Documentation record
Registered dimensions (L × B × D)38.0 ft × 15.9 ft × 3.7 ft
Registered tonnagegross 21 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCECIL TUTEN · WILLISTON NC, UNITED STATES · built 1980
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDAVIS, NC
Endorsements, as the file codes themcw_un, fi
DocumentationOn Deposit · issued 2 April 2019
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 12 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 12
19 February 2020
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6911873
11 June 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6698588
4 June 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6725498
6 May 2019
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6678148
12 June 2018
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6428279
22 January 2018
Administrative Inspection · In-Service Inspection · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6339360
23 October 2017
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6293461
5 July 2017
Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6200219
28 March 2017
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6106323
7 March 2017
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6100738
25 January 2017
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6076813
2 June 2016
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5894922
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 10 July 2019
Resolved
#1 frame portside LAZ/under car deck has missing nut marked.
Action required: 705 - Other - as specified
Due 10 July 2019
Resolved 10 July 2019
Resolution: Nut installed.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 10 July 2019
Resolved
vent covers for engine room not able to properly close due to missing hardware.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2019
Resolved 10 July 2019
Resolution: Fire dampners were closed and opened. SAT
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 July 2019
Resolved
Laz bilge alarm not working properly (no sound/visual)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2019
Resolution: Bilge alarms working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 July 2019
Resolved
Provide plan to ensure lifefloat is float free to MI.
Action required: 705 - Other - as specified
Due 16 July 2019
Resolved 10 July 2019
Resolution: Life Floats are made float free.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2019
Resolved
Deteriorated Life jackets 1 child, 1 child PFD retro needed, 5 adult PFD retro needed.
Limited to 1 child and 25 adult passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 10 July 2019
Resolution: All SAT, new life jacket onboard with proper retro on others.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 June 2019
Resolved
First aid kit not CG approved. 46CFR160.041
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 10 July 2019
Resolution: New first aid kit onboard
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 June 2019
Resolved
Cracked forward handrail port side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 10 July 2019
Resolution: forward hand rail welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2019
Resolved
Corrosion on battery
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2019
Resolution: Battery cleaned and lubed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 June 2019
Resolved
Clean debris out of bilges, bilge suction strainers and life jacket storage boxes.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Bilges cleaned
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 11 June 2019
Resolved
Cargo net wasted and not properly installed. Fittings wasted, netting holed, securing line wasted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2019
Resolution: New wire added in place of line. tested sat
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 June 2019
Resolved
Conduct underway drills and operational test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2019
Resolution: Operational test and drills sat
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 June 2019
Resolved
Make proper reairs to port side shell fwd engine room bulkhead to from 4 sheer. Determine repairs and submit repair plan to CG for approval / review.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2019
Resolution: Repairs to damage SAT
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 June 2019
Resolved
Provide 2692 and statement for unreported damage to port side hull.
Action required: 705 - Other - as specified
Due 16 June 2019
Resolved 10 July 2019
Resolution: 2692 provided at earlier date.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 June 2019
Resolved
Bilge hose loose lower cabin
Action required: 705 - Other - as specified
Due 10 July 2019
Resolved 10 July 2019
Resolution: Hose found to be tight.
Construction/Loadline › Hull › Stiffener
Issued 1 September 2017
Resolved
Identified rott in the Stern Post. Stern Post shall be renewed as original.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 6 May 2019
Resolution: Renewed
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 1 September 2017
Resolved
Identified holes on the Port and Starboard Engine Room canvas ventilation covers. Replace or make repairs to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2017
Resolved 23 October 2017
Resolution: New covers were installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 September 2017
Resolved
Forward compartment was missing overhead lighting heat shield.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 23 October 2017
Resolution: Light removed
Construction/Loadline › Hull › Transverse Frame
Issued 1 September 2017
Resolved
Identified rott in the Port Frame #1 in the Engine Room. Renew or make repairs to the frame to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 6 May 2019
Resolution: Renewed
Construction/Loadline › Hull › Hull Plating
Issued 1 September 2017
Resolved
Refasten along garboards with 3 1/2" monel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 6 May 2019
Resolution: Refastened
Stability › Weathertight Integrity › General
Issued 1 September 2017
Resolved
Replace Pilot House window gaskets on port, stbd and middle windows.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 23 October 2017
Resolution: All three fwd windows gsk replaced.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 28 March 2017
Resolved
Rescue Plat form 1.5 foot below water line when installed for MOB. shorten rescue plat form required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 23 October 2017
Resolution: This was completed back in April and tested SAT. Plate form was shorten to water line from port bow.