MAURY USCG vessel records Sign in
← All vessels

NAVIOS APOLLON

NAVIOS APOLLON is a 2000 freight ship. The Coast Guard has recorded 13 inspections since 2003, most recently in January 2017, along with 3 deficiencies and 2 operational controls, 1 with no removal date recorded.

Records from 2003 to 2017. Most recent: inspection, 23 January 2017.

Built
2000
Last inspected
23 January 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9211145 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-18640

Inspections, by type

…with no type recorded4
Years with a record 7 calendar years (2003–2017)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it60531 - Displacement, Ton
52073 - Dead Weight, Ton
29499 - Convention (Subpart B), Gross Ton
17889 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

23 January 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6075343
3 January 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6064927
20 January 2012 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4228387
23 December 2011 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4207225
19 December 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4207227
5 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3885808
5 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3887328
5 November 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3888718
25 October 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3877045
11 January 2008 MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3124401
18 March 2005 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2313480
17 February 2005 ISPS II Exam · Ballast Water Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2294230
21 September 2003 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1909354

Deficiency record · 3

Electrical › Electrical Distribution System (emergency) › Wiring
Issued 3 January 2017 Resolved
0954-All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Electrical wires for the anti-piracy alarm in the emergency generator room were exposed. 74 SOLAS(2004)II-1/45.1.3 (40a,c)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 January 2017
Resolved 23 January 2017
Resolution: Received report from LR attesting to the removal of the wires pertaining to the deficiency due to the equipment being taken out of service.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 23 December 2011 Resolved
0199-Certificates-No vessel may use any equipment for transfer operations unless the vessel test and inspects the equipment. Each hose or pipe used for transfer must not burst, bulge leak under static liquid pressure test at least 1.5 times the maximum allowable working pressure. Vessel conducted bunker line test using air as medium.33CFR156.170
Action required: 703 - Prior to bunkering operations
Due 23 December 2011
Resolved 18 January 2012
Resolution: Received documentation for the vessel''s Captain satisfying the requirement.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 5 November 2010 Resolved
The vessel experienced a Power Irregularity due to a Flow Alarm Sensor for lubricator of cylinder liner no.2, at MM 41, Lower Mississippi River above Head of Passes.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 November 2010
Resolved 6 November 2010
Resolution: Received, reviewed and accepted class report from Lloyd''s stating that the sensor for cylinder no.2 was replaced, tested and found satisfactory.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.