MAURY USCG vessel records Sign in
← All vessels

MSC DARWIN VI

MSC DARWIN VI is a 1999 freight ship. The Coast Guard has recorded 51 inspections since 2000, most recently in January 2026, along with 25 deficiencies and 10 operational controls.

Records from 2000 to 2026. Most recent: inspection, 31 January 2026.

Built
1999
Last inspected
31 January 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9200689 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-188

Inspections, by type

…with no type recorded18
Years with a record 16 calendar years (2000–2026)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it93049 - Displacement, Metric Ton
36993 - Convention (Subpart B), Net Ton
66278 - Convention (Subpart B), Gross Ton
68788 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 51

31 January 2026 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8304364
9 June 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8155598
4 June 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8151893
22 May 2025 PSC A · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8139108
20 May 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8139568
27 February 2024 Appeal
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7870902
12 July 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7740292
11 July 2023 In-Service Inspection · Deficiency Check · Appeal · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7733535
9 January 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6334594
5 January 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6332917
20 November 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6309474
15 November 2017 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6307776
8 November 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6302962
28 July 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6223624
1 June 2017 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6159890
30 May 2017 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6162217
26 May 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6156377
5 April 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6118153
19 December 2015 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5780360
9 November 2015 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5760593
9 November 2015 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5762970
5 November 2015 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5758399
21 September 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4151203
5 February 2010 ISPS III Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3676087
3 January 2010 Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3657499
28 August 2006 ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2762612
10 May 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2645866
10 May 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2645871
4 May 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2640836
24 March 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2609005
13 January 2006 PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2566502
10 December 2005 STCW 95 Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2549183
10 December 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2553833
9 December 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2549007
27 September 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2502555
7 July 2005 ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2418613
1 July 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2410465
4 June 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2379100
22 April 2005 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2340829
24 December 2004 PII Safety Exam · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2264380
19 August 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2171180
13 July 2004 Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2131540
7 July 2004 ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2125267
3 January 2004 Type not recorded
No type recorded · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 1974141
23 October 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1934156
13 August 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1875560
9 July 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1841405
2 May 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1785296
3 May 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1612531
9 March 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 288114
7 January 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 273476

