MAURY USCG vessel records Sign in
← All vessels

NOEL C

NOEL C is a 1980 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1988, most recently in November 2025, along with 52 deficiencies and 1 casualty investigation in 2011.

Records from 1988 to 2025. Most recent: inspection, 20 November 2025.

Built
1980
Last inspected
20 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE3632
188337
Flag
UNITED STATES
367341920
Maury page id
psix-188337

Inspections, by type

…with no type recorded1
Years with a record 33 calendar years (1988–2025)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)34.5 ft × 9.9 ft × 2.7 ft
Registered tonnagegross 8 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCRILE CRISLER · NORFOLK, VA, UNITED STATES · built 1980
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portANNAPOLIS, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Regulatory (Subpart C or D), Gross Ton
7 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE3632MMSI 367341920 · active · compulsorily equipped · granted 27 February 2018, expires 8 March 2028
WTE4126MMSI not assigned · expired · compulsorily equipped · granted 12 December 1997, cancelled 19 April 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 61

20 November 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8272044
21 August 2025 Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8215561
22 January 2025 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8067425
29 August 2024 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7995873
6 February 2024 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7864288
16 November 2023 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7825694
19 October 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7811680
18 November 2022 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7596620
9 February 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7393520
18 November 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7353168
29 April 2021 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7196682
1 September 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7068797
14 August 2020 Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7033139
27 May 2019 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6695658
23 April 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6667697
3 May 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6405475
1 March 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6363681
17 August 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6244359
16 June 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5920206
11 April 2016 Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5869600
29 May 2014 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4874210
17 May 2012 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4317287
30 July 2008 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3286146
25 June 2008 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3261348
19 June 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2969397
11 July 2006 Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2762536
14 June 2006 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2681451
6 April 2006 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2627064
7 June 2005 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2310813
11 January 2005 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2274394
9 March 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2030450
1 April 2003 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2030394
9 January 2003 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1727663
12 March 2002 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1492774
12 March 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1391629
20 February 2001 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1461363
23 March 2000 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1765662
8 March 2000 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1426353
2 February 2000 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1452623
11 January 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1438957
11 March 1999 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 811038
23 March 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 787839
4 March 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1120627
19 February 1998 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 777432
7 March 1997 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1464674
19 February 1997 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1105322
14 August 1996 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1253248
5 March 1996 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1427193
7 March 1995 Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 858704
9 March 1994 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1165770
14 April 1993 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 837926
31 January 1993 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1147539
10 March 1992 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1268011
22 August 1991 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 940910
22 April 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1213495
14 March 1991 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 899978
11 April 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 921751
15 March 1990 Re-Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1292334
17 March 1989 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1041865
25 January 1989 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 892577
24 February 1988 Hull Examination · Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1032851

