Records from 2025 to 2026. Most recent: inspection, 19 May 2026.
Documentation record
Registered dimensions (L × B × D)52.3 ft × 16.0 ft × 3.8 ft
Registered tonnagegross 10 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA&M MANUFACTURING INC · ALACHUA, FL, UNITED STATES · built 2025
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 April 2026
Resolved
A vessel on a Great Lakes route must carry six orange distress signals. The vessel is only provided with 4 orange distress signals. Provide 2 additional distress signals.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 April 2026
Resolved
A portable hand bilge pump must be provided with a suction hose capable of reaching the bilge of each watertight compartment. Provide a suction hose that is capable of reaching the bilge of each watertight compartment.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2026
Resolved 19 May 2026
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 April 2026
Resolved
A vessel must carry adequate and up-to-date charts of a large enough scale to make safe navigation possible. Provide a chart of the area of operation on the Chicago River.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2026
Resolved 19 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2025
Resolved
Fire buckets must have the words "FIRE BUCKET" stenciled in a contrasting color on each bucket. The provided fire buckets do not contain the required stencil. Mark the three fire buckets with the words "FIRE BUCKET".
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 7 August 2025
Resolution: Witnessed proper markings on all fire buckets.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 June 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents. Provide a first-aid kit that meets 46 CFR 199.175(b)(10) (ISO 18813:2006(E)).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 7 August 2025
Resolution: Witnessed first-aid kit with all required contents.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 25 June 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 7 August 2025
Resolution: Witnessed EAP policy. Owner sated all training has been completed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 25 June 2025
Resolved
The EAP education program must include the display of a community service hotline telephone number for crewmembers assistance. There is no hotline number displayed. Display the same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2025
Resolved 7 August 2025
Resolution: EAP telephone number has been posted inside battery area.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 June 2025
Resolved
Portable watertight containers for distress flares and smoke signals shall be marked in legible contrasting letters at least .5 inches high "DISTRESS SIGNALS". The watertight container for the distress signals is not marked. Mark the same.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 7 August 2025
Resolution: Witnessed proper marking on watertight container containing distress signals.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 June 2025
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high. The fuel shutoff valves are located inside a deck box on the port/starboard side aft. Mark the deck box indicating the fuel shutoff valves are located inside.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 25 June 2025
Resolution: Owner provided signs on the exterior of the deck boxes.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 June 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. The vessel is not provided with a chart of the intended operating area. Provide the same.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 3 July 2025
Resolution: Owner provided hard copy chart on board vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2025
Resolved
Each lifeline on a ring life buoy must be non-kinking. The provided lifeline is not of the non-kinking type. Provide the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 3 July 2025
Resolution: Owner provided non-kinking life line for ring buoy.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 25 June 2025
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information specific to the individual vessel. Post an emergency broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 June 2025
Resolution: Witnessed proper installation of radio broadcast placard.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 25 June 2025
Resolved
Before getting underway on a voyage or as soon as practicable thereafter the master of a vessel shall ensure that suitable announcements are made informing the passengers of the information required by 46 CFR 185.506(a)(1)-(6). The provided safety orientation script did not contain all of the required information. Provide the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 7 August 2025
Resolution: Witnessed updated safety orientation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2025
Resolved
Each ring buoy floating waterlight must be approved in accordance with 46 CFR 161.010. The floating waterlight is not provided with the manufacturer recommended batteries. Install the same. The vessel is limited to daylight operations until complete.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2025
Resolved 3 July 2025
Resolution: Owner provided the appropriate AA lithium batteries recommended by the manufacturer.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2025
Resolved
Electrical equipment installed on a vessel must be installed and maintained to protect passengers and crew from electrical hazards. There are four(4) open spaces on the electrical distribution panel, port side, aft. Provide blanks for the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 7 August 2025
Resolution: Witnessed installation of blanks for four open spaces.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2025
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. The vessel's ring life buoy does not contain retroreflective material. Provide the same.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 7 August 2025
Resolution: Witnessed satisfactory installation of retro-reflective material.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 25 June 2025
Resolved
The Master and crew of a vessel will be familiar with the content of and have mounted at the operating station emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. The provided Emergency Instructions were incomplete and were not posted. Provide complete emergency instructions and post the same at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 7 August 2025
Resolution: Witnessed posting of complete emergency instructions at the operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 June 2025
Resolved
On a vessel of at least 26 feet in length a visual and audible alarm must be provided at the operating station to indicate high water level. The provided bilge alarm is integrated with the indicator light for the automatic bilge pump. In this configuration, the high water alarms can only be activated if the automatic bilge pumps are in the "Auto" mode and could potentially be turned off if the switch is in the "off" position. Provide separate bilge high water alarms for the port and starboard pontoons.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 7 August 2025
Resolution: Owner installed separate audible and visual high water alarms for both port and starboard hull. Witnessed satisfactory operation of the same.