Inspection history · 34
5 June 2025
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8153066
26 March 2024
Deficiency Check · Annual Inspection · Excursion Permit
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7885167
17 March 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7652397
9 March 2023
Excursion Permit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7648196
10 June 2022
Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7479130
9 May 2022
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7443055
20 April 2022
Excursion Permit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7434727
1 November 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7343434
23 April 2020
Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6943080
5 December 2017
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6341957
28 April 2016
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5865570
18 November 2015
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5766807
27 March 2015
Damage Survey · Administration · Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5091755
26 March 2015
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5095171
15 November 2014
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5025027
12 July 2011
Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4079080
16 June 2010
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3768208
23 March 2010
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3702671
1 February 2010
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4007320
4 November 2009
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3628351
29 July 2008
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3285127
10 December 2006
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2853526
28 October 2006
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2822112
28 July 2006
MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2727797
8 June 2006
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2674089
30 March 2005
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2329294
15 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1992925
29 October 2002
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1697938
10 March 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1493444
7 January 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 33531
29 March 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 109971
7 January 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 411647
6 November 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 125343
14 January 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 313842
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 April 2024
Resolved
Emergency lighting in 2nd deck passageway not operable
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2024
Resolved 16 April 2024
Resolution: replaced light
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 April 2024
Resolved
The ring buoy on the starboard side pilothouse was not stenciled with the vessel's name.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2024
Resolved 16 April 2024
Resolution: Stencilled
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 April 2024
Resolved
The fire detection system was not operating properly on the battery backup.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2024
Resolved 24 April 2024
Resolution: Had fire technician come our and service system
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 April 2024
Resolved
2 relief valves on 2 air tanks in the engine room were painted over. replace relief valves
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2024
Resolved 24 April 2024
Resolution: replaced relief valves
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 6 April 2024
Resolved
Drill forms did not have description of drill performed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2024
Resolved 24 April 2024
Resolution: Updated drill forms to include description
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 March 2023
Resolved
46 CFR 140.435
First aid equipment.
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2023
Resolved 19 April 2023
Resolution: Replaced first aid kit
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2023
Resolved
46 CFR 143.205 General.
(a) Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Starboard main engine jacket water pipe was leaking some water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2023
Resolved 19 April 2023
Resolution: Starboard main engine jacket water pipe was replaced.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 March 2023
Resolved
46 CFR 142.220
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following:
(a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Bilges were found to be full of oil and debris.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2023
Resolved 19 April 2023
Resolution: Bilges were cleaned from debris.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 May 2022
Resolved
46 CFR 142.240
Inspection and testing. All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months, as prescribed in paragraphs (a)(1) through (8) of this section, or more frequently if otherwise required by the TSMS applicable to the vessel.
(ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 10 June 2022
Resolution: Monthly inspections being conducted
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 9 May 2022
Resolved
46 CFR 141.360
(c) Lifebuoys must have the following attachments and fittings:
(1) At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. If more than one lifebuoy is carried, at least one must not have a lifeline attached. Port and STBD need to be attached in accordance with the regulations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 10 June 2022
Resolution: Lines attached around the body of the lifebuoy
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 May 2022
Resolved
(c) Lifebuoys must have the following attachments and fittings: Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. The STBD bridge wing life ring has a broken line, needs to be repaired or replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 10 June 2022
Resolution: Line replaced
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 May 2022
Resolved
46 CFR 67.313
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. COD on board was expired place the new COD.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 10 June 2022
Resolution: Valid COD placed onboard vessel
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 May 2022
Resolved
46 CFR 141.375
(a) Carriage requirement. A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. Flares on board were expired replace with non-expired flares.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 16 June 2022
Resolution: New flares placed onboard vessel
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 May 2022
Resolved
46 CFR 140.420
This includes abandoning the vessel, recovering persons from the water, responding to onboard fires and flooding, or responding to other threats to life, property, or the environment. Provide copy of last fire drill.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 10 June 2022
Resolution: Last 2 fire drill records provided
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2022
Resolved
46 CFR 142.315 (a)(3)(i)
An approved 160-B semi-portable fire-extinguishing system to protect the engine room. Hose on 160-B is unable to reach all areas of the engine room. Relocate to reach all fire hazards in protected space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 10 June 2022
Resolution: 160-B reloacted
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 1 November 2021
Resolved
Fire alarm panel is displaying trouble code and is not functioning properly. Have qualified inspector repair panel and verify proper function prior to movement of vessel. (46CFR142.330)
Action required: 17 - Rectify deficiencies prior to departure
Due 1 November 2021
Resolved 2 November 2021
Resolution: qualified tech repaired panel.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 1 November 2021
Resolved
Vessel does not have proper machinery alarms required. Install and make means to test alarms. Needs: main engine low lubricating oil pressure, main engine high cooling water temp, Aux. gen. engine low lube oil pressure and high cooling water temp, high bilge level, low hydraulic steering fluid level fitted with audible and visual alarm. (46CFR143.230)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2021
Resolved 17 December 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 November 2021
Resolved
Fuel Filter bowl is plastic, needs to be metal in accordance with manufacturers specs. (46CFR142.220)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2021
Resolved 17 December 2021
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 1 November 2021
Resolved
Bilge alarm does not make audible noise in pilot house as required at operating station.(46CFR143.230(a)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2021
Resolved 17 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 November 2021
Resolved
Provide proper configuration of ring buoys, needs at least two ring buoys, two with a floating waterlight, and one with lifeline attached.(46CFR141.360(a)(2)
46CFR141.360(c)(1-2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2021
Resolved 17 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 November 2021
Resolved
PFD on bridge needs a functioning light, replace light or battery to rectify inoperable light.(46CFR141.340(g)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2021
Resolved 17 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 November 2021
Resolved
A PFD is required in each accommodation space, place a PFD in each accomodation space. (46CFR141.340(d))
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2021
Resolved 17 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 November 2021
Resolved
Ring Life buoys must have proper retro-reflective tape in good condition, replace all retro reflective tape on ring life buoys with type II retro-reflective tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2021
Resolved 17 December 2021