C-PIONEER

C-PIONEER is a 2001 industrial vessel. The Coast Guard has recorded 50 inspections since 2000, most recently in April 2026, along with 37 deficiencies — 1 with no resolution recorded —, 1 operational control and 3 casualty investigations between 2023 and 2025.

Records from 2000 to 2026. Most recent: inspection, 14 April 2026.

Built
2001
Last inspected
14 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9245940 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDA3356
Flag
UNITED STATES
368346980
Maury page id
psix-18508

Inspections, by type

…with no type recorded9
…past their stated due date1
Years with a record 19 calendar years (2000–2026)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)240.5 ft × 56.0 ft × 21.0 ft
Registered tonnagegross 2,934 / net 880
ITC dimensions (L × B × D)240.5 ft × 56.0 ft × 21.0 ft
ITC tonnagegross 2,934 / net 880
BuilderNORTH AMERICAN FABRICATORS LLC · LAROSE, LA, UNITED STATES · built 2001
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 May 2026 · expires 30 June 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5259 - Displacement, Ton
3507 - Dead Weight, Ton
2934 - Convention (Subpart B), Gross Ton
880 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP3608MMSI 368346980 · active · compulsorily equipped · granted 29 December 2023, expires 29 December 2033
WDN5589MMSI 368291370 · cancelled · compulsorily equipped · granted 6 January 2023, cancelled 29 December 2023
WDA3356MMSI 338876000 · expired · compulsorily equipped · granted 16 December 2010, cancelled 20 March 2021
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 50

14 April 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8349445
6 September 2025 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 8256291
3 September 2025 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8229216
28 May 2025 Administrative Inspection · Annual Inspection · ACP COI Oversight · COI Inspection · ACP Handover Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8118433
28 April 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8121510
28 April 2025 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8135705
5 November 2024 Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8029639
4 November 2024 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8029545
5 October 2024 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8014795
25 September 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8009441
3 September 2024 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8000567
15 August 2024 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7958616
27 April 2024 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7902462
4 March 2024 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7874125
19 January 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7851741
26 November 2023 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7829559
26 November 2023 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7829857
15 September 2023 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7792346
12 September 2023 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7790317
20 August 2023 Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7772630
12 July 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7742463
6 April 2023 Construction Oversight · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7663943
3 January 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6331989
1 February 2017 MTSA/ISPS Verification · MARPOL Annex VI Survey · Administrative Inspection · COI Inspection · MARPOL Annex IV Survey · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6080783
14 September 2015 COI Inspection · MTSA/ISPS Verification · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex VI Survey · Administrative Inspection · MARPOL Annex IV Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5717784
10 January 2012 Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4222256
15 November 2010 MARPOL Annex IV Survey · MTSA/ISPS Verification · MARPOL Annex I Examination · DAPI Audit · COI Inspection · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3891803
12 January 2009 MTSA/ISPS Verification · Periodic Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3376510
16 September 2008 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3325852
15 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3207143
9 April 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3222298
7 December 2007 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3111081
23 January 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2860366
6 October 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2795049
4 January 2006 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2560333
27 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502024
23 August 2005 Internal Structural Exam · Cargo Tank Internal · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2474551
24 March 2005 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2307623
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293923
25 October 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2227837
27 September 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2213333
12 January 2004 Cargo Tank Internal · Internal Structural Exam · Underwater Inspection in lieu of Drydock · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1981831
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976822
14 March 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1757179
21 March 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1495425
25 November 2001 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1479276
22 May 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1063570
17 January 2001 Initial Certification · Initial Construction-Excluding Oversight · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361941
1 October 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1053699
31 March 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050080

