ISLAND RUNNER

ISLAND RUNNER is a 1980 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1985, most recently in March 2025, along with 35 deficiencies.

Records from 1985 to 2025. Most recent: inspection, 7 March 2025.

Built
1980
Last inspected
7 March 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH8959
185375
Flag
UNITED STATES
367663240
Maury page id
psix-185375

Inspections, by type

…with no type recorded4
Years with a record 37 calendar years (1985–2025)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.6 ft × 17.0 ft × 7.7 ft
Registered tonnagegross 57 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1980
Hull materialAluminum
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH8959MMSI 367663240 · active · compulsorily equipped · granted 12 March 2025, expires 24 March 2035
WAD7795MMSI 366960720 · expired · compulsorily equipped · granted 30 June 2004, cancelled 4 October 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SARA D Passenger (Inspected) · MISLE 49819 · 17 April 2002 · activity 1612054

Inspection history · 57

7 March 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8090199
3 June 2024 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7925886
5 September 2023 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7784860
19 July 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7746500
23 June 2022 Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7443951
5 August 2021 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7256333
1 July 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7206783
24 March 2020 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6916473
6 June 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6706055
5 July 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6458303
10 August 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6229767
11 April 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6118964
14 April 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5851281
6 March 2014 Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4805542
3 July 2012 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4356623
2 September 2010 Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 3840131
25 March 2010 DAPI Audit · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3698881
10 December 2009 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 3650526
20 April 2009 Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3456588
12 August 2008 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3289560
10 September 2007 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3054236
31 May 2007 Hull Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2940109
14 September 2006 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2775796
24 May 2005 COI Inspection · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2366600
21 January 2004 Hull Examination · Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1988807
29 May 2003 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1804143
18 April 2002 Examination of Repairs · Damage Survey
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1606687
17 April 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1612054
25 February 2002 COI Inspection · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1488949
29 March 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459684
3 February 2000 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1427779
14 April 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1395162
23 January 1998 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1418289
19 February 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435867
11 September 1996 Excursion Permit
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1266117
18 March 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1390223
22 February 1996 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380414
11 September 1995 Excursion Permit
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1371160
31 March 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1390026
15 March 1994 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463077
13 September 1993 Excursion Permit
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1146968
22 March 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 835404
12 March 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1149194
5 March 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438031
9 September 1992 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1248602
8 September 1992 Excursion Permit
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1265923
6 May 1992 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1258559
24 March 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 950393
12 September 1991 Excursion Permit
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 937925
15 February 1991 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1229206
12 September 1990 Re-Inspection · Excursion Permit
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 915233
9 August 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1341621
27 June 1989 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1197012
8 February 1988 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017551
3 February 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017165
2 October 1986 Re-Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326859
11 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289860

