MAURY USCG vessel records Sign in
← All vessels

PIKE

PIKE is a 1980 offshore supply vessel. The Coast Guard has recorded 31 inspections since 1989, most recently in June 2012, along with 19 deficiencies.

Records from 1989 to 2012. Most recent: inspection, 14 June 2012.

Built
1980
Last inspected
14 June 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD4678
188607
Flag
UNITED STATES
366817580, 367145070, 367147950, 367627440 (licence lapsed)
Maury page id
psix-188607

Inspections, by type

…with no type recorded5
Years with a record 18 calendar years (1989–2012)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDH5385MMSI 367627440 · expired · compulsorily equipped · granted 14 June 2014, cancelled 17 August 2024
WDD4678MMSI 367147950 · expired · compulsorily equipped · granted 31 October 2006, cancelled 31 December 2016
WDD4467MMSI 367145070 · cancelled · voluntarily equipped · granted 12 October 2006, cancelled 17 October 2006
WDA5204MMSI 366817580 · cancelled · compulsorily equipped · granted 6 July 2001, cancelled 31 July 2006 · licensed under a name not among this hull’s recorded names (not shown)
WCP4371MMSI not assigned · expired · compulsorily equipped · granted 30 June 1998, cancelled 19 February 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MS INEZ Passenger (Inspected) · MISLE 49370 · 27 November 1996 · activity 181948

Inspection history · 31

14 June 2012 Examination of Repairs · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4344083
24 February 2011 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3951971
26 July 2007 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3008085
24 July 2007 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3005980
31 January 2006 Internal Structural Exam · Hull Examination · COI Inspection · Examination of Repairs · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2576522
7 June 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1628753
17 April 2001 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366255
6 June 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399392
6 August 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462770
16 May 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 173738
21 May 1998 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409881
6 February 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413119
28 January 1997 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1101324
27 November 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 181948
27 November 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 223840
9 May 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088129
22 March 1996 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447552
26 August 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1190033
25 August 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1182453
26 January 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396237
20 January 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 870976
11 July 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 197936
11 July 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 751807
29 September 1993 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373940
20 September 1993 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1148625
12 November 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469393
7 October 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 940771
12 September 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 932854
14 September 1990 Re-Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234488
7 May 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904138
14 September 1989 Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899078

Deficiency record · 19

Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 14 June 2012 Resolved
Light bulb on the low hydraulic alarm for the jacking system was not operational
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 14 June 2012 Resolved
Replace light fixture covers in stbd engine room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2012
Engineering › Lubricating Oil Service System › Piping
Issued 14 June 2012 Resolved
Hydrolic piping for vessel jacking system had a leak in the stbd engine room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2012
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 14 June 2012 Resolved
vessel needs a shaft sheet that converts engine RPM to shaft RPM
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2012
Electrical › Electric Generation Source (emergency) › Switch
Issued 14 June 2012 Resolved
vessel had a switch on board that would allow the VHF/SSB to run directly from the ships main 12 volt system. When main 12 volt system goes down the radios do not go directly to battery power if the switch is turned in the up position. Vessel rep will remove the switch so battery backup is automatic in the event of a power loss.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2012
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 31 January 2006 Resolved
Provide updated operations manual for vessel to include all required drawings.
Action required: 705 - Other - as specified
Due 6 May 2008
Resolved 18 June 2009
Resolution: Included all required drawings in the operations manual
Engineering › Lubricating Oil Service System › Piping
Issued 31 January 2006 Resolved
Provide hydraulic jacking system plans,component verification of suitability to system pressure and fail safe features as outlined in CG-543 to be included in Ops manual.
Action required: 705 - Other - as specified
Due 6 May 2008
Resolved 18 June 2009
Resolution: Fail safe features are outlined in Ops manual
Construction/Loadline › Structures › Deck Plating
Issued 31 January 2006 Resolved
01 level deck plate IWO E/R fidley holed, make temp repairs and conduct permenant repairs at next drydock, area is above main deck and weathertight only.
Action required: 705 - Other - as specified
Due 6 March 2011
Resolved 24 February 2011
Lifesaving
Issued 6 August 1999 Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District's policy ltr."Rescue Boat Requirements on Offshore Supply Vessels" dated 12NOV98 to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Engineering
Issued 22 March 1996 Resolved
INSTALL RELIEF VALVES ON BOTH PORT AND STBD AIR LINES BETWEEN THE COMPRESSOR'S OUTLET AND THE FIRST ISOATION VALVE NO LATER THAN 22APR96.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Documentation
Issued 14 September 1989 Resolved
VESSEL TO BE READMEASURED OR MANNING WILL BE INCREASED.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Unknown
Issued 14 September 1989 Resolved
SUBMIT PLANS AND INSTALL TILT ALARMS.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Navigation
Issued 14 September 1989 Resolved
INSTALL STEERING ALARM SYSTEM.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Navigation
Issued 14 September 1989 Resolved
INSTALL RUDDER INDICATORS.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Lifesaving
Issued 14 September 1989 Resolved
INSTALL FIXED EMBARCATION LADDER.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Navigation
Issued 14 September 1989 Resolved
INSTALL SSB RADIO.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Lifesaving
Issued 14 September 1989 Resolved
PROVIDE CG APPROVED LINE THROWING APPLICANCE.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Documentation
Issued 14 September 1989 Resolved
SUBMIT FOR APPROVAL STABILITY CALCULATION AND OPERATIONAL MANUAL TO MARINE SAFTY CENTER.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989
Documentation
Issued 14 September 1989 Resolved
SUBMIT FOR APPROVAL THE FOLLOWING PLANS TO OXMI MORGAN CITY, (1) OUT AND INBOARD PROFILE PLANS,(2) GENERAL ARRANGEMENT,(3) SAFETY AND FIRE CONTROL PLAN, (4) HYDRAULIC SYSTEMS, (5) INFORMATION AND INSTALLATION OF LEGS.
Condition: Unknown
Due 14 September 1989
Resolved 14 September 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.