Deficiency record · 52

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 August 2025 Resolved
13104 - On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The visual indicator for the high level alarm was inoperable. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2025
Resolution: Received video showing proper operation of the audible alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 August 2025 Resolved
11117 - Each ring life buoy must be marked with Type II retroreflective material. The retrorefelective tape on the ring life buoy was deteriorated. 46 CFR 185.604(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2025
Resolution: Received photographic evidence the retro was replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 21 August 2025 Resolved
09110 - Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. There were dead end wires in the cabin behind the console. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2025
Resolution: Received photographic evidence the dead end wires were capped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 November 2023 Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). A submersible electric bilge pump may be used as a power bilge pump on certain vessels provided that: a positive shutoff valve is installed at the hull penetration. The subject vessel is an "old T" vessel and has individual electric submersible bilge pumps in lieu of the fixed power bilge pump required by Table 182.25-10(a). If electric submersible bilge pumps are used, the applicable requirements in "new T" must be met. The pump discharge line for the aft submersible electric bilge pump is missing a positive shutoff valve. Additionally, the flexible hose discharge line was found disconnected from the hull and any water to be discharged would have discharged back into the vessel. Fit a positive shutoff valve on the discharge line as near to the hull penetration as practicable, and connect the discharge piping so any water from the bilge line discharges overboard. 705c - due in 3 months' time (2/16/24)
Action required: 705 - Other - as specified
Due 16 February 2024
Resolved 6 February 2024
Resolution: Received email from vessel rep with objective evidence of positive shut-off valves installed at the 3 bilge discharges for the individual submersible electric bilge pumps.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 November 2023 Resolved
The owner, charterer, master, or managing operator shall instruct each crew member upon first being employed and prior to getting underway for the first time on a particular vessel, and at least once every 3 months, as to the duties that the crew member is expected to perform in an emergency, including, but not limited to, the emergency instructions listed on the mergency instruction placard required by 185.510 of this part. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Fire fighting drilsl and training shall be logged or otherwise documented for review by the Coast Guard upon request. The last recorded fire and man overboard drills/training onboard the subject vessel at the time of the annual COI inspection were from 2021. *Fire and man overboard drills were carried out during the inspection and the crew requested to log these drills, and ensure training/drills are carried out at <3 month intervals moving forward.
Action required: 10 - Deficiency Rectified
Due 16 November 2023
Resolved 16 November 2023
Resolution: Fire and man overboard drills were carried out during the inspection and the crew requested to log these drills, and ensure training/drills are carried out at <3 month intervals moving forward.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2021 Resolved
Child life jacket's stowage location was not labeled.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2021
Resolution: Item was corrected on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 September 2020 Resolved
The owner or managing operator shall make a vessel available for drydock examinations and internal structural examinations as required in 46 CFR 176.600. Due to your vessels current operational status, you failed to complete your required Drydock and Internal Structural Exam. Complete Credit Drydock and Internal Structural Exam prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2021
Resolution: Completed credit DDX/ISE.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 August 2020 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure and personnel injury. Rudder packing leaking excessively and not maintaining suitable watertight integrity for the protection of the vessel. 46 CFR 182.100.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 3 September 2020
Resolution: Rudder packing was tightened and vessel taken underway to verify no leaks in stearing gear or rudder packing. No leaks observed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 August 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts, U.S. Coast Pilot [name withheld] List. Vessel missing U.S. Coast Pilot, Charts have not been updated since 2017, and Coast Guard Light List has not been updated since 2018. 46 CFR 184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 September 2020
Resolved 25 September 2020
Resolution: Vessel O/O to provide Navigation Pubs upon operations in Spring 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 August 2020 Resolved
