MAURY USCG vessel records
← All vessels

WHITE SKY

WHITE SKY is a tank ship. The Coast Guard has recorded 2 inspections in 2024, along with 4 deficiencies — 3 with no resolution recorded —.

Records in 2024. Most recent: inspection, 6 October 2024.

Built
Not recorded
Last inspected
6 October 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9528718
CQ2217
1849488
Flag
PORTUGAL
Maury page id
psix-1849488

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 1 calendar year (2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it4387 - Convention (Subpart B), Gross Ton
5927 - Dead Weight, Ton
1745 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

6 October 2024 VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8028877
5 October 2024 PSC A · COC-TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8014673

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 October 2024 No resolution recorded
A fixed fire detection system shall comply with the Fire Safety System Code. Detectors shall be located for optimum performance. Positions near ventilation ducts where patterns of airflow could adversely affect performance shall be avoided. Air ventilation duct is impeding the functionality of the fixed heat and smoke detectors positioned above the #2 generator. 74SOLAS(09) II-2/7.2.2 FSS Code 9.2.4.1
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 8 October 2024 No resolution recorded
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. PSCO observed air flow coming through the cargo control room hatch, an A-15 Class Boundary Door that shall prevent the passage of fire and smoke. 74SOLAS(09) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 October 2024 No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Protective chain link railing and welded eyes were rusted off surrounding the transfer manifold area on both port and starboard side of the pumproom. 74SOLAS(20) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 October 2024 Resolved
The main steering gear and rudder stock shall be capable of putting the rudder from 35 degrees on one side to 30 degrees on the other side in not more than 28s. #1 main steering pump was inoperable during local steering test. 74SOLAS(04) II-1/29.3.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 October 2024
Resolved 8 October 2024
Resolution: Vessel performed corrective measures and purged air out of the steering gear hydraulic pump. This allowed for proper functioning of the #1 steering gear.

Ownership record