Records from 2001 to 2025. Most recent: inspection, 9 August 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 32
9 August 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8205942
24 June 2025
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8165900
16 September 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8005192
7 September 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7787232
16 August 2023
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7769876
30 July 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7763515
6 June 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704339
5 December 2022
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7604076
16 June 2022
Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7478108
28 October 2021
Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7341459
7 October 2021
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7328564
28 July 2021
Drydock Extension · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7328247
14 October 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7076780
16 April 2020
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6939987
3 October 2019
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6827028
15 July 2019
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6751268
1 October 2018
Annual Inspection · In-Service Inspection · Examination of Repairs · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6552947
26 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6549117
12 June 2018
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6443443
12 June 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6448060
14 February 2018
Liferaft Servicing
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6355248
18 January 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339349
18 January 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6339487
17 January 2018
Damage Survey · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6340471
10 August 2017
In-Service Inspection · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6248579
24 May 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6154490
19 December 2016
Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6060262
27 May 2016
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5888231
11 May 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5881795
18 April 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5856909
5 April 2016
Administrative Inspection · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5847419
26 January 2016
Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5806296
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2025
Resolved
"A dry exhaust pipe must: be provided with noncombustible hangers and blocks for support." Starboard exhaust pipe found unsecured in lazarette. Repair hanger.
46 CFR 119.430(g)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 4 August 2025
Resolution: Recieved photo evidence of STBD Exhaust Hangar w/ welded bracket and attachment hardware secured in place. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 June 2025
Resolved
"On a vessel without overnight accommodations... the fire pump must be capable of delivering a single hose stream from the highest hydrant... at a pilot tube pressure of 50psi." Stbd fire pump recorded pressure less than 30psi. Ensure pump can operate at required pressure.
46 CFR 118.300(b)
Action required: 10 - Deficiency Rectified
Resolved 24 June 2025
Resolution: Showed pressure at 50psi
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2025
Resolved
"Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottoms." Trash cans are made of plastic combustible material. Replace trash cans with noncombustible for interior.
46 CFR 116.405(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 7 August 2025
Resolution: Provided details showing noncombustible design
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2025
Resolved
"The discharge ends of fuel tank vent pipes must be fitted with removable flame screens... of corrosion resistant wire of at least 30 x 30 mesh." Port side fuel vent pipe found without proper flame screen. Install satisfactory flame screen.
46 CFR 119.450(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 4 August 2025
Resolution: Received photo evidence of renewed flame screen at port fuel vent. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 June 2025
Resolved
"Each storage cylinder must meet the requirements of 147.60 in Subchapter N of this chapter." CO2 cylinders on port side found corroded. Replace prior to next credit dry dock.
46 CFR 118.410(c)(9)
Action required: 705 - Other - as specified
Resolved 9 August 2025
Resolution: Cylinders have been replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 September 2024
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has lapsed on their annual inspection date. Issued prior to passengers to be rectified upon completion of inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2024
Resolution: Annual inspection completed.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 16 June 2022
Resolved
Provide repair plan for the 2 cracks found in the frame of the fwd port second void space
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 June 2022
Resolved
Submit servicing records for fixed fire extinguishers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2022
Resolved
Port and Starboard atf access door locks are inop.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 June 2022
Resolved
Remove hazardous materials located at the port embarkation area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 June 2022
Resolved
Heater in potable water room has exposed wires. Tag out until repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 June 2022
Resolved
Fuel sight glass located in port electrical room is missing protective device
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2022
Resolved
M.I observed potable water leaking from containment
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2022
Resolved
250 gal portable potable added on board
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 October 2021
Resolved
Observed trouble alarm on "zone #2 passenger area tier 2". The single fire smoke detector was unable to be tested on said passenger area. Operator has indicated an additional deck hand will be tasked to conduct fire watch rounds while underway with passengers and log rounds into bridge log book. Vessel will be required to provide fire panel technician report and confirm proper repairs have been made. Vessel given 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2021
Resolved 25 October 2021
Resolution: Verified proper operation of system.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 October 2021
Resolved
The original COD was not on board the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 October 2021
Resolved 14 October 2021
Resolution: VSL sent image of COD.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 October 2018
Resolved
During inspection it was noted the vessel had a cracked weld in the starboard stern tube in the lazarette space allowing water ingress. Vessel must provide a repair proposal to the OCMI for review and approval.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2018
Resolved 18 October 2018
Resolution: Repair plan submitted and approved. Repairs completed and tested. All sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2018
Resolved
During inspection it was noted that the port and starboard shaft seals were leaking water at an excessive rate. Vessel must replace shaft seals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2018
Resolved 9 November 2018
Resolution: Shaft seals were reinspected while underway. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2018
Resolved
During inspection it was noted that the vessel had a reading of 2 AMPS on their ground detection system. Vessel must identify and secure the ground.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2018
Resolved 9 November 2018
Resolution: Inspectors verified the ground was clear.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 September 2018
Resolved
Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 June 2022
Construction/Loadline › Hull › Side Shell
Issued 12 June 2018
Resolved
Vessel allided with the 35th street pier and puncutured a hole in the port outboard hull plate 6' above the waterline. Vessel must make proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2018
Resolution: Final weld tested satisfactorily.
Construction/Loadline › Hull › Hull Plating
Issued 18 January 2018
Resolved
Vessel to hull vessel for damage survey, submit repair proposal and make proper repairs to damaged hull plate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 January 2018
Resolution: Vessel made proper repairs.
Operations/Management › Vessel Activity › Other
Issued 21 July 2017
Resolved
Following major engine remodification, schedule a return to zone inspection with local OCMI prior to carrying passenger.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2017
Resolved 11 August 2017
Resolution: Completed COI inspection.
Lifesaving › Inflatable Liferafts › Capacity
Issued 21 July 2017
Resolved
Provide on board all required life rafts prior to carrying passengers, currently on board are only sufficient for transit from New Orleans to New Jersey.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2017
Resolved 10 August 2017
Resolution: Verified proper life saving equipment.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 21 July 2017
Resolved
Verify the drug and alcohol program for the vessel.
Due 1 August 2017
Resolved 10 August 2017
Resolution: Verified DAPI requirements.
Operations/Management › Vessel Activity › Underway
Issued 21 July 2017
Resolved
Vessel to follow submitted transit plan to New jersey from New Orleans.
Action required: 705 - Other - as specified
Due 1 August 2017
Resolved 10 August 2017
Resolution: Vessel made it to New Jersey via transit plan.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 21 July 2017
Resolved
Complete MSC approval of the design and installation of electronic propulsion control system prior to carrying passegners.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2017
Resolution: Completed DVTP.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 July 2017
Resolved
Conduct man overbaord drill to satisfaction of attending Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2017
Resolved 11 August 2017
Resolution: Witnessed satisfactory drills with vessel's crew.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 18 April 2016
Resolved
01) Properly repair head gasket leak on main engine manifold.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 25 April 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 18 April 2016
Resolved
02) Properly raise and fix CO2 bottles at least 2 inches above deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 21 June 2016