MAURY USCG vessel records Sign in
← All vessels

CHEMTRANS STAR

CHEMTRANS STAR is a 2000 tank ship. The Coast Guard has recorded 36 inspections since 2001, most recently in April 2018, along with 11 deficiencies and 7 operational controls.

Records from 2001 to 2018. Most recent: inspection, 27 April 2018.

Built
2000
Last inspected
27 April 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9185516 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-18639

Inspections, by type

…with no type recorded14
Years with a record 15 calendar years (2001–2018)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it63331 - Dead Weight, Ton
76591 - Displacement, Ton
37033 - Convention (Subpart B), Gross Ton
18448 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 36

27 April 2018 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6397864
21 April 2017 COC-TVE Renew · COE-Dockside · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6129497
21 June 2014 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4887662
14 June 2012 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4343498
1 February 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3937021
7 September 2010 COE-Dockside
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3844632
22 March 2010 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3690796
1 April 2009 COE-Dockside
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3444964
18 February 2009 COE-Dockside
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3420052
29 January 2009 ISPS II Exam · COC-TVE Annual · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3401493
8 September 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3320633
22 July 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3275450
2 February 2008 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3140774
18 January 2007 Deficiency Check · COC-TVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2856571
27 September 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2788376
28 July 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2728234
26 July 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2725189
23 January 2006 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2572167
6 January 2006 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2562130
6 January 2006 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2562162
9 August 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2456954
24 March 2005 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2318729
16 February 2005 COC-TVE Annual · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2293980
5 January 2005 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2269333
8 October 2004 Random ISPS/MTSA/PSC
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2216827
22 June 2004 ISPS II Exam · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2106612
5 March 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2019191
23 January 2004 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1991713
28 February 2003 Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1745726
25 May 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1621913
6 May 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1614779
13 January 2002 Certificate of Compliance · Tank Vessel Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1477510
18 June 2001 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 291121
26 March 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 288316
17 January 2001 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 286121
17 January 2001 Tank Vessel Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1056923

Deficiency record · 11

Deck/Cargo › Inert Gas System › IGS Blower
Issued 27 April 2018 Resolved
The inert gas system shall be designed, constructed and tested in accordance with the Fire Safety Systems Code. Special consideration shall be given to the design and location of scrubber and blowers with relevant piping and fittings in order to preven flue gas leakages into enclosed spaces. PSCO detected flue gas leaking into the IG space. SOLAS 74 (2004 Cons) II-2/4.5.5.3.2 FSS Code 15.2.3.1.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2018
Resolution: Received satisfactory class report from ABS confirming repairs and functional IGS.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 27 April 2018 Resolved
The inert gas system shall be capable of inerting, purging and gas-freeing empty tanks and maintaining the atmosphere in cargo tanks with the required oxygen content. The oxygen analyzer was unable to be calibrated and flue gas was not able to go below 5%. SOLAS 74 (2004 Cons) II-2/4.5.5.3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2018
Resolution: Received satisfactory class report from ABS confirming repairs and functional IGS.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 27 April 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Marine sanitation device was found to have soft patches and pinhole leaks. SOLAS 74 (2004 Cons) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 May 2018
Resolution: Received class report stating: MSD was opened, internally and externally cleaned and the pinhole sealed with epoxy. Permanent repairs to be differed until the next dry-docking survey, due 30 January 2019.
Lifesaving › Launching Appliances › Davit
Issued 27 April 2018 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO witnessed the starboard lifeboat davit arms were misaligned by 10 inches. SOLAS 74 (2004) III/20.1
Action required: 10 - Deficiency Rectified
Resolved 27 April 2018
Resolution: PSCO witnessed the crew fix the alignment of the davit arms.
Fire Fighting › Ventilation Systems › Fans
Issued 21 April 2017 Resolved
Cargo pump rooms shall be mechanically ventilated and discharges from the exhasut fans shall be led to a safe place on deck. While tje fan was operating for the cargo pump room, a bolt sheered off causing the fan to stop. Bolt was replaced and fan continued to operate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: Corrected on the spot.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 2 February 2008 Resolved
Vessel's hospital accommodation space was been used as crew accommodation. Port State Control Officers immediately notified master of vessel to remove crew from hospital space. The deficiency was rectified on the spot. Cite: ILO-147
Action required: 705 - Other - as specified
Due 2 February 2008
Resolved 2 February 2008
Resolution: Deficiency was rectified on the spot.
Navigation › Collision/Grounding Avoidance › Radar
Issued 26 July 2006 Resolved
Primary and Secondary radar are inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2006
Resolution: Received technicians report attesting to proper repairs of both radars.
Lifesaving
Issued 17 January 2001 Resolved
Create and utilize a lifesaving equipment maintenance manual in accordance with SOLAS 74 amended Chapter III, Reg. 20 and 36.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Lifesaving
Issued 17 January 2001 Resolved
Permanently secure the walkway/wood grating located around the steering gear.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Lifesaving
Issued 17 January 2001 Resolved
Prior to cargo operations provide adequate number of EEBDs for the cargo pumproom.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Electrical
Issued 17 January 2001 Resolved
In lieu of plastic wire run hangers, properly install metallic hangers.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.