Records in 2025. Most recent: inspection, 20 September 2025.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 July 2025
Resolved
Per MODU safety Certificate (1989), each unit shall carry on each side of the unit, one or more lifeboats complying with the requirements of SOLAS III. Starboard lifeboat did not start.
MODU Code (1989) 10.2.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 July 2025
Resolution: Witnessed operational test of the starboard lifeboat. All sat
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 July 2025
Resolved
An automatic fire detection and alarm system should be provided and comply with II-2. The fire detection panel was in fault and heat detector was not working.
MODU Code (1989) 9.7.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 July 2025
Resolution: Witnessed operational test of the fire detection panel and heat detector above the #3 generator. All sat
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 July 2025
Resolved
The machinery and electrical requirements container in Chapter 4 to 8 provide and acceptable degree of protection for person from fire, electrical shock or other physical injuries. Emergency switchboard room had a high concentration of CO observed by Class and [name withheld] (1989) 4.1.1
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2025
Resolution: The door to the emergency switchboard was not properly seated and CO from testing the lifeboat leaked into the space. PSCO walked the space with a 4 gas and verified no CO accumulation/leak.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 11 July 2025
Resolved
BWMS shall monitor & store a minimum number of parameters for detailed evaluation. In addition, all systems indications and alerts shall be stored and available for inspection. Ballast water record book did not match the recorded history on the Ballast Water System.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2025
Resolved 25 July 2025
Resolution: Record book was updated to reflect ballast operation.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 11 July 2025
Resolved
The Master, Owner, Operator, or Agent must submit a Ballast Water Report to the National Ballast Information Clearinghouse. A ballast water report was not submitted in the required time.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 11 July 2025