Records from 1993 to 2026. Most recent: inspection, 11 June 2026.
Inspection history · 32
11 June 2026
Annual Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8395656
5 January 2026
Damage Survey
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8290404
21 August 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8213212
9 August 2024
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7977992
14 June 2024
Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7934702
25 March 2024
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7884735
18 July 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7745717
20 September 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7563044
23 April 2022
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7442204
8 September 2021
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7307275
20 August 2020
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7038483
25 April 2020
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6944397
24 April 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6956216
14 August 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6783098
30 May 2019
Deficiency Check · Initial Certification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6703460
7 December 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6320154
6 November 2011
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4184770
13 April 2011
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3985615
18 February 2011
Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3949822
1 October 2006
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2790887
30 September 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2806509
24 November 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2252782
17 August 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2168910
16 July 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2135491
13 January 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1982821
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978930
29 May 2003
Uninspected Towing Vessel
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1808433
5 May 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1786786
14 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 8525
1 July 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 533076
9 June 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 500628
28 May 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 227669
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 June 2026
Resolved
A power-driven vessel underway shall exhibit: A sternlight. Vessel stern light was found to be inoperable. Repair or replace the stern light. The vessel is restricted to daylight-only operation until this deficiency is rectified.
33 CFR 83.23(a)(iv)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2026
Resolved 15 June 2026
Resolution: Stearn Light has been repaired/replaced.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 11 June 2026
Resolved
Each towing vessel must be fitted with a general alarm that: Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light. The general alarm flashing red light was inoperable when tested. Repair or replace engine room general alarm flashing red light.
46 CFR 143.235(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2026
Resolved 12 June 2026
Resolution: Engine room general alarm light has been repaired/replaced
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 June 2026
Resolved
Each remote valve control must be marked in clearly legible letters, indicating the purpose of the valve and the way to operate it. The remote fuel shutoff valve controls for the port and starboard fuel tanks did not have posted directions or markings indicating how to operate them. Provide clear operating directions on each remote fuel shutoff valve control.
46 CFR 143.260(e)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2026
Resolved 12 June 2026
Resolution: Clear operating directions on each remote fuel shutoff valves are in place.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 August 2025
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line a remote fuel shutoff valve must be fitted and operable from a safe place outside the space where the valve is installed.
The port side remote fuel shutoff valve was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 August 2025
Resolution: Cable was repaired and an operation test was witnessed by attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Generator switchboard not fitted with an interlock to prevent paralleling of generators.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 August 2025
Resolution: Interlocking device was installed by crew and operation was witnessed by attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Breaker box in engine room contained open slots with no filler plates installed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2025
Resolved 27 August 2025
Resolution: Filler plates were installed in open slots.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 June 2024
Resolved
The fuel shut off valve must be operable from a safe place outside the space where the valve is installed. Witnessed the starboard fuel shut off valve broke. Crew replaced the valve and retested to the satisfaction of attending U.S. Coast Guard Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 16 July 2024
Resolution: Crew was able to fix starboard fuel shut off valve while Coast Guard marine inspectors were still on board. Retested to the satisfaction of attending USCG marine inspector.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 20 August 2020
Resolved
Each ship subject to the Bridge To Bridge Act must have on board a radio operator who holds a restricted telephone operator permit or higher.
The Master was unable to find his Radio Operator Permit at the time of inspection.
Action required: 10 - Deficiency Rectified
Resolved 20 August 2020
Resolution: Company emailed proof of Radio Operator Permit to SEC Hou-Gal ITV.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 30 May 2019
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel. The vessel's Port steering pump trips when it is fully warm.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 June 2019
Resolved 4 June 2019
Resolution: Completed repairs and MIs witnessed satisfactory steering test.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 30 May 2019
Resolved
Each towing vessel must be fitted with a general alarm in the engine room that has a supplemental flashing red light. The flashing red light for the general alarm in the engine room is inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 June 2019
Resolved 2 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 May 2019
Resolved
Towing vessels must be equipped with a search light controllable from the vessel's operating station and capable of illuminating objects at a distance of at least two times the tow.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 June 2019
Resolved 2 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2019
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 psi MAWP must have one or more spring-loaded relief valves, which, the total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP by more than 10 percent. Currently, both pressure vessels in the engine room are fitted with relief valves set to 225 psi where the MAWP of the pressure vessels are 200 MAWP.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 June 2019
Resolved 2 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 30 May 2019
Resolved
Each liferaft must be arranged for float free launching. A hydrostatic release unit used in a float free arrangement must be approved under 46 CFR 160.162.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 June 2019
Resolved 2 June 2019
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 30 May 2019
Resolved
Electrical systems and equipment must function properly and minimize fire and shock hazards. There is currently a push cigarette lighter spliced into existing electrical wire in the galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 2 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 May 2019
Resolved
The frame or support of any semi-portable fire extinguishers fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. The vessel's 160 B:C semi portable extinguisher is currently not secured to any frame or support.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 2 June 2019
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 30 May 2019
Resolved
Each EAP education program must include display and distribution of informational material, community service hot-line telephone number for crew member assistance, and employers policy regarding drug and alcohol use in the workplace. The vessel currently does not have any EAP information posted in public spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 2 June 2019
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 May 2019
Resolved
Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. The bilge slop tank in the engine room currently does not have a flame screen installed on the goose-neck vent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 2 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2019
Resolved
Each lifebuoy with a floating electric water light must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the water light around the body of the lifebuoy. The port and starboard bridge wing lifebuoy lights are less than 3 feet long.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 2 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2019
Resolved
Towing vessels greater than 26 ft must have at least two lifebuoys fitted with a floating electric water light approved under 46 CFR 161.010 or 161.110. The vessel's starboard side lifebuoy light is inoperable. Crew replaced lifebuoy light during inspection.
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2019
Resolved
At least one lifebuoy must have a lifeline. If more than one lifebuoy is carried, at least one must not have a lifeline attached. All vessel lifebuoys were fitted with lifelines. Crew removed lifeline from the port side lifebuoy.
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 30 May 2019
Resolved
Individuals, who are not crew members, on board a towing vessel must receive a safety orientation prior to getting underway or as soon as practicable thereafter. The crew did not conduct safety orientation to marine inspectors or technician prior to getting underway.
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
Communications
Issued 13 January 2004
Resolved
No radio license held by anyone onboard.
Due 27 January 2004
Resolved 1 April 2004
Resolution: Radio License aquired.
Navigation
Issued 13 January 2004
Resolved
No current updates on charts. LEGACY COMPONENT DESC: Charts
Due 27 January 2004
Resolved 6 February 2004
Resolution: Charts updated
Pollution Prevention/Response › Prevention Equipment
Issued 13 January 2004
Resolved
Posted operating intsructions missing. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Due 27 January 2004
Resolved 6 February 2004
Resolution: Instructions posted.
Lifesaving › Lifejacket/PFD (General)
Issued 13 January 2004
Resolved
Vessel name missing on PFD's and liferings. Tape missing on liferings.
Due 27 January 2004
Resolved 6 February 2004
Resolution: Names/tape placed on lifesaving equipment.