MAURY USCG vessel records
← All vessels

NEOLINER ORIGIN

NEOLINER ORIGIN is a freight ship. The Coast Guard has recorded 3 inspections in 2025, along with 13 deficiencies and 1 operational control.

Records in 2025. Most recent: inspection, 11 December 2025.

Built
Not recorded
Last inspected
11 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1021829
1872495
Flag
FRANCE
Maury page id
psix-1872495

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 1 calendar year (2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it13032 - Convention (Subpart B), Gross Ton
6639 - Dead Weight, Metric Ton
12019 - Displacement, Metric Ton
3909 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

11 December 2025 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8282272
30 October 2025 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8260895
30 October 2025 PSC A · Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8260948

Deficiency record · 13

11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 30 October 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed lifeboat, rescue boat and port side liferafts not ready for use. 74 SOLAS (24) III 20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2025
Resolution: Received RO report attesting to proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2025 Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500l and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCO observed emergency generator remote valve inoperable. 74SOLAS(24) II-2/4.2.2.3.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2025
Resolution: Received class report attesting to proper operation.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 30 October 2025 Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the Company. The technical and/or operational nature of the deficiencies noted in deficiencies 01 & 02 above provide objective evidence of a serious failure of the implementation of the ISM code. An internal audit report must be submitted to the Coast Guard and deemed satisfactory prior to clearance of this deficiency. 74SOLAS(24) IX/3.1 ISM Code 10.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2025
Resolution: Class survey attests to corrected log book.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 30 October 2025 Resolved
Inspection of the life-saving appliances, including lifeboat equipment, shall be carried out monthly using the checklist required by regulation 36.1 to ensure that they are complete and in good order. A report of the inspection shall be entered in the log-book. Vessel had no record of inspection of rescue boat life-saving appliances. 74SOLAS(24) III/20.7.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Class report attests to LSA monthly inspections to be carried out and logged.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 October 2025 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. However, hold-back arrangements fitted with remote release devices of the fail-safe type may be utilized. PSCO identified holdback on ships laundry space self-closing door. 74SOLAS(24) II-2/9.4.2.2
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Class report states laundry room door holdback to be replaced.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 30 October 2025 Resolved
General arrangement plans shall be permanently exhibited for the guidance of ship's officers, showing clearly for each deck the control stations, the various fire sections. PSCO observed multiple mis-labeled fire doors compared to vessel's fire control plan. 74SOLAS(24) II-2/15.2.4.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Doors and LSA equipment labeled as per fire control plan.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 October 2025 Resolved
If a hydrostatic release unit is used in the float-free arrangements, it shall if disposable, in lieu of the requirement in paragraph 4.1.6.3.6 be marked with a means of determining its date of expiry. PSCO identified port and starboard life ring hydrostatic releases not marked with date of expiry. 74SOLAS(24) III/34 LSA 4.1.6.3.8
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Dates verified by class surveyor.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 30 October 2025 Resolved
Each completed page or group of electronic entries of the Garbage Record Book shall be signed by the master of the ship. PSCO identified no signatures of on page 6 of Garbage Record Book. MARPOL V/10.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2025
Resolution: Class survey attests to corrected log book.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 October 2025 Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and liferaft embarkation deck. For this purpose, the following functional requirements shall be met additional aids for escape shall be provided as necessary to ensure accessibility, clear marking, and adequate design for emergency situations. PSCO identified that emergency exit in Bosn Stores not marked for emergency exit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Door marked with emergency exit per surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 October 2025 Resolved
Bilge wells in periodically unattended machinery spaces shall be located and monitored in such a way that the accumulation of liquids is detected at normal angles of trim and heel, and shall be large enough to accommodate easily the normal drainage during the unattended period. PSCO observed the port side bilge high level alarm inoperable. 74SOLAS(24) II-1/48.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Bilge alarm repaired to surveyor satisfaction.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 October 2025 Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. PSCO observed A-class boundary door "Crew corridor 558" not self-closing. 74SOLAS(24) II-2/9.4.2.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2025
Resolution: Door repaired to surveyor satisfaction.
14 - Pollution Prevention › 148 - Ballast Water › Ballast water logs/records
Issued 30 October 2025 Resolved
Include the master, owner, operator, agent, person in charge, or responsible officer's printed name, title, and signature attesting to the accuracy of the information provided and that the activities were in accordance with the ballast water management plan. PSCO identfied no sigantures in record book. 33CFR151.2070(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2025
Resolution: Class survey attests to corrected log book.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 30 October 2025 Resolved
The transfer procedures required by § 155.720 must contain, either in the order listed or by use of a cross-reference index page. PSCO identified that vessel bunkering checklist did not identify topping off procedures & emergency shutdown procedures. 33CFR155.750
Action required: 10 - Deficiency Rectified
Resolved 30 October 2025

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.