MAURY USCG vessel records Sign in
← All vessels

SEASTREAK NEW YORK

SEASTREAK NEW YORK is a 2001 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 2001, most recently in August 2025, along with 68 deficiencies and 9 casualty investigations between 2001 and 2018.

Records from 2001 to 2025. Most recent: inspection, 9 August 2025.

Built
2001
Last inspected
9 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8967620 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE3997
Flag
UNITED STATES
367347130
Maury page id
psix-18956

Inspections, by type

…with no type recorded15
Years with a record 24 calendar years (2001–2025)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)127.3 ft × 34.4 ft × 11.0 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)127.3 ft × 34.4 ft × 11.0 ft
ITC tonnagegross 431 / net 159
BuilderGLADDING-HEARN SHIPBLBG · SOMERSET, MA, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portATLANTIC HIGHLANDS, NJ
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
431 - Convention (Subpart B), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
159 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE3997MMSI 367347130 · active · compulsorily equipped · granted 3 April 2018, expires 3 April 2028
WDA4972MMSI 366815130 · expired · compulsorily equipped · granted 12 June 2001, cancelled 13 August 2011
WDA4823MMSI 366813510 · cancelled · compulsorily equipped · granted 30 May 2001, cancelled 29 October 2001
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 79

9 August 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8205942
24 June 2025 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8165900
16 September 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8005192
7 September 2023 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7787232
16 August 2023 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7769876
30 July 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7763515
6 June 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704339
5 December 2022 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7604076
16 June 2022 Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7478108
28 October 2021 Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7341459
7 October 2021 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7328564
28 July 2021 Drydock Extension · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7328247
14 October 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7076780
16 April 2020 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6939987
3 October 2019 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6827028
15 July 2019 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6751268
1 October 2018 Annual Inspection · In-Service Inspection · Examination of Repairs · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6552947
26 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6549117
12 June 2018 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6443443
12 June 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6448060
14 February 2018 Liferaft Servicing
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6355248
18 January 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339349
18 January 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6339487
17 January 2018 Damage Survey · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6340471
10 August 2017 In-Service Inspection · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6248579
24 May 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6154490
19 December 2016 Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6060262
27 May 2016 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5888231
11 May 2016 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5881795
18 April 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5856909
5 April 2016 Administrative Inspection · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5847419
26 January 2016 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5806296
28 September 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5730824
8 May 2014 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4853430
8 May 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4853639
10 July 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4374401
5 July 2012 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4368541
24 May 2012 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4320515
26 January 2012 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4231272
14 September 2011 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4143159
2 November 2010 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3884887
25 October 2010 Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3877491
22 October 2010 Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3875192
17 October 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3884964
6 October 2010 Plan Review (Other than "T") · Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3865010
23 February 2010 Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3712657
12 May 2009 Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3472644
10 March 2009 Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3434770
12 November 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3361767
12 August 2008 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3296167
23 June 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3252335
7 April 2008 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3178871
18 June 2007 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2965573
10 April 2007 Internal Structural Exam · Drydock Extension
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2904585
30 July 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2729877
9 June 2006 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2674621
4 May 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2640450
22 July 2005 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2435839
22 July 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2474055
22 June 2005 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2398760
11 May 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2354800
1 February 2005 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2284195
26 July 2004 Annual Inspection · MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2145239
2 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1957524
24 June 2003 Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1825234
2 April 2003 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1785057
24 March 2003 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1761944
13 January 2003 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1729802
17 July 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1648062
18 June 2002 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1632361
3 June 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1625790
3 April 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1600607
28 September 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 103808
28 September 2001 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1452855
30 July 2001 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1069580
13 June 2001 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1066315
12 June 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1833765
26 April 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1063878
16 April 2001 Deadweight Survey · Hull Examination · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1464402

