MAURY USCG vessel records
← All vessels

GRAND LUAU

GRAND LUAU is a 1977 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in May 2026, along with 17 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 22 May 2026.

Built
1977
Last inspected
22 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI2789
186644
Flag
UNITED STATES
Maury page id
psix-186644

Documentation record

Registered dimensions (L × B × D)47.0 ft × 14.0 ft × 4.3 ft
Registered tonnagegross 38 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLACROSSE, WI, UNITED STATES · built 1977
Hull materialSteel
PropulsionGasoline Inboard
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 21 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Simplified, Gross Ton
30 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 21

22 May 2026 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8378566
6 May 2026 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8367784
19 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8138952
13 May 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7911195
21 December 2023 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7841391
26 September 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7798485
9 June 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7710563
17 May 2023 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7690266
28 April 2022 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7425965
6 October 2021 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7327919
17 May 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7199960
18 July 2019 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6755445
5 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6705244
29 August 2018 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6526141
31 January 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6347093
9 July 2017 Type not recorded
No type recorded · Coast Guard Station Chicago · USCG Great Lakes District (CGD-GL) · Activity 6203753
23 May 2017 Construction Oversight · Deficiency Check · COI Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6153490
29 March 2017 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6116529
11 October 2016 Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6020218
27 June 2016 Plan Review "T" Boat
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5968660
6 June 2016 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5898982

Deficiency record · 17

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2026 Resolved
The lights on a vessel of 12 meters or more in length but less than 50 meters must be visible for 2-miles. The sidelights are obstructed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2026
Resolved 22 May 2026
Resolution: the tiki grass causing the obstruction has been cut back.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2025 Resolved
Remove blower and dead end wires at bulkhead in the machinery space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 20 May 2025
Resolution: Blower and wiring were removed.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 19 May 2025 Resolved
Clean Leaves and Debris and clean engine backfire flame arresters.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 20 May 2025
Resolution: engineroom was cleaned as well as both main engine flame arresters.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 May 2024 Resolved
Pre engineered fixed gas fire extinguishing system must be of the manual actuation and automatic operation. The fire boy pull station cable is not installed properly.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2024
Resolution: Owner provided pictures of manual pull attachment, inspection tag, and invoice from qualified service technician.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 13 May 2024 Resolved
Guards must be installed in hazardous places. No guards are installed on the Main engine pulley system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 18 July 2024
Resolution: Guards installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2024 Resolved
Each life ring on a vessel must be approved IAW subchapter Q. the line on the STBD AFT corner need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 19 July 2024
Resolution: rings were replaced
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 17 May 2023 Resolved
Master must have a valid FCC Marine Radio Operator permit IAW 47 CFR 80.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 26 September 2023
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 17 May 2023 Resolved
Company must create a program to track and document crew training prior to the operating season and at least once every 3 months during season for all vessels.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 9 June 2023
Resolution: Company created system to track and audit training of crew
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2022 Resolved
Replace both life ring lines due to deterioation and FWD upper deck float light line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2023
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 28 April 2022 Resolved
Install missing/loose hardware on upper deck stancions on bow
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2023
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 April 2022 Resolved
Download or print coast pilot, light list, and e-charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2023
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 17 May 2021 Resolved
No emergency broadcast placard posted. Post emergency broadcast placard to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 May 2021
Resolution: Crew posted emergency broadcast placard.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 May 2021 Resolved
No current USCG Light List on board. Provide current USCG Light List on board.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 May 2021
Resolution: Crew downloaded Light List to digital library.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 5 June 2019 Resolved
Company of vessel has employee in a deckhand position who is not proven in an estabilished program for chemical testing of dangerous drugs on random basis nor can prove pre-employment chemical testing. Remove employee from company vessel as crewmember or prove chemical testing to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2019
Resolved 18 July 2019
Resolution: Vessel provided updated crew list that showed Courtney enrolled in chemical testing
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 June 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2019
Resolved 18 July 2019
Resolution: Had FCC station license on board
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 January 2018 Resolved
After two seperate accidents, both resulted in broken arms, Slide installation must meet ASTM F2376 or equimalent standard. 46 CFR 176.830(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 18 July 2019
Resolution: Installed slide that met ASTM standards and MSU Chicago requirements
Electrical › Electrical Distribution System (service) › Conductor
Issued 1 June 2017 Resolved
Renew all wire to approved plans 12vdc system. 12 awg called out on plan vice 16 and 14 awg that was used.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 26 June 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.