Records from 2016 to 2025. Most recent: inspection, 7 March 2025.
Documentation record
Registered dimensions (L × B × D)61.6 ft × 17.0 ft × 7.7 ft
Registered tonnagegross 57 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1980
Hull materialAluminum
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
7 March 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8090199
3 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7925886
5 September 2023
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7784860
19 July 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7746500
23 June 2022
Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7443951
5 August 2021
Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7256333
1 July 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7206783
24 March 2020
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6916473
6 June 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6706055
5 July 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6458303
10 August 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6229767
11 April 2017
Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6118964
14 April 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5851281
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 June 2024
Resolved
Except as otherwise provided in the section, rail or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. Vessel did not have the poles and chains for the aft deck on board to provide equivalent protection. 46CFR177.35-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2024
Resolution: Pictures sent of deck chains.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 3 June 2024
Resolved
Vessel must comply with applicable requirements for any radio and EPRIB installations, as set forth in 47 CFR Part 80. Master only had a Restricted Radio Operators Permit, not a Marine Radio Operators Permit as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2024
Resolved 13 March 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 June 2024
Resolved
Vessel must be operated in accordance with applicable law and regulations to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel only had three days in March 2024 for the ships log and did not have steering gear, controls and communication system checks; EPIRB; Drills; Lifesaving maintenance; and Firefighting maintenances logged for the year nor prior to getting underway. 705 - until next inspection.
Action required: 705 - Other - as specified
Resolved 13 March 2025
Resolution: Vessel has not been operating. Had them log the pre-departure and drills we conducted. They have logging monthly checks, since last inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 June 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
Port running light was inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 July 2022
Resolution: Port nav light replaced and tested to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 June 2022
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Unless otherwise stated in this section, each item of equipment carried, whether required under this section or not, must be secured by lashings, stored in lockers, compartments, brackets, or have equivalent mounting or storage arrangements that do not: (3) Interfere with launching, recovery, or rescue operations
Bitter end of lifeline rigging for life floats was improperly arranged.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 July 2022
Resolution: Bitter end of lifeline rigging for life floats configured to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 June 2022
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Vessel did not have fire buckets on board.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 July 2022
Resolution: MI verified buckets onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 June 2022
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements.
Fuel tank goose necks did not have flame screens installed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 July 2022
Resolution: Verified Mesh flame screens installed on fuel tank vents, and to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2021
Resolved
FLEXIBLE HOSE MAY BE USED PROVIDED IT IS FITTED WITH SUITIBLE CONNECTIONS FITTINGS AND HAS HIGH RESISTANCE TO SALTWATER, PERTOLEUM OILS AND VIBRATION. BOTH MDE'S FUEL HOSES SHOWED SIGNS OF WEAR/LEAKAGE.
46 CFR 182.20-40(2)
60 C
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 August 2021
Resolution: 8/23/221- recieved email containing photos as prrof of repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 August 2021
Resolved
EACH HATCH EXPOSED TO THE WEATHER MUST BE WATERTIGHT; EXCEPT THAT THE FOLLOWING HATCHES MAY BE WEATHERTIGHT...EACH HATCH ON A VESSEL THAT OPERATES ONLY ON PROTECTED WATERS. FORWARD AND AFT MANHOLE HATCHES NEEDED TO BE ADJUSTED AND STBD CABIN DOOR MISSING 6" OF GASKET MATERIAL.
46 CFR 171.124(a) (3)
60 C
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 August 2021
Resolution: 8/23/221- recieved email containing photos as prrof of repairs.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 June 2019
Resolved
Vessel's VHG/DSC Radios must have GPS input and MMSI data programmed in to satisfaction of CG Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
Resolution: Marine Inspector witnessed satisfactory operation of VHF with GPS and MMSI programmed in.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 April 2017
Resolved
FCC Bridge to Bridge certificate is expired.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 20 April 2017
Resolution: Updated certificate provided.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 April 2017
Resolved
Emergency lighting in berthing area was not operating.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 20 April 2017
Resolution: E-lighting was fixed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2017
Resolved
Broken hose clamp on water line feeding port side wet exhaust.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 20 April 2017
Resolution: Hose clamp was replaced.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 11 April 2017
Resolved
EAP hotline number posted on vessel wasn't working.
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 20 April 2017
Resolution: Updayed EAP number was posted.
Electrical › Electric Supply System (service) › Cable
Issued 14 April 2016
Resolved
Install light or over exposed wiring on light socket above bunk in forward accommodation space.
Due 14 May 2016
Resolved 26 April 2016
Resolution: Lighting repaired to the satisfaction of the MI.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 April 2016
Resolved
Install missing smoke detector in forward accommodation space
Due 14 May 2016
Resolved 26 April 2016
Resolution: Smoke detector installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 April 2016
Resolved
Remove multi-outlet (powerstrip) by bridge way
Due 14 May 2016
Resolved 26 April 2016
Resolution: Multi outlet removed.
Documentation › Logs/Records › Drug Test Records
Issued 14 April 2016
Resolved
Provide drug testing plan/evidence of compliance with DAPI requirements
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 25 April 2016
Resolution: Company provided copy of plan and testing records.