Deficiency record · 68

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2025 Resolved
"A dry exhaust pipe must: be provided with noncombustible hangers and blocks for support." Starboard exhaust pipe found unsecured in lazarette. Repair hanger. 46 CFR 119.430(g)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 4 August 2025
Resolution: Recieved photo evidence of STBD Exhaust Hangar w/ welded bracket and attachment hardware secured in place. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 June 2025 Resolved
"On a vessel without overnight accommodations... the fire pump must be capable of delivering a single hose stream from the highest hydrant... at a pilot tube pressure of 50psi." Stbd fire pump recorded pressure less than 30psi. Ensure pump can operate at required pressure. 46 CFR 118.300(b)
Action required: 10 - Deficiency Rectified
Resolved 24 June 2025
Resolution: Showed pressure at 50psi
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2025 Resolved
"Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottoms." Trash cans are made of plastic combustible material. Replace trash cans with noncombustible for interior. 46 CFR 116.405(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 7 August 2025
Resolution: Provided details showing noncombustible design
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2025 Resolved
"The discharge ends of fuel tank vent pipes must be fitted with removable flame screens... of corrosion resistant wire of at least 30 x 30 mesh." Port side fuel vent pipe found without proper flame screen. Install satisfactory flame screen. 46 CFR 119.450(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 4 August 2025
Resolution: Received photo evidence of renewed flame screen at port fuel vent. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 June 2025 Resolved
"Each storage cylinder must meet the requirements of 147.60 in Subchapter N of this chapter." CO2 cylinders on port side found corroded. Replace prior to next credit dry dock. 46 CFR 118.410(c)(9)
Action required: 705 - Other - as specified
Resolved 9 August 2025
Resolution: Cylinders have been replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 September 2024 Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has lapsed on their annual inspection date. Issued prior to passengers to be rectified upon completion of inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2024
Resolution: Annual inspection completed.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 16 June 2022 Resolved
Provide repair plan for the 2 cracks found in the frame of the fwd port second void space
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 June 2022 Resolved
Submit servicing records for fixed fire extinguishers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2022 Resolved
Port and Starboard atf access door locks are inop.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 June 2022 Resolved
Remove hazardous materials located at the port embarkation area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 June 2022 Resolved
Heater in potable water room has exposed wires. Tag out until repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 June 2022 Resolved
Fuel sight glass located in port electrical room is missing protective device
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2022 Resolved
M.I observed potable water leaking from containment
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2022 Resolved
250 gal portable potable added on board
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2022
Resolved 15 July 2022
Resolution: Vsl submitted rectification documentation uploaded in deficiencies details tab.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 October 2021 Resolved
Observed trouble alarm on "zone #2 passenger area tier 2". The single fire smoke detector was unable to be tested on said passenger area. Operator has indicated an additional deck hand will be tasked to conduct fire watch rounds while underway with passengers and log rounds into bridge log book. Vessel will be required to provide fire panel technician report and confirm proper repairs have been made. Vessel given 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2021
Resolved 25 October 2021
Resolution: Verified proper operation of system.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 October 2021 Resolved
The original COD was not on board the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 October 2021
Resolved 14 October 2021
Resolution: VSL sent image of COD.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 October 2018 Resolved
