Records in 2004. Most recent: inspection, 23 March 2004.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Engineering
Issued 23 March 2004
Resolved
23 Mar 04: Alarm panel in engine control room is missing. Prior to departing US, provide certificate issuing authority report to Coast Guard attesting to the proper operation of all engine room alarms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2004
Resolution: Class recommendation issued to demonstrate proper operation of engine room automation system including all alarms. Engine Room watch to be maintained until definitive repairs are carried out.
Pollution Prevention/Response › Prevention Equipment
Issued 23 March 2004
Resolved
23 Mar 04: Oily Water Separator audible and visual alarms do not work. Prior to departing US, provide certificate issuing authority report to Coast Guard attesting to the proper operation of audible and visual alarms of the oily water separator. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2004
Resolution: Class confirmed operation of local visual alarm and closing of discharge valve at 15 ppm. Class recommendation issued requiring definitive repairs of alarm system be completed with all slps retained onboard and discharged to shore reception facility.
Pollution Prevention/Response › Prevention Equipment
Issued 23 March 2004
Resolved
23 Mar 04: Bilge audible and visual alarms do not work. Prior to departing US, provide certificate issuing authority report to Coast Guard attesting to the proper operation of bilge audible and visual alarms. LEGACY COMPONENT DESC: Bilge Monitor
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2004
Resolution: Class recommendation issued to demonstrate proper operation of engine room automation system including all alarms. Engine Room watch to be maintained until definitive repairs are carried out.
Navigation › Emergency Steering
Issued 23 March 2004
Resolved
23 Mar 04: Unable to test low hydraulic oil alarms for steering pumps. Prior to departing US, provide certificate issuing authority report to Coast Guard attesting to the proper operation of low hydraulic oil alarms for the steering pumps.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2004
Resolution: Received faxed report from class confirming the proper operation audible and visual alarms for steering gear low oil level, loss of power, control failure, and loss of phase for both steering gear pumps on bridge.
Operations/Management › Equipment Service/Testing
Issued 23 March 2004
Resolved
23 Mar 04: No air compressor servicing report on-board. Prior to departing US, provide 3rd party servicing report to Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2004
Resolution: Received faxed report verifying that air compressor has been serviced by an expert.
Communications › Radio Communications
Issued 23 March 2004
Resolved
23 Mar 04: Emergency batteries for GMDSS are not properly secured. Provide letter from master stating that batteries are properly secured no later than 7 April 2004. LEGACY COMPONENT DESC: Emergency Source of Power
Due 7 April 2004
Resolved 24 March 2004
Resolution: Received report from class confirming that the emergency batteries for the GMDSS are properly secured.
Deck/Cargo
Issued 23 March 2004
Resolved
23 Mar 04: Vessel only had draegar tubes for propane and butane cargos. Prior to departing US, fax receipt attesting to the purchase of draegar tubes for all cargos authorized by the Certificate of Fitness.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2004
Resolution: Received faxed copy of receipt verifying that draegar tubes for all cargos authorized by the COF have been purchased and are on-board.