MAURY USCG vessel records
← All vessels

DELOS C

DELOS C is a 2025 tank ship. The Coast Guard has recorded 2 inspections in 2026, along with 1 deficiency.

Records in 2026. Most recent: inspection, 25 March 2026.

Built
2025
Last inspected
25 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 March 2026
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1058341
1899495
Flag
LIBERIA
Maury page id
psix-1899495

Documentation record

Tonnage as PSIX records it49996 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

25 March 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8331995
7 February 2026 PSC A · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8304715

Deficiency record · 1

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 7 February 2026 Resolved
THE GAS DETECTION EQUIPMENT SHALL BE DESIGNED TO SAMPLE AND ANALYZE FROM EACH SAMPLING LINE OF EACH PROTECTED SPACE, SEQUENTIALLY AT INTERVALS NOT EXCEEDING 30 MINS. THE CREW WAS UNABLE TO ENSURE OPERATIONAL CAPABILITY OF FIXED GAS DETECTION EQUIPMENT IN THE CCR. 74 SOLAS (20) II-2/4.5.7.3.1 FSS CODE 16.2.2.3.1 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2026
Resolution: Corrected prior to departing the vessel.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.