Deficiency record · 25

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 22 May 2025 Resolved
SHIPS CONSTRUCTED ON OR AFTER 01 OCTOBER 1994, THE SOURCE OF STORED ENERGY SHALL BE PROTECTED TO PRECLUDE CRITICAL DEPLETION BY THE AUTOMATIC STARTING SYSTEM, UNLESS A SECOND INDEPENDENT MEANS OF STARTING IS PROVIDED FOR AN ADDITIONAL THREE STARTS WITHIN 30 MINUTES UNLESS MANUAL STARTS CAN BE DEMONSTRATED TO BE EFFECTIVE. PSCO OBSERVED ONE SOURCE OF ENERGY STARTING THE EMERGENCY GENERATOR AND CREW WAS UNABLE TO FIND A SEPARATE SECOND SOURCE OF ENERGY. 74SOLAS(04)II-1/44.2.1
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 June 2025
Resolution: Received class report identifying second source of energy for the emergency generator.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2025 Resolved
NO MORE THAN 208 LITERS (55 GALLONS) OF COMBUSTIBLE LIQUIDS MAY BE STOWED IN ANY MACHINERY SPACE. PSCO OBSERVED MULTIPLE 55 GALLON DRUMS OF LUBE OIL STOWED IN THE ENGINE ROOM.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 June 2025
Resolution: Reviewed class report and accepted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2025 Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. PSCO OBSERVED OPEN ELECTRICAL CONTROLLER IN THE ENGINE ROOM. 74SOLAS(04)II-1/45.1.3
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 June 2025
Resolution: Reviewed class report attesting to correction.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 July 2023 Resolved
The machinery, boilers, and other pressure vessels… and fittings shall be of design and construction adequate for the service for which they are intended and shall be so installed… to reduce to a minimum any danger to persons on board. Oil-fired boiler sight glass was broken, which introduced an open flame into the atmosphere of the engine room. 74SOLAS(01) II-1/26.1
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 July 2023
Resolution: received photograph and attestation from Flag surveyor of sight glass being replaced.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 July 2023 Resolved
The arrangements for the storage, distribution, and utilization of the oil fuel shall be as such to ensure the safety of the ship and persons on board. PSCO witnessed excessive oil accumulation throughout the entire engine room. Multiple pipes and critical engineering equipment and machinery were saturated in oil. Oil purifier catch basin found filled with oil. Excessive oil soaked rags were found on main engine, generators, and oil purifiers to slow active leaks. In addition, PSCO observed excessive oily water in the vessel's bilge, increasing the risk of fire growth and potential & creating a hazardous and unsafe condition for the crew. 74SOLAS(01) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 19 July 2023
Resolution: PSC team observed appropriate rectifications to listed deficiencies including oily-rags removed, catch basins removed, oil soaked lagging replaced, excessive oily water in bilge removed. Class report attached to documents.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 11 July 2023 Resolved
Exposed metal parts of electrical machines or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed. 440v reefer distribution panels were found with no bonding cables or wasted with no connection to earthed joint. In addition, multiple cargo deck lights were found extinguished or not maintaining intrinsically safe condition. 74SOLAS(01) II-1/45.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 19 July 2023
Resolution: Team also observed rectifications to electrical bonding cables for deck lighting and 440v distribution panels. Class report attached.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 11 July 2023 Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed steady, continuous leak from steam piping in two locations in aft starboard engine room. 74SOLAS(01) II-1/33.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2023
Resolution: Water leak from steam pipe was adequately repaired. Class report in documents.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 11 July 2023 Resolved
Satisfactory means (in the form of guard rails, lifelines, gangways, etc.) shall be provided for the protection of the crew in getting to and from their quarters, machinery space and all other parts used in the necessary work of the ship. Catwalks in cargo area were found wasted and detached from deck and lifelines were not in place or rendered ineffective due to rust. ILLC ANN I/25.4
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 11 July 2023 Resolved
Arrangements shall be provided to enable the pilot to embark and disembark safely on either side of the ship. Starboard side accommodation ladder stantion securing brackets were found severely rusted and the hand rails were not securely fastened. 74SOLAS(20) V/23.3.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 May 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 July 2023 Resolved
The storage, distribution, and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons onboard. over 15 waste recepticals containing oily rags were stored throughout the engine room, some of which were leaking oil onto the deck. 74SOLAS(01) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 July 2023
Resolution: received photograph and attestation from Flag surveyor of oily waste removal from engine room.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 9 January 2018 Resolved
All ships of 500 gross tonnage and upwardsshall have a gyro-compass heading repeater, or other means, to supply heading information visually at the emergency steering postition if provided. The gyro-compass repeater in the emergency steering position has a malfunctioning digital display. Solas 74 (2014 Cons.) V/19.2.5.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 9 January 2018
Engineering › Steering Gear System › Pump
Issued 9 January 2018 Resolved
Hydraulic power-operated steering gear shall be provided with a low-level alarm for each hydraulic fluid reservoir to give the earliest practical indication of hydraulic fluid leakage. The low-level hydraulic fluid reservoir alarm was inoperable during testing on the No. 1 steering gear pump. Solas 74 (2004 Cons.) II-1/29.12.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 9 January 2018
Resolution: Rectified on-scene.
Engineering › Diesel Engine (propulsion-electric) › Pump, Positive Displacement
