← All vessels
MSC DARWIN VI
MSC DARWIN VI is a 1999 freight ship. The Coast Guard has recorded 51 inspections since 2000, most recently in January 2026, along with 25 deficiencies and 10 operational controls.
Records from 2000 to 2026. Most recent: inspection, 31 January 2026.
- Built
- 1999
- Last inspected
- 31 January 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 25 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9200689 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5SI4
188
Flag
LIBERIA
—
Maury page id
psix-188
Inspections, by type
…with no type recorded18
Years with a record
16 calendar years (2000–2026)
The 51 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it93049 - Displacement, Metric Ton
36993 - Convention (Subpart B), Net Ton
66278 - Convention (Subpart B), Gross Ton
68788 - Dead Weight, Metric Ton
36993 - Convention (Subpart B), Net Ton
66278 - Convention (Subpart B), Gross Ton
68788 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 51
31 January 2026
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8304364
9 June 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8155598
4 June 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8151893
22 May 2025
PSC A · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8139108
20 May 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8139568
27 February 2024
Appeal
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7870902
12 July 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7740292
11 July 2023
In-Service Inspection · Deficiency Check · Appeal · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7733535
9 January 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6334594
5 January 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6332917
20 November 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6309474
15 November 2017
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6307776
8 November 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6302962
28 July 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6223624
1 June 2017
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6159890
30 May 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6162217
26 May 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6156377
5 April 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6118153
19 December 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5780360
9 November 2015
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5760593
9 November 2015
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5762970
5 November 2015
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5758399
21 September 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4151203
5 February 2010
ISPS III Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3676087
3 January 2010
Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3657499
28 August 2006
ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2762612
10 May 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2645866
10 May 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2645871
4 May 2006
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2640836
24 March 2006
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2609005
13 January 2006
PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2566502
10 December 2005
STCW 95 Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2549183
10 December 2005
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2553833
9 December 2005
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2549007
27 September 2005
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2502555
7 July 2005
ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2418613
1 July 2005
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2410465
4 June 2005
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2379100
22 April 2005
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2340829
24 December 2004
PII Safety Exam · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2264380
19 August 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2171180
13 July 2004
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2131540
7 July 2004
ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2125267
3 January 2004
Type not recorded
No type recorded · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 1974141
23 October 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1934156
13 August 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1875560
9 July 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1841405
2 May 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1785296
3 May 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1612531
9 March 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 288114
7 January 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 273476
Deficiency record · 25
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 22 May 2025
Resolved
SHIPS CONSTRUCTED ON OR AFTER 01 OCTOBER 1994, THE SOURCE OF STORED ENERGY SHALL BE PROTECTED TO PRECLUDE CRITICAL DEPLETION BY THE AUTOMATIC STARTING SYSTEM, UNLESS A SECOND INDEPENDENT MEANS OF STARTING IS PROVIDED FOR AN ADDITIONAL THREE STARTS WITHIN 30 MINUTES UNLESS MANUAL STARTS CAN BE DEMONSTRATED TO BE EFFECTIVE. PSCO OBSERVED ONE SOURCE OF ENERGY STARTING THE EMERGENCY GENERATOR AND CREW WAS UNABLE TO FIND A SEPARATE SECOND SOURCE OF ENERGY.
74SOLAS(04)II-1/44.2.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2025
Resolved
NO MORE THAN 208 LITERS (55 GALLONS) OF COMBUSTIBLE LIQUIDS MAY BE STOWED IN ANY MACHINERY SPACE. PSCO OBSERVED MULTIPLE 55 GALLON DRUMS OF LUBE OIL STOWED IN THE ENGINE ROOM.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2025
Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. PSCO OBSERVED OPEN ELECTRICAL CONTROLLER IN THE ENGINE ROOM.
74SOLAS(04)II-1/45.1.3
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 July 2023
Resolved
The machinery, boilers, and other pressure vessels… and fittings shall be of design and construction adequate for the service for which they are intended and shall be so installed… to reduce to a minimum any danger to persons on board. Oil-fired boiler sight glass was broken, which introduced an open flame into the atmosphere of the engine room. 74SOLAS(01) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 July 2023
Resolved
The arrangements for the storage, distribution, and utilization of the oil fuel shall be as such to ensure the safety of the ship and persons on board. PSCO witnessed excessive oil accumulation throughout the entire engine room. Multiple pipes and critical engineering equipment and machinery were saturated in oil. Oil purifier catch basin found filled with oil. Excessive oil soaked rags were found on main engine, generators, and oil purifiers to slow active leaks. In addition, PSCO observed excessive oily water in the vessel's bilge, increasing the risk of fire growth and potential & creating a hazardous and unsafe condition for the crew.
74SOLAS(01) II-2/15.2
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 11 July 2023
Resolved
Exposed metal parts of electrical machines or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed. 440v reefer distribution panels were found with no bonding cables or wasted with no connection to earthed joint. In addition, multiple cargo deck lights were found extinguished or not maintaining intrinsically safe condition.
74SOLAS(01) II-1/45.1
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 11 July 2023
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed steady, continuous leak from steam piping in two locations in aft starboard engine room.
