MAURY USCG vessel records
← All vessels

IPSARION

IPSARION is a 2024 freight ship. The Coast Guard has recorded 2 inspections since 2024, most recently in August 2025, along with 1 deficiency.

Records from 2024 to 2025. Most recent: inspection, 4 August 2025.

Built
2024
Last inspected
4 August 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 August 2025
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2024–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9985655
9HA6085
1851742
Flag
MALTA
Maury page id
psix-1851742

Documentation record

Tonnage as PSIX records it36560 - Regulatory (Subpart C or D), Gross Ton
66685 - Dead Weight, Ton
77937 - Displacement, Ton
22520 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

4 August 2025 COE-Administrative
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8203097
12 December 2024 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8046572

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 December 2024 Resolved
MAINTENANCE, TESTING, AND INSPECTIONS SHALL BE CARRIED OUT BASED ON THE GUIDELINES DEVELOPED BY THE ORGANIZATION AND IN A MANNER HAVING DUE REGARD TO ENSURING THE RELIABILITY OF THE FIRE FIGHTING SYSTEM AND APPLIANCES. PSCO OBSERVED CREW UNABLE TO PROPERLY TEST FLAME DETECTORS DUE TO LACK OF CORRECT TESTING EQUIPMENT. 74SOLAS(2020) II-2/14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2024

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.