Deficiency record · 37

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 May 2025 Resolved
The inspection for certification is made by a marine inspector to determine whether the vessel is in a safe and seaworthy condition, port generator fuel piping found cracked, and in need of replacement.
Action required: 10 - Deficiency Rectified
Resolved 28 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 May 2025 Resolved
The inspection for certification is made by a marine inspector to determine whether the vessel is in a safe and seaworthy condition Z-drives and thrusters found to have excessive oil leaks, leaked oil to be properly cleaned and area to be made safe.
Action required: 10 - Deficiency Rectified
Resolved 28 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2025 Resolved
The owner or operator of an OSV shall make the vessel available for inspection by a marine inspector each time a defect is discovered that affects the safety of the vessel; or the effectiveness of its equipment; or whenever any important repairs or renewals are made. The inspection is to ensure that the necessary repairs or renewals have been effectively made and the material and workmanship used to accomplish the repairs or renewals are satisfactory. The vessel reported the stbd main diesel engine shaft coupling failed and the engine is shut down. Determine cause and affect repairs to the satisfaction to the Coast Guard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2025
Resolved 29 April 2025
Resolution: Replaced with new
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 November 2024 Resolved
A survey shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or whenever any important repairs or renewals are made. Vessel reported an oil sheen in the vicinity of the forward SDT. Determine cause and affect repairs to the satisfaction of the Coast Guard, prior to continued operations. One time transit to shipyard in NY authorized.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 November 2024
Resolved 9 November 2024
Resolution: Gasket for swing down thruster replaced & conducted sat sea trial. No sheen noted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 September 2024 Resolved
The owner or operator of an OSV shall make the vessel available for inspection by a marine inspector each time a defect is discovered that affects the safety of the vessel; or the effectiveness of its equipment; or whenever any important repairs or renewals are made. The inspection is to ensure that the necessary repairs or renewals have been effectively made and the material and workmanship used to accomplish the repairs or renewals are satisfactory. The vessel reported that the swing down thruster is not operational and is stuck in the down position. Determine cause and affect repairs to the satisfaction to the Coast Guard and American Bureau of Shipping (ABS).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2024
Resolved 26 September 2024
Resolution: See Activity Number 8009441.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 August 2024 Resolved
Visual alarms must initially indicate the equipment or system malfunction without operator intervention. Stbd Low L/O, Port & Stbd Generator overspeed indicator lights were providing visual indication engine condition as designed.
Action required: 10 - Deficiency Rectified
Resolved 15 August 2024
Resolution: Vessel Rep provied evidence of properly operating machinery indicating lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 April 2024 Resolved
When the cognizant OCMI deems inspection necessary, the repairs or alterations must be inspected by a marine inspector. Vessel requires repairs to Port MDE/Shaft coupling. CGMI to inspect repairs and witnesses operations prior to departure from port.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 April 2024
Resolution: CGMI & Class attended to inspect repairs and witness operations
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 September 2023 Resolved
The owner or operator of an OSV shall make the vessel available for inspection by a marine inspector — (1) Each time an accident occurs, or a defect is discovered that affects — (i) The safety of the vessel; or (ii) The effectiveness or completeness of its lifesaving, fire-fighting, or other equipment; or (2) Whenever any important repairs or renewals are made. (b) The inspection is to ensure that — (1) The necessary repairs or renewals have been effectively made; (2) The material and workmanship used to accomplish the repairs or renewals are satisfactory; and (3) The OSV complies with the regulations in this subchapter. ***Vessel reported a hydraulic leak from the swing down thruster. Prior to use of the thruster or DP operations, effect repairs to the satisfaction of the attending Coast Guard Marine Inspector.***
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 September 2023
Resolution: See ABS report in MISLE Activity #7792346.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 April 2023 Resolved
At each inspection for certification, the fire main and hoses must be tested. Fire main and hoses could not be tested at the time of the inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 July 2023
Resolved 27 July 2023
Resolution: MI witnessed satisfactory test.
Construction/Loadline › Structures › Door
Issued 1 February 2017 Resolved
WTD from E/R to Tank Farm, WTD from Z-drive to escape truck and hatch from Z drive escape trunk to main deck not operable. Fix closures and prove proper operation to attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2017
Resolved 3 February 2017
Resolution: Closures serviced and proper operation witnessed by inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 1 February 2017 Resolved
Co2 time delays for the engine room and emergency generator room did not have the appropriate delay IAW posted plans or the times stamped on the Delay bottles.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2017
Resolved 3 February 2017
Resolution: Witnessed retest of the delays with satisfactory results.
Lifesaving › Launching Appliances › Davit
Issued 1 February 2017 Resolved
Repair manual release cable and pulleys for lowering the rescue boat.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2017
Resolved 3 February 2017
Resolution: Cable/ pulleys replaced and tested in the presence of USCG Marine Inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 February 2017 Resolved
Replace stern light wiring.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2017
Resolved 3 February 2017
Resolution: Wiring replaced.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 1 February 2017 Resolved
