← All vessels
MONARCA I
MONARCA I is a 2005 tank ship. The Coast Guard has recorded 1 inspection in 2025, along with 13 deficiencies and 1 operational control.
Records in 2025. Most recent: operational control imposed, 15 November 2025.
- Built
- 2005
- Last inspected
- 15 November 2025
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Inspection record
Last inspected
15 November 2025
Deficiencies
13 recorded · 0
without a recorded resolution
Operational controls
None recorded without a removal date
Years with a record
1 calendar year (2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Identity
9460409
3E8720
1883029
Flag
PANAMA
Maury page id
psix-1883029
Documentation record
Tonnage as PSIX records it2951 - Convention (Subpart B), Gross Ton
4900 - Dead Weight, Ton
1556 - Convention (Subpart B), Net Ton
4900 - Dead Weight, Ton
1556 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 1
15 November 2025
PSC A · Deficiency Check · COC-TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8261948
Deficiency record · 13
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 15 November 2025
Resolved
The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. The safety management system should provide for specific measures should include the regular testing of stand-by arrangements and equipment of technical systems that are not in continuous use. The vessel provided completed weekly checklist for the emergency fire pump, but they do not document any actual testing of the pump. The emergency fire pump was inoperable. Recommend an external audit.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 November 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The emergency fire pump was inoperable.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 November 2025
Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-0" class divisions and be protected by self-closing doors at all levels. The deck level stairway door was missing completely and 02 additional stairway doors were held open using hold back deices in the main stairway.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 15 November 2025
Resolved
Emergency escape breathing devices shall comply with the Fire Safety Systems Code. PSCO found 02 EEBDs in the engine room that were depleted.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 15 November 2025
Resolved
Tankers shall be equipped with at least one portable instrument for measuring oxygen and one for measuring flammable vapour concentrations, together with a sufficient set of spares. PSCO observed only one portable instrument onboard and only one calibration gas bottle.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 November 2025
Resolved
Each cargo tank of a tankship must be equipped with an intrinsically safe high level alarm and a tank overfill alarm. PSCO observed tank overfill alarms for #1 and #2 slop tanks, #1 stbd, #3 port, and #5 port cargo tanks were inoperable.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 November 2025
Resolved
Whenever an accident occurs to a ship or a defect is discovered, either of which affects the safety of the ship or the efficiency or completeness of its life-saving appliances or other equipment, the master or owner of the ship shall report at the earliest opportunity to the Administration, the nominated surveyor or recognized organization responsible for issueing the relevant certificate, who shall cause investigations to be initiated to determine whether a survey, as required by regulations 7,8,9, or 10 is necessary. PSCO observed escape hatch in steering room overhead unable to be closed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 November 2025
Resolved
Whenever an accident occurs to a ship or a defect is discovered, either of which affects the safety of the ship or the efficiency or completeness of its life-saving appliances or other equipment, the master or owner of the ship shall report at the earliest opportunity to the Administration, the nominated surveyor or recognized organization responsible for issuing the relevant certificate, who shall cause investigations to be initiated to determine whether a survey, as required by regulations 7,8,9, or 10 is necessary. PSCO observed crew cabin porthole on stbd side of the ship missing external and internal cover.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 November 2025
Resolved
All items of lifeboat equipment, shall be secure within the lifeboat by lashings, storage in lockers or compartments, storage brackets or similar mountings arrangements or other suitable means. PSCO observed the lifeboat equipment was not secured by any arrangement.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 15 November 2025
Resolved
Fire Extinguishers shall be situated ready for use at easily visible places, which can be reached quickly and easily at any time in the event of a fire, and in such a way that their serviceability is not impaired by the weather, vibration, or external factors. PSCO observed the fire extinguishers in the battery room, lifeboat, rescue boat, and cargo pump room were not secured or mounted in brackets.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 15 November 2025
Resolved
Cylinders used for containing hazardous ships' stores that are compressed gases must be Filled, marked, and inspected in accordance with 49 CFR 173.301 through 173.308. Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place. Lockers or housings must be vented to the open air near the top and bottom for positive circulation of vapors. Cylinders must be protected from all sources of heat which may cause the cylinders to be heated to a temperature higher than 130 °F. PSCO found two cylinders of compressed gas unsecured, missing the valves protection caps, and no markings for identification.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 November 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed the main fire pump was initially inoperable, but after 30 minutes was satisfactorily tested with sufficient pressure.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 November 2025
Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-0" class divisions and be protected by self-closing doors at all levels. The deck level stairway door was missing completely and 02 additional stairway doors were held open using hold back devices in the main stairway.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National