This record may be incomplete: the most recent inspection recorded for this vessel was 13 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it52 - Regulatory (Subpart C or D), Gross Ton 35 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 29 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Ring buoy did not meet CG requirement for tow vessel IAW 46 CFR 25.25-5(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2008
Resolved 20 March 2008
Resolution: Coast Guard approved ring buoy now on board vessel
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 20 March 2008Resolved
Exposed panel in circuit breaker box in galley area needs to be covered/blanked off IAW Good Marine Practice
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2008
Resolved 24 April 2008
Resolution: Examined by USCG inspector.
Fire Fighting › Remote Fuel Shutoff › General
Issued 20 March 2008Resolved
Remote fuel oil shutoffs need to be labeled properly "port fuel tank, starboard fuel tank" and operating instructions on main engine pull need minimum "1 inch lettering" IAW 46 CFR 27.207
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2008
Resolved 24 April 2008
Resolution: Examined by USCG inspector.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 26 February 2007Resolved
Vessel name and Hailing Port not displayed on Stern per 46 CFR 67.123
Condition: Improper/Lack of Maintenance
Due 28 March 2007
Resolved 19 November 2007
Resolution: Name and port displayed on stern
Fire Fighting › Fire Hoses › Condition
Issued 26 February 2007Resolved
No fire hose for portable fire pump per 46 CFR 27.301
Condition: Improper/Lack of Maintenance
Due 28 March 2007
Resolved 19 November 2007
Resolution: New 50'' fire hose has been installed with nozzle
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 26 February 2007Resolved
No audible alarm in fire detection panel per 46.CFR 27.203
Condition: Improper/Lack of Maintenance
Due 28 March 2007
Resolved 29 November 2007
Resolution: Audible alarm works in panel
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 26 February 2007Resolved
Control panel improperly marked . Zones need to be separated between engine room and generator room per 46 CFR 27.203.
Condition: Improper/Lack of Maintenance
Due 28 March 2007
Resolved 29 November 2007
Resolution: Panel has properly marked zones
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 February 2007Resolved
Remote fuel shut-off valve not properly marked per 46 CFR 27.207
Condition: Improper/Lack of Maintenance
Due 28 March 2007
Resolved 19 November 2007
Resolution: posted signs at pull stations for remote fuel valves
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 February 2007Resolved
Remote fuel shut-off not located at tank per 46 CFR 27,207
Condition: Improper Installation
Due 28 March 2007
Resolved 19 November 2007
Resolution: Remote fuel shut off valves have been installed at tank and operate properly
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 February 2007Resolved
Radio in wheelhouse wiring needs to be organized good marine practice
Condition: Improper/Lack of Maintenance
Due 28 March 2007
Resolved 19 November 2007
Resolution: Wiring has been redone and organized
Navigation › Piloting/Steering › Magnetic Compass
Issued 26 February 2007Resolved
Magnetic compass not illuminated per 33 CFR 764.72(a)(4)
Condition: Improper/Lack of Maintenance
Due 28 March 2007
Resolved 19 November 2007
Resolution: lighted magnetic compass has been installed in the pilot house
Condition: Improper/Lack of Maintenance
Due 28 March 2007
Resolved 19 November 2007
Resolution: Fog horn was tested, all SAT
Navigation › Piloting/Steering › Magnetic Compass
Issued 30 January 2006Resolved
The magnetic compass is missing a light bulb required for night time illumination.
Condition: Improper Installation
Due 27 February 2006
Resolved 21 February 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 30 January 2006Resolved
Fire extinguisher in the generator room needs to be mounted in its approved bracket.
Condition: Improper Installation
Due 27 February 2006
Resolved 21 February 2006
Fire Fighting › Fixed Fire Detection System › Approval
Issued 30 January 2006Resolved
Need to provide certification of the fixed fire detection system.
Condition: Unknown
Due 16 February 2006
Resolved 21 February 2006
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.