Solenoid valve for # 1 OWS not closing. Correct and prove proper operation to attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 3 February 2017
Resolution: Debris found/removed from valve. Marine inspector witnessed a satisfactory test.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 1 February 2017 No resolution recorded
PRV’s for the Dry Bulk tanks were painted and no test documentation available. Remove paint and bench test prior to using the Dry Bulk system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2017 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 February 2017 Resolved
Circuit breaker indicator light for the port generator breaker did not illuminate. Correct to the satisfaction to the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 3 February 2017
Resolution: Bulb replaced and verified by USCG Marine Inspector
Fire Fighting › Fire Hydrants › Condition
Issued 1 February 2017 Resolved
Valve on bridge wing leaking by.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 3 February 2017
Resolution: Seat cleaned and tested satisfactory.
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 1 February 2017 Resolved
Searchlight inoperable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 3 February 2017
Resolution: Verified operation
Lifesaving › Rescue Boat Equipment › Radar Reflector
Issued 1 February 2017 Resolved
Radar reflector broken
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 3 February 2017
Resolution: Replaced.
Lifesaving › Rescue Boat Equipment › Instructions (engine start/operation)
Issued 1 February 2017 Resolved
Replace kill switch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 3 February 2017
Resolution: Replaced
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 February 2017 Resolved
Annual window expired 21DEC16, vessel operated without renewing COI until 01FEB17.
Due 1 February 2017
Resolved 1 February 2017
Resolution: Completed COI exam.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 December 2010 Resolved
Provide a third party test and inspection report for the vessels CO2 systems to include test of the time delay, alarms and shutdowns.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2010
Resolution: System was tested and inspected and found to be operating SAT.
Engineering › Fuel Oil Service System › Hose
Issued 2 December 2010 Resolved
Remove jury rigged f/o hoses from f/o purifier to f/o tank. Hoses are over 30" in lengh.
Condition: Placed in Improper Service
Due 9 December 2010
Resolved 2 December 2010
Resolution: Hoses removed and purifier placed back in normal service.
Documentation › Logs/Records › Record Book of Engine Parameters
Issued 2 December 2010 Resolved
Provide a third party automation test report for all required automated equipment.
Due 2 January 2011
Resolved 14 December 2010
Resolution: Received automation test report.
Fire Fighting › Fire Main › Valves
Issued 7 December 2007 Resolved
Replace fire pump relief valve on the discharge side of the pump with a 150 psi max relief valve.
Due 21 December 2007
Resolved 14 December 2007
Fire Fighting › Structural - A Class Divisions › Doors
Issued 23 January 2007 Resolved
Properly adjust aft engine room watertight door to allow self-closing device to work properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2007
Resolution: Cheif Engineer adjusted door.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 23 January 2007 Resolved
Personnel assigned to wear fireman's outfit too large for existing protective clothing. Personnel temporarily assigned whose body size allows use of existing equipment. Vessel master ordering 2XL protective clothing for fireman's outfit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2007
Resolution: Personnel reassigned temporarily until proper size clothing is acquired.
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 4 January 2006 Resolved
Provide Rescue boat equipment IAW SOLAS.
Condition: Improper/Lack of Maintenance
Due 4 February 2006
Resolved 9 February 2006
Resolution: Renewed Cable.
Accommodation/Occupational Safety › Ventilation › General
Issued 12 January 2004 Resolved
Reconfigure ventilation system located in the air conditioning space containing batteries. LEGACY COMPONENT DESC: Battery space ventilation
Action required: 705 - Other - as specified
Due 12 February 2004
Resolved 24 March 2005
Communications › Radio Communications › EPIRB
Issued 14 March 2003 Resolved
REPAIR EPIRB ANTENNA.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2003
Resolved 14 March 2003
Communications › Radio Communications › EPIRB
Issued 14 March 2003 Resolved
RENEW OUTDATED EPIRB HYDROSTATIC RELEASE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2003
Resolved 14 March 2003
Electrical › Electrical Distribution System (emergency)
Issued 14 March 2003 Resolved
PROVIDE PROPER LOCATION FOR CHARGING AND STOWAGE OF BATTERIES LOCATED IN THE 02 LEVEL A/C SPACE. LEGACY COMPONENT DESC: BATTERY INSTALLATION
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2003
Resolved 12 January 2004
Resolution: 835 cleared due to appeal by Edision Chouest management. 835 appeal granted by [name withheld]8.
Fire Fighting › Firemans Outfit › Lantern (Electric Safety Lamp)
Issued 21 March 2002 Resolved
PROVIDE FLASHLIGHT AND BATTERIES FOR FIREMANS SUITS
Condition: Unknown
Due 21 March 2002
Resolved 21 March 2002
Electrical › Electrical Distribution System (service)
Issued 21 March 2002 Resolved
REPALCE BURNED BULBS ON BRIDGE ALARM PANEL LEGACY COMPONENT DESC: ALARMS
Condition: Improper/Lack of Maintenance
Due 21 March 2002
Resolved 21 March 2002
Pollution Prevention/Response › Prevention Equipment
Issued 21 March 2002 Resolved
POST TRANSFER PROCEDURES FOR LIQUID MUD AND FUEL OIL AT THE TRANSFER STATIONS. LEGACY COMPONENT DESC: TRANSFER PROCEDURES
Due 21 March 2002
Resolved 28 March 2002
Fire Fighting › Fire Pumps › Pressure
Issued 21 March 2002 Resolved
REPAIR FIREMAIN RELIEF VALVE TO OPERATE AT NO MORE THAN 125PSI
Condition: Improper/Lack of Maintenance
Due 21 March 2002
Resolved 21 March 2002
Unknown
Issued 17 January 2001 Resolved
Provide status on plan review to Sub "I"._x001C_ _x001C_ Vessel will be Certificated as Multi-Svc vessel when completed.
Condition: Unknown
Due 17 January 2001
Resolved 17 January 2001

Casualty record · 3

26 November 2023Routine · role: Involved in a Marine Casualty · activity 7829857
28 April 2025Routine · role: Involved in a Marine Casualty · activity 8135705
6 September 2025Routine · role: Involved in a Marine Casualty · activity 8256291
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.