Records from 1985 to 2016. Most recent: inspection, 8 September 2016.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
8 September 2016
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5995553
28 April 2005
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2344979
7 April 2003
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1777689
16 October 2002
Examination of Repairs
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1690520
23 August 2002
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1665458
5 September 2001
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1379562
26 October 2000
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1430928
23 August 1999
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1365341
15 December 1998
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 808635
14 January 1998
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1108762
4 November 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 781953
20 October 1997
Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 779313
2 February 1996
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 871770
19 January 1996
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1185734
3 January 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1407643
18 November 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1174980
2 November 1994
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1179250
6 November 1993
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 846485
12 October 1993
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 831438
17 July 1992
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1254804
10 February 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 944916
9 September 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 934460
18 January 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 903681
18 December 1990
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 906233
18 October 1990
COI Inspection · Drydock Extension
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1219899
13 December 1989
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1221395
23 November 1988
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 898808
3 November 1987
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1022432
28 May 1987
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1002136
18 November 1986
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1325783
1 November 1985
Credit Drydock
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1001520
2 October 1985
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1296780
Engineering
Issued 28 February 2003
Resolved
By Feb 3, 2003, install visible and audible bilge alarm at helm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2016
Resolved 8 September 2016
Construction/Loadline
Issued 24 February 2003
Resolved
Make internal hull available for inspection (all compartments) outboard of centerline battery well .
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2016
Resolved 8 September 2016
Engineering
Issued 24 February 2003
Resolved
Install visible indicator that shows when auto bilge pump is on at helm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2016
Resolved 8 September 2016
Documentation
Issued 20 October 1997
Resolved
RENEW CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Fire Fighting
Issued 20 October 1997
Resolved
PROVIDE 1 B-II PORTABLE FIRE EXTINGUISHER PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Engineering
Issued 9 September 1991
Resolved
INSTALL PROTECTIVE SCREENS AROUND PROPULSION MOTOR ARMATURE OPENINGS.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Fire Fighting
Issued 18 October 1990
Resolved
PROVIDE 2 MARINE TYPE FIRE EXTINGUISHER BRACKETS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Fire Fighting
Issued 18 October 1990
Resolved
PROVIDE 1 ADDITIONAL B-II FIRE EXTINGUISHER PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Accommodation/Occupational Safety
Issued 18 October 1990
Resolved
FUMIGATE VESSEL FOR ANTS, ROACHES AND SPIDERS, ETC. PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Deck/Cargo
Issued 18 October 1990
Resolved
INSTALL JUNCTION BOXES FOR BILGE PUMP AND BLOWER WIRE SPLICES AND USE CRIMPCONNECTORS ONLY PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Navigation
Issued 18 October 1990
Resolved
INSTALL NAVIGATION LIGHTS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Electrical
Issued 18 October 1990
Resolved
INSTALL DECK LIGHTING PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Lifesaving
Issued 18 October 1990
Resolved
PROVIDE RINGBUOY WATERLIGHT ATTACHED WITH 3' LINE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Navigation
Issued 18 October 1990
Resolved
MAKE CONTROL CONSOLE DRIP-PROOF PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Lifesaving
Issued 18 October 1990
Resolved
PROVIDE 6 RED AND 6 ORANGE DISTRESS FLARES IN A WATERTIGHT BOX PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Documentation
Issued 18 October 1990
Resolved
POST SUITABLE EMERGENCY INSTRUCTION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Construction/Loadline
Issued 18 October 1990
Resolved
DRYDOCK VESSEL NO LATER THAN 01DEC90, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Electrical
Issued 18 October 1990
Resolved
PROVIDE WIRING DIAGRAM FOR MOTOR CONTROLLERS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Engineering
Issued 18 October 1990
Resolved
TIGHTEN STBD MOTOR ELECTRICAL CONNECTIONS PRIOR TO CARRYIN PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Electrical
Issued 18 October 1990
Resolved
REPAIR BATTERY COMPARTMENT BLOWER PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Electrical
Issued 18 October 1990
Resolved
INSTALL HOSE, BLOWER TO BATTERY COMPARTMENT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Navigation
Issued 18 October 1990
Resolved
OVERHAUL STBD RUDDER LINKAGE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Navigation
Issued 18 October 1990
Resolved
RE-FIBERGLASS STBD RUDDER POST TO HULL PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Lifesaving
Issued 18 November 1986
Resolved
ATTACH 31 SQUARE INCHES OF REFLECTIVE TAPE TO THE FRONT AND TO BACK OF ALL PFD'S.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986