Records from 2024 to 2026. Most recent: inspection, 15 June 2026.
Inspection history · 5
15 June 2026
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8404982
11 August 2025
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8207107
19 December 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8049381
16 December 2024
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8048105
30 November 2024
PSC A
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8038465
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for personnel on ships subject to the IGF Code
Issued 15 June 2026
No resolution recorded
The inspection and maintenance of electrical installations in explosion hazardous spaces shall be performed in accordance with a recognized standard. PSCO could not verify that the required crewmember/s hold the documentary proof to conduct inspections and maintenance of explosion hazardous spaces/areas.
74 SOLAS (24)
II-1 Reg 57
IGF Code 18.3.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 11 August 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO received an email about and observed inoperable davit winch for rescue boat.
74SOLAS(20)III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2025
Resolved 13 August 2025
Resolution: Received Technician/Class report stating,the winch brake and shaft were completely dismantled and then reassembled with the bearing installed. Upon completion, a dynamic brake test was conducted and confirmed to be in good working order.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 30 November 2024
Resolved
The angular position of the rudder shall be recognizable in the steering gear compartment. PSCO observed the rudder angle indicator in the steering gear compartment was not calibrated to the actual position if the rudder post when operated by the auxiliary steering gear control system.
CITE: 74SOLAS(20) II-1/11.2 Action Taken: 16AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2024
Resolved 16 December 2024
Resolution: Recieved class Report.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 30 November 2024
Resolved
Ships using low flashpoint fuels shall comply with the requirements of the IGF code. Gas related ship specific drills or exercises have not been conducted on board and are not specified in the ships safety management system.
Cite 74SOLAS(20)II-1/57 Action Taken 16AC
IGF Code 17
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2024
Resolved 16 December 2024
Resolution: Received Class report.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 30 November 2024
Resolved
Ships using low flashpoint fuels shall comply with the requirements of the IGF code. In-service maintenance and testing of the gas detection system cannot be demonstrated by the crew. It is unclear if the frequency and resources used for testing are specified in the ships safety management system.
Cite 74SOLAS(20)II-1/57 Action Taken 16AC
IGF Code 18.3.2/6.4.1.8
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2024
Resolved 19 December 2024
Resolution: Received satisfactory class report.