During inspection it was noted the vessel had a cracked weld in the starboard stern tube in the lazarette space allowing water ingress. Vessel must provide a repair proposal to the OCMI for review and approval.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2018
Resolved 18 October 2018
Resolution: Repair plan submitted and approved. Repairs completed and tested. All sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2018 Resolved
During inspection it was noted that the port and starboard shaft seals were leaking water at an excessive rate. Vessel must replace shaft seals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2018
Resolved 9 November 2018
Resolution: Shaft seals were reinspected while underway. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2018 Resolved
During inspection it was noted that the vessel had a reading of 2 AMPS on their ground detection system. Vessel must identify and secure the ground.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2018
Resolved 9 November 2018
Resolution: Inspectors verified the ground was clear.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 September 2018 Resolved
Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 June 2022
Construction/Loadline › Hull › Side Shell
Issued 12 June 2018 Resolved
Vessel allided with the 35th street pier and puncutured a hole in the port outboard hull plate 6' above the waterline. Vessel must make proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2018
Resolution: Final weld tested satisfactorily.
Construction/Loadline › Hull › Hull Plating
Issued 18 January 2018 Resolved
Vessel to hull vessel for damage survey, submit repair proposal and make proper repairs to damaged hull plate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 January 2018
Resolution: Vessel made proper repairs.
Operations/Management › Vessel Activity › Other
Issued 21 July 2017 Resolved
Following major engine remodification, schedule a return to zone inspection with local OCMI prior to carrying passenger.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2017
Resolved 11 August 2017
Resolution: Completed COI inspection.
Lifesaving › Inflatable Liferafts › Capacity
Issued 21 July 2017 Resolved
Provide on board all required life rafts prior to carrying passengers, currently on board are only sufficient for transit from New Orleans to New Jersey.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2017
Resolved 10 August 2017
Resolution: Verified proper life saving equipment.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 21 July 2017 Resolved
Verify the drug and alcohol program for the vessel.
Due 1 August 2017
Resolved 10 August 2017
Resolution: Verified DAPI requirements.
Operations/Management › Vessel Activity › Underway
Issued 21 July 2017 Resolved
Vessel to follow submitted transit plan to New jersey from New Orleans.
Action required: 705 - Other - as specified
Due 1 August 2017
Resolved 10 August 2017
Resolution: Vessel made it to New Jersey via transit plan.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 21 July 2017 Resolved
Complete MSC approval of the design and installation of electronic propulsion control system prior to carrying passegners.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2017
Resolution: Completed DVTP.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 July 2017 Resolved
Conduct man overbaord drill to satisfaction of attending Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2017
Resolved 11 August 2017
Resolution: Witnessed satisfactory drills with vessel's crew.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 18 April 2016 Resolved
01) Properly repair head gasket leak on main engine manifold.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 25 April 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 18 April 2016 Resolved
02) Properly raise and fix CO2 bottles at least 2 inches above deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 21 June 2016
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 14 September 2011 Resolved
#4 MDE audible alarms on bridge not functioning.
Action required: 705 - Other - as specified
Due 28 September 2011
Resolved 16 September 2011
Resolution: Vessel proved properation of #4 MDE bridge alarm.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 2 November 2010 Resolved
CG835 issued to provide L/O shut down and means to test for all main engines.
Action required: 705 - Other - as specified
Due 1 January 2011
Resolved 14 September 2011
Resolution: Issued in error.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 25 October 2010 Resolved
Conduct satisfactory sea trials to the satisfaction of the attending Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2010
Resolved 2 November 2010