Issued 16 November 2017 Resolved
The following functional requirements shall be met (1) means shall be provided to control leakes aof flammable liquids. On the #2 diesel generator, evidence was noted of an excessive leak of diesel fuel, whcih had sprayed in the vicinity of the engine as well as onto a lower deck. 74 SOLAS (01) II-2/4.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 January 2018
Resolution: PSC HOU received DNV GL class report satisfying the requirement.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 15 November 2017 Resolved
Machinery spaces and fittings shall be of design and construction adequate for the service for which they are intended. Main engine will not start. Also, the engine control from the bridge is inoperable. 74SOLAS(04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2017
Resolution: Received class report from DNV-GL stating that the fuel pump on the #2 generator was replaced.
Electrical › Electric Generation Source (service) › Generator
Issued 3 January 2010 Resolved
UPON TESTING OF THE NO.3 GENERATOR FOUND FUEL OIL LEAKS WITH FUEL OIL PIPING ALSO FOUND THE MOTOR TO THE PRELUBE PUMP INOPERABLE. A REPORT ATTESTING TO THE PROPER OPERATION OF THE NO.3 GENERATOR IS TO BE PROVIDED TO THE SATISFACTION OF CLASS.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 February 2010
Resolved 6 February 2010
Resolution: Verfied new electric motor onboard allowing for proper operation of pre-lube oil pump for no.3 generator. No.3 gen operable by cross-connecting pre-lube pumps from other gen sets Altered deficiency to 70c (from 70a) and noted as rectified. -[name withheld]
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 3 January 2010 Resolved
AT THIS TIME RADIO ANTENNA FOR MF/HF RADIO WAS FOUND BROKEN AND THE MF/HF RADIO INOPERABLE. REPAIRS TO THE RADIO ANTENNA AND PROPER OPERATIONS OF THE MF/HF RADIO IS TO BE CONDUCTED BY APPROVED REPAIR VENDORS OF THE MF/HF RADIO. A SATISFACTORY CLASS REPORT IS TO BE SUBMITTED TO THE USCG ATTESTING TO THE WORKING OPERATIONS OF THE RADIO AND REPAIRS TO THE ANTENNA.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2010
Resolved 5 January 2010
Resolution: Sector LA-LB received a GL class report stating that a new attenna has been assembled and mounted. Unit tested satisfactorily. Deficiency rectified. -[name withheld]
Lifesaving › Launching Appliances › Release Mechanism
Issued 3 January 2010 Resolved
UPON LOWERING STARBOARD LIFEBOAT, THE AUTOMATIC RELEASE WIRE TANGLED AND BROKE. AS IS THE STARBOARD LIFEBOAT CAN NOT BE LOWERED FROM WITH IN. THE LIFE BOAT MUST BE LOWERED WITH THE ASSISTANCE OF A CREW MEMEBER ON DECK. THE WIRE IS TO RENEWED WITH LIKE WIRE AND SATISFACTORY CLASS REPORT SUBMITTED TO THE USCG.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2010
Resolved 5 January 2010
Resolution: Sector LA-LB received a GL class report stating the the entangles remote lowering wire was cut off and a new wire was installed. Satisfactory test witnessed by GL surveyor. Deficiency rectified. -[name withheld]
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 3 January 2010 Resolved
UPON TESTING OF THE EMERGENCY GENERATOR THE AUTOMATIC STARTING OF THE GENERATOR DID NOT TAKE PLACE UPON FAILURE OF THE MAIN SORUCE OF POWER. PROOF OF PROPER OPERATIONS OF THE EMERGENCY GENERATOR IS REQUIRED. TO THE SATISFACTION OF CLASS AND USCG
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2010
Resolved 5 January 2010
Resolution: Sector LA-LB received GL report stating that problem was low voltage of 24v starting battery system. Batteries were replaced and a successful sequence test was performed. Deficiency rectified. -[name withheld]
Fire Fighting › Structural - A Class Divisions › Doors
Issued 13 January 2006 Resolved
Fire doors in and adjacent to galley (which were required to be self closing) were fitted with hold back hooks. SOLAS 2001CONS II-2/47.2
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 13 January 2006
Resolution: Hooks were removed on doors. (3 total)
Fire Fighting › Firemans Outfit › Lifeline
Issued 13 January 2006 Resolved
Tending lines for fireman's breathing apparatus were not attached by an approved means. (They were tied onto apparatus). SOLAS 2004CONS II-2/10.10.1/FSS Code III/2.1.3
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 13 January 2006
Resolution: Crew attached line to snap hooks, which could be clipped onto SCBA''''s.
Fire Fighting › Firemans Outfit › Lantern (Electric Safety Lamp)
Issued 13 January 2006 Resolved
Electrical Safety Lamps (2 of 3) for fireman's outfits were not readily available. SOLAS 2004CONS II-2/10.10.1/ FSS Code III/2.1.1.4
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 13 January 2006
Resolution: Crew added approved lanterns to bags where fireman''s outfits were stowed.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 10 December 2005 Resolved
Vessel attempted to get underway in contravention to the Safe Manning Certificate; after report to USCG by state pilot the master and the Chief officer found to be not fit for duty due to intoxication.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 15 December 2005
Resolution: After several houres of sleep Vessel''s Master and the Chief officer were found found by the USCG to be fit for duty.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 10 December 2005 Resolved
During machinery light offs/preparations to get underway, the vessel's master and chief officer were found to be intoxicated; testing by USCG foung Master's BAC was .100, the Chief officer's BAC was .084. This is above the U.S. Federal leagle limit of .04.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 10 December 2005
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 10 December 2005 Resolved
Ship's master did not sleep from 0600 Friday, Dec 9th to 1000 Sat Dec 10th; Ship's [name withheld] did not sleep from 0600 Friday Dec 9th to 0700 sat. Dec 10th. In order to comply with minimum rest period for watch keeping, ship cannot get underway until 1700 Saturday, Dec 10th.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 10 December 2005
Resolution: Ship''s master slept from 1000 to 2000. Ship''s [name withheld] slept from 0700 to 1700.
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 10 December 2005 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 10 December 2005
Resolution: Ships Master and [name withheld] waited 19 Hr. to go on watch.

Ownership record