Each child lifejacket must be stowed in a location that is appropriately marked and separated from adult lifejackets so the child size lifejackets are not mistaken for adult lifejackets. Child size lifejackets are stowed forward and immediately next to the adult lifejackets, with no markings identifying the separation between the stacks of jackets. 46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 3 September 2020
Resolution: Child life jacket storage area was also inspected and found adequately marked to distiguish child size life jackets from adult size life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2019 Resolved
Fuel shut off valves shall be installed so as to be operable from outside the tank compartment. Shut valve located on the engine was seized and not operable. Provide this office with proof of operable fuel shut off valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2019
Resolved 27 May 2019
Resolution: Provide this office with valid proof of operation of fuel shut-off valve - ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2019 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Vessel had 3 lifejackets that were not in good and serviceable condition. Provide this office with proof of 3 additional lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2019
Resolved 27 May 2019
Resolution: Provide this office with valid proof of 3 brand new Type-I life jackets - ALL SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 April 2019 Resolved
A vessel must carry an approved first aid kit. Vessel's first aid kit contained multiple expired items including medicines and eye wash. Provide this office with proof of replacement items for the expired medicines and eye wash.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2019
Resolved 27 May 2019
Resolution: Provide this office with valid proof of brand new eye wash and associated medicine - ALL SAT.
Lifesaving › Lifefloat › Markings
Issued 29 May 2014 Resolved
46 CFR 160.010-4(n) The color of the buoyant apparatus must be primarily vivid reddish orange. The life float has been painted red. Repair to requirements.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 26 June 2014
Resolution: Buoyant Apparatus was repaired with approved repair kit. Inspected satisfactory.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 29 May 2014 Resolved
46 CFR 182.450 (e) The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. Fuel vent screen damaged. Replace or repair to original condition.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 16 June 2016
Resolution: STBD fuel vent was inspected and found to be 30x30 mesh as required.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 29 May 2014 Resolved
IMO Res A.658(16) Annex 2 (3.1) The brightness of the retro-reflective material when tested should be not less than 80% of its original installation. Retroreflactive material is worn. Replace with new as required.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 26 June 2014
Resolution: SOLAS tape applied to life jackets were more than 20% deterioration existed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 May 2014 Resolved
46 CFR 177.900 Deck rails must withstand a pointload of 200lbs applied in any direction. Rail courses broke loose on STBD side aft superstructure. Repair to original condition.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 26 June 2014
Resolution: STBD rail courses were inspected and found to be repaired satisfactory.
Lifesaving › Lifejacket/PFD (Type V) › Marking
Issued 29 May 2014 Resolved
46 CFR 185.604 (b) Each life jacket and ring buoy must be marked in clearly legible block captital letters with the vessel's name. Vessel name is worn on life ring and many PFDs. Repair as required.
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 26 June 2014
Resolution: Vessel name was repaired on lifering and life jackets as required. Inspected sat.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 May 2014 Resolved
46 CFR 183.350 (b) Each battery must be secured to protect against shifting with the roll and pitch of the vessel and free from exposure to water splash or spray. Both engine start batteries are installed in battery boxes on deck and the port battery box is full of water. remove water as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2014
Resolved 26 June 2014
Resolution: Battery box was inspected and found to be free of water.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 May 2014 Resolved
46 CFR 177.900 Deck rails must withstand a pointload of 200lbs applied in any direction. Hand rail loose due to missing bolt on port side hand rail stanchion forward of the embarkation station. Repair to original condition.
Action required: 15 - Rectify deficiencies by next port
Due 30 June 2014
Resolved 26 June 2014
Resolution: Port Hand Rail inspected to have been repaired satisfactory.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 19 June 2007 Resolved
Provide approved fire detection system or alternative system substitute.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 13 December 2007
Resolution: Owner installed CG approved pre-engineered fixed fire fighting system. Conducted inspection and test of system, sat.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 19 June 2007 Resolved
