MAURY USCG vessel records
← All vessels

CHINA ENERGY

CHINA ENERGY is a freight ship. The Coast Guard has recorded 1 inspection in 2025, along with 4 deficiencies.

Records in 2025. Most recent: inspection, 25 February 2025.

Built
Not recorded
Last inspected
25 February 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 February 2025
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9495064
1854976
Flag
HONG KONG
Maury page id
psix-1854976

Documentation record

Tonnage as PSIX records it64123 - Convention (Subpart B), Gross Ton
114600 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

25 February 2025 Administrative Inspection · PSC A · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8083883

Deficiency record · 4

09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 25 February 2025 Resolved
The means of embarkation required in paragraph 1 shall be constructed and installed based on the guidelines developed by the organization. PSCO observed missing cotter pin on bolts securing STBD gangway to embarkation point. 74SOLAS(24)II-1/3-9 MSC.1/CIRC 1331
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2025
Resolution: Received Class report. All sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other cargo/timber/deck/construction
Issued 25 February 2025 Resolved
Bulk carriers shall comply with the maintenance requirement provided in standards for owner’s inspection and maintenance of bulk carrier hatch covers. PSCO observed hydraulic leak from cargo hold 3 hatch cover, holds 4 & 6. 74SOLAS(24)XII/7.2 MSC 169(79)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2025
Resolution: Receievd Class report. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 25 February 2025 Resolved
All engines in rescue boats shall demonstrate that the gearbox and gearbox train are engaging satisfactorily. Helm station throttle not able to shift gears. 74SOLAS(24) III/20.6.2
Action required: 10 - Deficiency Rectified
Resolved 25 February 2025
Resolution: PSCO observed shift cable being re-attached. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 February 2025 Resolved
Paint lockers shall be protected by a sprinkler system. PSCO observed 02 buckets under 02 sprinkler heads. 74SOLAS(24) II-2/10.6.3.1.3
Action required: 10 - Deficiency Rectified
Due 25 February 2025
Resolved 25 February 2025

Ownership record