Resolution: Sea trial satisfactory
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 6 October 2010 Resolved
Submit operations manual to local OCMI for approval for all high speed ferries operating at speeds of 30 knts or more loaded.
Action required: 705 - Other - as specified
Due 20 October 2010
Resolved 25 October 2010
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 6 October 2010 Resolved
All high speed ferries operating at speeds of 30 knts or more loaded are restricted to having no less than one licensed Master and one licensed mate on the bridge at all times until operations manual is approved by local OCMI.
Action required: 705 - Other - as specified
Resolved 25 October 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 10 March 2009 Resolved
Prove proper operation of #3 Aft Starboard Main Diesel Engine and provide technical repair report prior to carrying passengers for hire to the satisfaction of an attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2009
Resolved 16 March 2009
Engineering › Diesel Engine (auxiliary) › Governor
Issued 18 June 2007 Resolved
Repair the Back-up mode manual switch for the RPM on the #3 MDE.
Condition: Improper/Lack of Maintenance
Due 25 July 2007
Resolved 6 September 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 June 2007 Resolved
Make permanent repairs to broken window on the lower level fwd port side cabin.
Condition: Damaged By Earlier Event
Due 25 July 2007
Resolved 29 August 2007
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 17 November 2006 Resolved
33U.S.C.1321(j)(5)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge. 33U.S.C.1321(j)(5)(D)(iii)-The NTVRP correspondence identifies an unclassified oil spill removal organization (OSRO) for the New York COTP zone, and does not identify OSROs in the plan.
Due 17 December 2006
Resolved 15 January 2009
Resolution: NTVRP plan #04155 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.
Engineering › Non-conventional Propulsion/Steering › Nozzle (jet)
Issued 9 June 2006 Resolved
#4 jet back up control is not working for left and right movement. Make repairs to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 9 July 2006
Resolved 9 August 2006
Stability › Weathertight Integrity › General
Issued 22 July 2005 Resolved
Cracked S/S fwd bridge window due to faulty electrical switch in defroster system.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2005
Resolution: Replaced Same.
Navigation › Piloting/Steering › US Coast Pilot
Issued 22 June 2005 Resolved
Provide current (2005) version of Coast Pilot.
Action required: 705 - Other - as specified
Due 3 July 2005
Resolved 6 July 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 June 2005 Resolved
Provide current (2005) version of Light list
Action required: 705 - Other - as specified
Due 3 July 2005
Resolved 6 July 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 June 2005 Resolved
V/W Bow Stbd side rail stanchion #3 as discussed.
Action required: 705 - Other - as specified
Due 3 July 2005
Resolved 6 July 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 July 2004 Resolved
Found 7 bad lamps on the emergency (24 vdc) circuit, 4 in the port E/R, 1 in each jet room, & 1 on the aft main deck weatherdeck. Replace lamps.
Action required: 705 - Other - as specified
Due 2 August 2004
Resolved 24 August 2004
Resolution: Received a letter from the vessels master ([name withheld], Lic. # 907409) dated 8/23/04 stating all non working light bulbs and all emergency lighting is in working condition.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 June 2003 Resolved
Properly install main engine block heaters (wiring) LEGACY COMPONENT DESC: Block
Due 4 July 2003
Resolved 8 July 2003
Resolution: Witnessed permanent installation of block heaters.
Construction/Loadline › Structures
Issued 24 June 2003 Resolved
Make repairs to deck plating at fwd bow ramp (stbd side) LEGACY COMPONENT DESC: Deck Plating
Due 4 July 2003
Resolved 8 July 2003
Resolution: Witnessed repair to deck plating.
Accommodation/Occupational Safety › Occupational Safety
Issued 24 June 2003 Resolved
Provide lagging on Main Engine exhaust iwo turbo charger (port, fwd) LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 4 July 2003
Resolved 8 July 2003
Resolution: Witnessed repair to lagging on main engine.
Lifesaving › Inflatable Liferafts
Issued 3 April 2002 Resolved
Vsl. restricted to NY Lakes, Bays and Sounds Route until completion of liferaft annual serivice change out. Vsl. is to have liferaft capacity for no less than 300 persons. LEGACY COMPONENT DESC: Carriage Requirement
Due 3 May 2002
Resolved 18 June 2002
Resolution: Changed route at owners request to Lakes, Bays and Sounds.