Deficiency record · 35

03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 June 2024 Resolved
Except as otherwise provided in the section, rail or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. Vessel did not have the poles and chains for the aft deck on board to provide equivalent protection. 46CFR177.35-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2024
Resolution: Pictures sent of deck chains.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 3 June 2024 Resolved
Vessel must comply with applicable requirements for any radio and EPRIB installations, as set forth in 47 CFR Part 80. Master only had a Restricted Radio Operators Permit, not a Marine Radio Operators Permit as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2024
Resolved 13 March 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 June 2024 Resolved
Vessel must be operated in accordance with applicable law and regulations to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel only had three days in March 2024 for the ships log and did not have steering gear, controls and communication system checks; EPIRB; Drills; Lifesaving maintenance; and Firefighting maintenances logged for the year nor prior to getting underway. 705 - until next inspection.
Action required: 705 - Other - as specified
Resolved 13 March 2025
Resolution: Vessel has not been operating. Had them log the pre-departure and drills we conducted. They have logging monthly checks, since last inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 June 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Port running light was inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 July 2022
Resolution: Port nav light replaced and tested to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 June 2022 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Unless otherwise stated in this section, each item of equipment carried, whether required under this section or not, must be secured by lashings, stored in lockers, compartments, brackets, or have equivalent mounting or storage arrangements that do not: (3) Interfere with launching, recovery, or rescue operations Bitter end of lifeline rigging for life floats was improperly arranged.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 July 2022
Resolution: Bitter end of lifeline rigging for life floats configured to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 June 2022 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel did not have fire buckets on board.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 July 2022
Resolution: MI verified buckets onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 June 2022 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Fuel tank goose necks did not have flame screens installed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 July 2022
Resolution: Verified Mesh flame screens installed on fuel tank vents, and to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2021 Resolved
FLEXIBLE HOSE MAY BE USED PROVIDED IT IS FITTED WITH SUITIBLE CONNECTIONS FITTINGS AND HAS HIGH RESISTANCE TO SALTWATER, PERTOLEUM OILS AND VIBRATION. BOTH MDE'S FUEL HOSES SHOWED SIGNS OF WEAR/LEAKAGE. 46 CFR 182.20-40(2) 60 C
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 August 2021
Resolution: 8/23/221- recieved email containing photos as prrof of repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 August 2021 Resolved
EACH HATCH EXPOSED TO THE WEATHER MUST BE WATERTIGHT; EXCEPT THAT THE FOLLOWING HATCHES MAY BE WEATHERTIGHT...EACH HATCH ON A VESSEL THAT OPERATES ONLY ON PROTECTED WATERS. FORWARD AND AFT MANHOLE HATCHES NEEDED TO BE ADJUSTED AND STBD CABIN DOOR MISSING 6" OF GASKET MATERIAL. 46 CFR 171.124(a) (3) 60 C
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 August 2021
Resolution: 8/23/221- recieved email containing photos as prrof of repairs.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 June 2019 Resolved
Vessel's VHG/DSC Radios must have GPS input and MMSI data programmed in to satisfaction of CG Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
Resolution: Marine Inspector witnessed satisfactory operation of VHF with GPS and MMSI programmed in.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 April 2017 Resolved
FCC Bridge to Bridge certificate is expired.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 20 April 2017
Resolution: Updated certificate provided.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 April 2017 Resolved
Emergency lighting in berthing area was not operating.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 20 April 2017
Resolution: E-lighting was fixed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2017 Resolved
Broken hose clamp on water line feeding port side wet exhaust.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 20 April 2017
Resolution: Hose clamp was replaced.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 11 April 2017 Resolved
EAP hotline number posted on vessel wasn't working.
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 20 April 2017
Resolution: Updayed EAP number was posted.
Electrical › Electric Supply System (service) › Cable
Issued 14 April 2016 Resolved
Install light or over exposed wiring on light socket above bunk in forward accommodation space.
Due 14 May 2016
Resolved 26 April 2016
Resolution: Lighting repaired to the satisfaction of the MI.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 April 2016 Resolved
Install missing smoke detector in forward accommodation space
Due 14 May 2016
Resolved 26 April 2016
Resolution: Smoke detector installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 April 2016 Resolved
Remove multi-outlet (powerstrip) by bridge way
Due 14 May 2016
Resolved 26 April 2016
Resolution: Multi outlet removed.
Documentation › Logs/Records › Drug Test Records
Issued 14 April 2016 Resolved
Provide drug testing plan/evidence of compliance with DAPI requirements
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 25 April 2016
Resolution: Company provided copy of plan and testing records.
Engineering › Steering Gear System › Power Unit
Issued 21 April 2009 Resolved
Replace wasted/corroded hydraulic wire connections in aft steering.
Action required: 705 - Other - as specified
Due 28 April 2009
Resolved 5 May 2009
Resolution: Conducted satisfactory inspection of new hydraulic connections in aft steering.
Engineering › Fuel Oil Service System › Valve
Issued 21 April 2009 Resolved
Replace turn handle on forward engine room emergency fuel shut-off valves.
Action required: 705 - Other - as specified
Due 28 April 2009
Resolved 5 May 2009
Resolution: Completed satisfactory inspection of turn handles on E/R fuel shut off valves.
Engineering › Bilge Water Management System › Not Operational
Issued 21 April 2009 Resolved
Replace all bilge alarms (visual and audible) prior to carrying passengers.
Action required: 705 - Other - as specified
Due 28 April 2009
Resolved 5 May 2009
Resolution: Completed satisfactory test of new bilge alarm installation.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 20 April 2009 Resolved
Recharge and service 2 fire extinguishers prior to carrying passengers.
Action required: 705 - Other - as specified
Due 28 April 2009
Resolved 5 May 2009
Resolution: Completed satisfactory inspection of 2 portable fire extinguishers.
Engineering › Fuel Oil Service System › Tank
Issued 14 September 2006 Resolved
Prior to sailing, empty, certify as safe for hot work, and affect permanent repairs to the aft fuel tank located in the Lazarrette (leak at bottom, port side). Tank is to be tested in the presence of a CG marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2006
Stability › Watertight Integrity › General
Issued 14 September 2006 Resolved
Prior to sailing, install an approved bulkhead connection for the A/C condenser suction line (hose is currently routed through a non-tight sleeve).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2006
Construction/Loadline › Hull › Side Shell
Issued 14 September 2006 Resolved
Affect weld repairs, as marked, the hull in the lazarrette (port side in way of corner).
Due 14 October 2006
Resolved 19 September 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 September 2006 Resolved
Affect weld repairs, as marked, to the exhaust piping in the Lazarrette (port M/E - fwd bulkhead, stbd M/E - transom).
Due 14 October 2006
Resolved 19 September 2006
Stability › Watertight Integrity › General
Issued 14 September 2006 Resolved
Make all bulkhead penetrations watertight (miscellaneous cable and control penetrations).
Due 14 October 2006
Resolved 19 September 2006
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 14 September 2006 Resolved
Affect repairs to drain piping (wasted through).
Due 14 October 2006
Resolved 19 September 2006
Stability › Watertight Integrity › General
Issued 14 September 2006 Resolved
Renew engine room hatch gaskets and dogging bolts for both hatches.
Due 14 October 2006
Resolved 19 September 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 September 2006 Resolved
Properly secure the head door (missing handle/latch).
Due 14 October 2006
Resolved 19 September 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 February 2002 Resolved
The junction/switch box that held the controls to flush the toilet was wasted and held together with duct tape.
Condition: Improper/Lack of Maintenance
Due 26 February 2002
Resolved 26 February 2002
Resolution: Vessel rep replaced box during course of inspection.
Engineering › Steering Gear System › Rudder
Issued 25 February 2002 Resolved
The vessels starboard rudder was found to have a cracked weld where it conects to the rudder post.
Due 26 February 2002
Resolved 26 February 2002
Resolution: Vessel rep ground and re-welded the cracked weld.
Accommodation/Occupational Safety
Issued 22 February 1996 Resolved
REPAIR/REPLACE SEWAGE HOLDING TANK LEVEL INDICATOR.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Accommodation/Occupational Safety
Issued 22 February 1996 Resolved
PREPARE SEWAGE PIPING FOR CG INSPECTION (SUSPECTED LEAK AT "T" JOINT); RUN SEWAGE PUMP IN PRESENCE OF CG INSPECTOR TO CHECK FOR LEAKS.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Accommodation/Occupational Safety
Issued 22 February 1996 Resolved
REPAIR/REPLACE SEWAGE PUMP.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.