolution: Submitted copy of external audit (attached in documents)
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 October 2025 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed multiple instances of leaking fuel oil piping, soaking the lagging servicing the piping around the #1 auxiliary engine, purifiers, main engine, diesel oil service tank, heavy fuel oil settling tank, and lube oil lagging below main engine, creating a flammable environment. 74 SOLAS (1997) II-2/15.2 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 November 2025
Resolution: Received class report and photos attesting to rectification of leaks, removal of affected lagging, and cleaning of affected areas.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2025 Resolved
All electrical apparatus shall be so constructed and so installed as to not to cause injury when handled or touched in a normal manner. PSCO observed electrical wire on #2 emergency steering leading to directional control valve hanging outside of its original conduit, and soaked in oil. 74 SOLAS (2004) II-1/45.1.3 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 November 2025
Resolution: Received class report attesting to cleaning of oil and rectification of electrical wiring issue.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 October 2025 Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 44.1 and 44.2. PSCO observed A0 fire door leading to steering room compromised due to drill holes in door and failing latch plate. 74 SOLAS (1997) II-2/44.1 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2025
Resolution: Received class report and photos attesting to repair of door.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2025 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. PSCO observed a junction box on the overhead without a cover exposing the wiring. 74 SOLAS (2004) II-1/45.1.3 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2025
Resolution: Received class report and photos demonstrating replacement of missing junction box cover.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 26 October 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO received notification that the stern tube seal failed allowing lube oil to discharge and create sheen on waterway. 74 SOLAS (2020) I/11(a) 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2025
Resolution: Received class report, photos, and service technician's report attesting to repair of leaking packing gland.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 October 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed significant leak, constant stream, of water coming from fresh water generator. 74 SOLAS (2020) I/11(a) 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2025
Resolution: Received class report and photos attesting to repair of water leak.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2025 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. PSCO observed electrical wiring leading to pick up sensor on exhaust turbo appearing to be secured with electrical tape and mousing wire. 74 SOLAS (2004) II-1/45.1.3 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2025
Resolution: Received photos of rectification and class report attesting to repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 October 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed #1 steering unit directional control valve has been modified with self manufactured buttons to operate steering to port and starboard. 74 SOLAS (2020) I/11(a) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2025
Resolution: Received class documentation attesting to the functionality of the steering unit directional control valve.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2025 Resolved
Exposed metal parts of electrical machines or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed. PSCO observed grounding cables on steering pumps #1 and #2 disconnected. 74 SOLAS (2004) II-1/45.1.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 October 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 October 2022 Resolved
(13102) In addition to the requirements contained elsewhere in the present regulation, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. PSCO observed multiple leaks on the #1 and #2 generators originating from the head gaskets. 74SOLAS(04) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2022
Resolved 29 October 2022
Resolution: Class survey received attesting to repairs. Head gaskets on #1 and #2 generators renewed/cleaned. Crew members inspected all generators and found in order.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2022 Resolved
(13199) The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed soft patch on pilot fule line for boiler. 74 SOLAS(04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 October 2022
Resolution: Vessel replaced the pilot fuel line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 October 2022 Resolved
(11117) Self-activating smoke signals required by regulation 11-1/7.1.3 shall: be provided with quick release arrangement that will automatically release and activate the signal and associated self-igniting light connected to a lifebuoy. PSCO observed self igniting light was tied off to the bracket and could not quick release. 74SOLAS(20) III/34 LSA 2.1.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 21 October 2022
Resolution: Vessel untied the Self-igniting light.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 19 October 2016 Resolved
1320 Ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society which is recognized by the administration. PSCO observed port side anchor chain with loose stud. SOLAS 2004 CH.II-1 Reg.3-1 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 November 2016
Resolution: Received [name withheld] attesting to repairs

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.