← All vessels
TAO ACE
TAO ACE is a freight ship. The Coast Guard has recorded 3 inspections in 2025, along with 2 deficiencies.
Records in 2025. Most recent: inspection, 6 April 2025.
- Built
- Not recorded
- Last inspected
- 6 April 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 2 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9639696 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FQQ6
1854987
Flag
PANAMA
—
Maury page id
psix-1854987
Inspections, by type
…with no type recorded1
Years with a record
1 calendar year (2025)
The 3 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it15289 - Regulatory (Subpart C or D), Gross Ton
8932 - Regulatory (Subpart C or D), Net Ton
8932 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 3
6 April 2025
COE-Administrative
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8106871
8 February 2025
PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8075116
6 February 2025
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8076256
Deficiency record · 2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 February 2025
Resolved
07199- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without damage to the ship or persons onboard. Interior walls are to be protected with insolated fire brick/ refractory and a cooling system. PSCO observed a large crack that went all the way through the left side refractory of the incinerator.
-74 SOLAS (20) 1/11
-MEPC. 244(66)/3.1
-40ac
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 8 February 2025
Resolved
The Secretary may order any vessel, in a port or place subject to the jurisdiction of the United States or in the navigable waters of the United States, to operate or anchor in a manner the Secretary directs if the Secretary has reasonable cause to believe such vessel does not comply with any regulation issued under section 70034 or any other applicable law or treaty.
Hot and cold running fresh water must be available in all wash places. PSCO observed that the shared water closet in the crew accommodation areas had a sink with only one valve that was capable of delivering cold water only.
-46 U.S.C. 70002
-ILO 147/72.6
-40ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.