Provide plan for installation of approved fire detection system and log daily system checks of current system.
Due 15 July 2007
Resolved 13 December 2007
Resolution: Owner installed CG approved pre-engineered fixed fire fighting system. Conducted inspection and test of system, sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 June 2005 Resolved
Provide new 18' line for waterlight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2005
Resolved 9 September 2005
Construction/Loadline › Hull › Bracket
Issued 7 June 2005 Resolved
Install additional rails to meet 12" minimum distance between coarses.
Due 7 July 2005
Resolved 9 September 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 7 June 2005 Resolved
Replace portable CO2 bottle with one that is approved for marine use.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2005
Resolved 9 September 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 7 June 2005 Resolved
Replace mounting bracket for CO2 bottle in pilot house.
Due 7 July 2005
Resolved 9 September 2005
Lifesaving › Buoyant Apparatus
Issued 9 March 2004 Resolved
Prior to carrying passengers at night, renew waterlight for life float. LEGACY COMPONENT DESC: Waterlight
Due 23 March 2004
Resolved 10 March 2004
Operations/Management › Navigation Safety
Issued 9 March 2004 Resolved
Provide current US Coast Pilot. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 23 March 2004
Resolved 10 March 2004
Electrical › Lighting (service)
Issued 9 March 2004 Resolved
Replace or remove old lighting fixture without guard for light bulb. LEGACY COMPONENT DESC: Lighting Fixture
Due 9 April 2004
Resolved 10 March 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 12 March 2002 Resolved
RENEW CRACKED GLASS IN PORT SIDE PILOTHOUSE WINDOW.
Due 12 April 2002
Resolved 9 January 2003
Engineering
Issued 20 February 2001 Resolved
REPLACE CUTLASS BEARING.
Condition: Unknown
Due 20 February 2001
Resolved 20 February 2001
Lifesaving
Issued 4 March 1998 Resolved
PROVIDE A BRIGHT COLORED BOX FOR DISTRESS SIGNALS STENCILED "DISTRESS SIGNALS" IN 1/2" CONTRASTING COLORED LETTERS.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Lifesaving
Issued 4 March 1998 Resolved
REPLACE PAINTER FOR B/A.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Engineering
Issued 4 March 1998 Resolved
EMERGENCY FUEL OIL SHUT OFF MUST BE INSTALLED TO PROTECT THE OPERATOR FROM FLAME SHOULD IT NEED TO BE USED DURING A FIRE.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Engineering
Issued 4 March 1998 Resolved
INSTALL A KEEPER FOR THE THROTTLE CONTROL CABLE AT ENGINE.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Lifesaving
Issued 4 March 1998 Resolved
PROVIDE 1 ADDITIONAL FLASHLIGHT.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Construction/Loadline
Issued 19 February 1998 Resolved
PROPERLY SECURE (CAP OR VALVE) THRU HULL AT STBD SIDE AFT GUNWHALE.
Condition: Unknown
Due 31 March 1998
Resolved 9 March 1998
Accommodation/Occupational Safety
Issued 19 February 1998 Resolved
PROVE HANDRAIL STRENGTH IAW 46CFR177.900(B) 200LB POINT LOAD & 50 LB UNIFORM LOAD.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Construction/Loadline
Issued 19 February 1998 Resolved
REPLACE OR CAP OFF AFT BOTTOM THRU HULL.
Condition: Unknown
Due 31 March 1998
Resolved 9 March 1998
Navigation
Issued 7 March 1997 Resolved
Rules of the Road - outdated.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Fire Fighting
Issued 7 March 1997 Resolved
One B-I extinguisher needs to be serviced.
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Documentation
Issued 14 March 1991 Resolved
MISSING STABILITY LETTER
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Construction/Loadline
Issued 14 March 1991 Resolved
MISSING COVER FOR ANCHOR LINE THRU DECK PIPE.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Fire Fighting
Issued 14 March 1991 Resolved
ONE B-I HAND PORTABLE FIRE EXT. EXPENDED.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Fire Fighting
Issued 14 March 1991 Resolved
HAND PUMP NOT RIGGED FOR USE A HAND FIRE PUMP.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Engineering
Issued 14 March 1991 Resolved
VESSEL HAS FLEXA BLE FUEL HOSES IN EXCESS OF 30 INCHES.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Lifesaving
Issued 14 March 1991 Resolved
THREE (3) HAND RED FLARES EXPIRED USE DATE.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Fire Fighting
Issued 15 March 1990 Resolved
REPAIR/REPLACE CO2 FIRE EXT BRACKET
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Engineering
Issued 15 March 1990 Resolved
INSTALL DRIP PAN AND HEAT SHIELD ON RACOR FUEL FILTER. PARTS ARE AVAIL- ABLE FROM RACOR TO BE COMPLETED BY 6APR90
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Lifesaving
Issued 15 March 1990 Resolved
REPLACE LIFERING; INSTALL FLOAT LIGHT AND LINE
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Lifesaving
Issued 15 March 1990 Resolved
INSTALL 6-10 PERSON WEAKLINK ON LIFE FLOAT
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Lifesaving
Issued 15 March 1990 Resolved
STENCIL PPADDLE AND LIFEFLOAT WITH VSL NAME
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990

Casualty record · 1

11 October 2011Routine · role: Involved in a Marine Casualty · activity 4165867
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.