MAURY USCG vessel records
← All vessels

NAUTILUS LAKE MICHIGAN

NAUTILUS LAKE MICHIGAN is a 2025 passenger vessel (inspected). The Coast Guard has recorded 2 inspections since 2024, most recently in September 2025, along with 12 deficiencies.

Records from 2024 to 2025. Most recent: inspection, 3 September 2025.

Built
2025
Last inspected
3 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 September 2025
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2024–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ5713
1849931
Flag
UNITED STATES
Maury page id
psix-1849931

Documentation record

Registered dimensions (L × B × D)43.0 ft × 16.0 ft × 3.8 ft
Registered tonnagegross 8 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA&M MANUFACTURING INC · ALACHUA, FL, UNITED STATES · built 2025
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Net Ton
8 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

3 September 2025 Initial Certification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8218666
4 December 2024 Construction Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8160901

Deficiency record · 12

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 September 2025 Resolved
On a vessel on which the number of passengers permitted on the upper decks is limited by stability criteria, the maximum number of passengers allowed on the upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. The maximum number of passengers permitted on the upper deck (31) is not marked. Mark the same.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Received photographic evidence of completion.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 3 September 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 September 2025
Resolution: Received confirmation of pre-employment test and addition to random drug testing pool.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 3 September 2025 Resolved
Each Employee Assistance Program (EAP) must include an education program including display and distribution of a community service hot-line number. The EAP hot-line number is not displayed. Post the same.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Received photographic evidence of completion.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 3 September 2025 Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Received photographic evidence of completion.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 September 2025 Resolved
Each floating waterlight must be approved in accordance with 46 CFR 161.010. In order to maintain approval the battery recommended by the manufacture and printed on the label must be used. The installed battery is not the recommended battery. Replace with the proper battery.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Received photographic evidence of completion.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 September 2025 Resolved
Each floating waterlight on a vessel carrying only one ring buoy, must be attached to the ring buoy with a corrosion resistant clip. The floating waterlight lanyard is tied to the ring buoy. Provide a corrosion resistant clip and attach lanyard around the body of the ring buoy.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Received photographic evidence of completion.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 3 September 2025 Resolved
Each vessel must be equipped with a public address system. A vessel with more than one passenger deck must have the public address system operable from the operating station. On a vessel of less than 65ft, a battery powered bullhorn may serve as the public address system if audible throughout the accommodation spaces during normal operating conditions. The vessel is not provided with a PA system or battery powered bullhorn. Provide the same.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Received photographic evidence of completion.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 3 September 2025 Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. The watertight hatch covers port and starboard, aft, are not provide with devices to prevent loss. Provide the same.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Received photographic evidence of completion.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 September 2025 Resolved
Commercial hybrid personal flotation devices must be approved in accordance with 46 CFR 160.077. The hybrid flotation devices on board the vessel are not approved under 46 CFR 160.077. Provide hybrid flotation devices meeting 160.077 or work vests approved under 160.053.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Received photographic evidence of completion.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 September 2025 Resolved
A seat must be constructed to minimize the possibility of injury. Several seat are missing hardware at the deck connection. Replace all missing hardware.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Received photographic evidence of completion.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 3 September 2025 Resolved
The Master and crew of the vessel shall be familiar with and have posted at the operating station emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. The emergency instructions are not posted. Post the same.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Received photographic evidence of completion.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 September 2025 Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life jacket and ring buoy. Ensure each ring buoy and life jacket are marked with the full name of the vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Received photographic evidence of completion.

Ownership record