74SOLAS(01) II-1/33.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 11 July 2023
Resolved
Satisfactory means (in the form of guard rails, lifelines, gangways, etc.) shall be provided for the protection of the crew in getting to and from their quarters, machinery space and all other parts used in the necessary work of the ship. Catwalks in cargo area were found wasted and detached from deck and lifelines were not in place or rendered ineffective due to rust. ILLC ANN I/25.4
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 11 July 2023
Resolved
Arrangements shall be provided to enable the pilot to embark and disembark safely on either side of the ship. Starboard side accommodation ladder stantion securing brackets were found severely rusted and the hand rails were not securely fastened. 74SOLAS(20) V/23.3.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 July 2023
Resolved
The storage, distribution, and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons onboard. over 15 waste recepticals containing oily rags were stored throughout the engine room, some of which were leaking oil onto the deck. 74SOLAS(01) II-2/15.2
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 9 January 2018
Resolved
All ships of 500 gross tonnage and upwardsshall have a gyro-compass heading repeater, or other means, to supply heading information visually at the emergency steering postition if provided. The gyro-compass repeater in the emergency steering position has a malfunctioning digital display.
Solas 74 (2014 Cons.) V/19.2.5.2
Engineering › Steering Gear System › Pump
Issued 9 January 2018
Resolved
Hydraulic power-operated steering gear shall be provided with a low-level alarm for each hydraulic fluid reservoir to give the earliest practical indication of hydraulic fluid leakage. The low-level hydraulic fluid reservoir alarm was inoperable during testing on the No. 1 steering gear pump.
Solas 74 (2004 Cons.) II-1/29.12.2
Engineering › Diesel Engine (propulsion-electric) › Pump, Positive Displacement
Issued 16 November 2017
Resolved
The following functional requirements shall be met (1) means shall be provided to control leakes aof flammable liquids. On the #2 diesel generator, evidence was noted of an excessive leak of diesel fuel, whcih had sprayed in the vicinity of the engine as well as onto a lower deck. 74 SOLAS (01) II-2/4.1.1
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 15 November 2017
Resolved
Machinery spaces and fittings shall be of design and construction adequate for the service for which they are intended. Main engine will not start. Also, the engine control from the bridge is inoperable. 74SOLAS(04) II-1/26.1
Electrical › Electric Generation Source (service) › Generator
Issued 3 January 2010
Resolved
UPON TESTING OF THE NO.3 GENERATOR FOUND FUEL OIL LEAKS WITH FUEL OIL PIPING ALSO FOUND THE MOTOR TO THE PRELUBE PUMP INOPERABLE. A REPORT ATTESTING TO THE PROPER OPERATION OF THE NO.3 GENERATOR IS TO BE PROVIDED TO THE SATISFACTION OF CLASS.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 3 January 2010
Resolved
AT THIS TIME RADIO ANTENNA FOR MF/HF RADIO WAS FOUND BROKEN AND THE MF/HF RADIO INOPERABLE. REPAIRS TO THE RADIO ANTENNA AND PROPER OPERATIONS OF THE MF/HF RADIO IS TO BE CONDUCTED BY APPROVED REPAIR VENDORS OF THE MF/HF RADIO. A SATISFACTORY CLASS REPORT IS TO BE SUBMITTED TO THE USCG ATTESTING TO THE WORKING OPERATIONS OF THE RADIO AND REPAIRS TO THE ANTENNA.
Lifesaving › Launching Appliances › Release Mechanism
Issued 3 January 2010
Resolved
UPON LOWERING STARBOARD LIFEBOAT, THE AUTOMATIC RELEASE WIRE TANGLED AND BROKE. AS IS THE STARBOARD LIFEBOAT CAN NOT BE LOWERED FROM WITH IN. THE LIFE BOAT MUST BE LOWERED WITH THE ASSISTANCE OF A CREW MEMEBER ON DECK. THE WIRE IS TO RENEWED WITH LIKE WIRE AND SATISFACTORY CLASS REPORT SUBMITTED TO THE USCG.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 3 January 2010
Resolved
UPON TESTING OF THE EMERGENCY GENERATOR THE AUTOMATIC STARTING OF THE GENERATOR DID NOT TAKE PLACE UPON FAILURE OF THE MAIN SORUCE OF POWER. PROOF OF PROPER OPERATIONS OF THE EMERGENCY GENERATOR IS REQUIRED. TO THE SATISFACTION OF CLASS AND USCG
Fire Fighting › Structural - A Class Divisions › Doors
Issued 13 January 2006
Resolved
Fire doors in and adjacent to galley (which were required to be self closing) were fitted with hold back hooks. SOLAS 2001CONS II-2/47.2
Fire Fighting › Firemans Outfit › Lifeline
Issued 13 January 2006
Resolved
Tending lines for fireman's breathing apparatus were not attached by an approved means. (They were tied onto apparatus). SOLAS 2004CONS II-2/10.10.1/FSS Code III/2.1.3
Fire Fighting › Firemans Outfit › Lantern (Electric Safety Lamp)
Issued 13 January 2006
Resolved
Electrical Safety Lamps (2 of 3) for fireman's outfits were not readily available. SOLAS 2004CONS II-2/10.10.1/ FSS Code III/2.1.1.4
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 10 December 2005
Resolved
Vessel attempted to get underway in contravention to the Safe Manning Certificate; after report to USCG by state pilot the master and the Chief officer found to be not fit for duty due to intoxication.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 10 December 2005
Resolved
During machinery light offs/preparations to get underway, the vessel's master and chief officer were found to be intoxicated; testing by USCG foung Master's BAC was .100, the Chief officer's BAC was .084. This is above the U.S. Federal leagle limit of .04.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 10 December 2005
Resolved
Ship's master did not sleep from 0600 Friday, Dec 9th to 1000 Sat Dec 10th; Ship's [name withheld] did not sleep from 0600 Friday Dec 9th to 0700 sat. Dec 10th. In order to comply with minimum rest period for watch keeping, ship cannot get underway until 1700 Saturday, Dec 10th.
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 10 December 2005
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.