Construction/Loadline
Issued 28 September 2001 Resolved
PROCEED TO DRYDOCK, MAKE PERMANENT AND PROPER REPAIRS TO THE STBD HULL TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR. NO COMMERCIAL OPS UNTIL REPAIRS ARE INSPECTED AND APPROVED BY THE ATTENDING USCG MI.
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Engineering
Issued 28 September 2001 Resolved
PROCEED TO DRYDOCK, MAKE PERMANENT AND PROPER REPAIRS TO THE STBD AFT MAIN DIESEL ENGINE TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR. NO COMMERCIAL OPS UNTIL REPAIRS ARE INSPECTED AND APPROVED BY A USCG MI.
Condition: Unknown
Due 15 October 2001
Resolved 15 October 2001
Fire Fighting
Issued 28 September 2001 Resolved
PROVIDE PROOF OF REPAIRS AND SERVICING OF STBD ENGINE ROOM CO2 SYSTEM AND HEAT DETECTION SYSTEM. NO COMMERCIAL OPS UNTIL CO2 SYSTEM AND HEAT DETECTION SYSTEM IS SERVICED AND FULLY OPERATIONAL.
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Documentation
Issued 28 September 2001 Resolved
SUBMIT A CG-2692 TO USCG ACTIVITIES NEW YORK FOR THE FIRE IN THE STBD ENGINE ROOM.
Condition: Unknown
Due 3 October 2001
Resolved 3 October 2001
Engineering
Issued 13 June 2001 Resolved
MAKE PERMANENT REPAIRS TO THE BLOWN OIL SEAL GASKET ON THE #1 MDE (PORT). THE MASTER SHALL FAX A COPY OF THE ENGINE SERVICING REPORT AND A STATEMENT OF COMPLETION OF A SATISFACTORY OPERATIONAL TEST OF THE ENGINE TO THE [name withheld].
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Fire Fighting
Issued 26 April 2001 Resolved
PROPERLY STENCIL EMERGENCY FIRE PUMP STARTS ON MAIN DECK, IWO FIRE STATIONS1 AND 2.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Documentation
Issued 26 April 2001 Resolved
PROVIDE REGUALTORY TONNAGE ON COD. CORRECTION MUST BE MADE BY THE VESSEL DOCUMENTATION CENTER.
Condition: Unknown
Due 26 August 2001
Resolved 18 June 2002
Resolution: Provided proper equipment.
Fire Fighting
Issued 26 April 2001 Resolved
RELOCATE FWD ENGINE ROOM CO2 DISCHARGE HORNS SO THAT IT IS NOT IMPEDED BY THE VENT DUCTING.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Lifesaving
Issued 26 April 2001 Resolved
POST THE STATION BILL ON EACH DECK.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Lifesaving
Issued 26 April 2001 Resolved
POST THE EMERGENCY INSTRUCTION LIST ON EACH DECK.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Lifesaving
Issued 26 April 2001 Resolved
INSTALL ACCEPTABLE POTABLE WATER HOSES.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Navigation
Issued 26 April 2001 Resolved
INSTALL A LARGER SCREEN FOR THE ELECTRIC CHART PLOTTER.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Fire Fighting
Issued 26 April 2001 Resolved
MAKE THE P/S SWITCHBOARD ROOMS SMOKE TIGHT.
Condition: Unknown
Due 26 August 2001
Resolved 3 June 2002
Lifesaving
Issued 26 April 2001 Resolved
DEVELOP AN OPERATIONS MANUAL FOR THE VESSEL, AND SUBMIT A COPY TO THE [name withheld] FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Deck/Cargo
Issued 26 April 2001 Resolved
INSTALL AN ANCHOR LINE OF THE APPROPRIATE LENGTH AND SIZE. LENGTH SHOULD BE3 TIMES THE DEEPEST DEPTH OF WATER IN THE VESSELS OPERATING AREA.
Condition: Unknown
Due 26 August 2001
Resolved 18 June 2002
Resolution: Provided proper equipment.
Electrical
Issued 26 April 2001 Resolved
INSTALL A LOCKING PIN OR OTHER SUITABLE METHOD TO PREVENT ACCIDENTAL TRIPPING OF THE GENSET BREAKERS IN THE P/S ENGINE ROOMS.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Lifesaving
Issued 16 April 2001 Resolved
CONDUCT AND LOG CREW TRAINING AS PER 46 CFR 122.420 PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Lifesaving
Issued 16 April 2001 Resolved
CONDUCT FIRE DRILL WITH ASSIGNED CREW TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Lifesaving
Issued 16 April 2001 Resolved
CONDUCT MAN OVERBOARD DRILL WITH ASSIGNED CREW TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001

Casualty record · 9

12 June 2001Routine · role: Involved in a Marine Casualty · activity 1833765
28 September 2001Routine · role: Involved in a Marine Casualty · activity 103808
22 July 2005Routine · role: Involved in a Marine Casualty · activity 2474055
23 June 2008Routine · role: Involved in a Marine Casualty · activity 3252335
22 August 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 3831757
17 October 2010Routine · role: Involved in a Marine Casualty · activity 3884964
28 September 2015Routine · role: Involved in a Marine Casualty · activity 5730824
18 January 2018Routine · role: Involved in a Marine Casualty · activity 6339349
12 June 2018Routine · role: Involved in a Marine Casualty · activity 6448060
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.