MAURY USCG vessel records
← All vessels

AUTOPRESTIGE

AUTOPRESTIGE is a freight ship. The Coast Guard has recorded 2 inspections in 2026, along with 3 deficiencies and 1 operational control.

Records in 2026. Most recent: inspection, 18 April 2026.

Built
Not recorded
Last inspected
18 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9190157
1898789
Flag
PORTUGAL
Maury page id
psix-1898789

Inspections, by type

…with no type recorded1
Years with a record 1 calendar year (2026)
The 2 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it11596 - Convention (Subpart B), Gross Ton
3837 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 2

18 April 2026 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8352050
17 February 2026 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8311327

Deficiency record · 3

14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 17 February 2026 Resolved
Every ship of 100 gross tons and above... shall carry a garbage management plan which the crew shall follow. PSCO observed storage of garbage in steering gear compartment. MARPOL V, Reg. 10.2 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2026
Resolved 6 March 2026
Resolution: Class report attesting repairs submitted
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 17 February 2026 Resolved
The machinery... associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so instlled and protected as to reduce to a minimum any danger to persons on board. PSCO observed 04 soft patches on the high expansion foam pipe on deck 6 and 01 soft patch on the fire main located on the starboard side, 1st bridge deck. 74SOLAS(04) II-1/26.1 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2026
Resolved 6 March 2026
Resolution: Class report attesting repairs submitted
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 17 February 2026 Resolved
... If there is valid International Load Line Certificate (1966) on board the ship, such control shall be limited to the purpose of determining that: the position of the Load Line of the ship corresponds with the certificate. PSCO observed the Triopical and Fresh Water lines were not matching the certificate. ICLL 66, Article 21(1)(b) 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2026
Resolved 6 March 2026
Resolution: Class report attesting repairs submitted

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.