MAURY USCG vessel records Sign in
← All vessels

KATHRYN T

KATHRYN T is a 1980 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1990, most recently in February 2020, along with 92 deficiencies and 1 casualty investigation in 2019.

Records from 1990 to 2020. Most recent: inspection, 19 February 2020.

Built
1980
Last inspected
19 February 2020
Documentation
On Deposit · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC7339
190135
Flag
UNITED STATES
367069850
Maury page id
psix-190135

Inspections, by type

…with no type recorded3
Years with a record 28 calendar years (1990–2020)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.0 ft × 15.9 ft × 3.7 ft
Registered tonnagegross 21 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCECIL TUTEN · WILLISTON NC, UNITED STATES · built 1980
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDAVIS, NC
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationOn Deposit · issued 2 April 2019
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ6617MMSI 367069850 · active · compulsorily equipped · granted 13 July 2017, expires 13 July 2027
WDC7339MMSI 367069850 · expired · compulsorily equipped · granted 1 October 2005, cancelled 5 December 2015
WAO9737MMSI not assigned · expired · compulsorily equipped · granted 7 August 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 57

19 February 2020 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6911873
11 June 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6698588
4 June 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6725498
6 May 2019 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6678148
12 June 2018 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6428279
22 January 2018 Administrative Inspection · In-Service Inspection · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6339360
23 October 2017 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6293461
5 July 2017 Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6200219
28 March 2017 COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6106323
7 March 2017 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6100738
25 January 2017 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6076813
2 June 2016 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5894922
20 October 2014 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5008735
6 June 2014 Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4880903
12 June 2012 Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4341955
1 December 2011 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4199622
25 July 2011 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4093825
17 July 2011 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4084157
16 February 2011 Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3945454
22 April 2009 Annual Inspection · DAPI Audit
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3453610
11 February 2009 Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3416019
21 January 2009 Plan Review "T" Boat
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3607587
21 August 2008 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 3311044
27 March 2008 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3200215
31 January 2007 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2867308
23 May 2006 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2658906
7 July 2005 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2425577
6 May 2005 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2350869
11 January 2005 Hull Examination · Internal Structural Exam
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2272840
26 May 2004 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2080737
30 April 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1788202
10 February 2003 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1742326
10 April 2002 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1602836
9 May 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1425124
7 March 2001 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1422001
28 March 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1369593
10 February 2000 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1445568
14 April 1999 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1440122
11 March 1999 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1450245
17 February 1999 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1395112
2 September 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1398947
16 September 1997 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1108526
8 September 1997 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1095768
19 September 1996 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 951002
1 November 1995 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1192335
27 September 1995 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1190970
24 September 1995 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 220879
2 September 1995 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1371157
12 September 1994 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1179066
27 January 1994 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1162760
14 September 1993 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1145010
20 October 1992 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 934950
15 September 1992 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1262259
18 May 1992 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 956871
1 April 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1270594
27 August 1991 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1249794
18 September 1990 Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1240135

Deficiency record · 92

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 10 July 2019 Resolved
#1 frame portside LAZ/under car deck has missing nut marked.
Action required: 705 - Other - as specified
Due 10 July 2019
Resolved 10 July 2019
Resolution: Nut installed.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 10 July 2019 Resolved
vent covers for engine room not able to properly close due to missing hardware.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2019
Resolved 10 July 2019
Resolution: Fire dampners were closed and opened. SAT
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 July 2019 Resolved
Laz bilge alarm not working properly (no sound/visual)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2019
Resolution: Bilge alarms working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 July 2019 Resolved
Provide plan to ensure lifefloat is float free to MI.
Action required: 705 - Other - as specified
Due 16 July 2019
Resolved 10 July 2019
Resolution: Life Floats are made float free.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2019 Resolved
Deteriorated Life jackets 1 child, 1 child PFD retro needed, 5 adult PFD retro needed. Limited to 1 child and 25 adult passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 10 July 2019
Resolution: All SAT, new life jacket onboard with proper retro on others.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 June 2019 Resolved
First aid kit not CG approved. 46CFR160.041
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 10 July 2019
Resolution: New first aid kit onboard
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 June 2019 Resolved
Cracked forward handrail port side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 10 July 2019
Resolution: forward hand rail welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2019 Resolved
Corrosion on battery
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2019
Resolution: Battery cleaned and lubed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 June 2019 Resolved
Clean debris out of bilges, bilge suction strainers and life jacket storage boxes.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2019
Resolution: Bilges cleaned
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 11 June 2019 Resolved
Cargo net wasted and not properly installed. Fittings wasted, netting holed, securing line wasted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2019
Resolution: New wire added in place of line. tested sat
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 June 2019 Resolved
Conduct underway drills and operational test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2019
Resolution: Operational test and drills sat
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 June 2019 Resolved
Make proper reairs to port side shell fwd engine room bulkhead to from 4 sheer. Determine repairs and submit repair plan to CG for approval / review.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2019
Resolution: Repairs to damage SAT
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 June 2019 Resolved
Provide 2692 and statement for unreported damage to port side hull.
Action required: 705 - Other - as specified
Due 16 June 2019
Resolved 10 July 2019
Resolution: 2692 provided at earlier date.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 June 2019 Resolved
Bilge hose loose lower cabin
Action required: 705 - Other - as specified
Due 10 July 2019
Resolved 10 July 2019
Resolution: Hose found to be tight.
Construction/Loadline › Hull › Stiffener
Issued 1 September 2017 Resolved
Identified rott in the Stern Post. Stern Post shall be renewed as original.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 6 May 2019
Resolution: Renewed
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 1 September 2017 Resolved
Identified holes on the Port and Starboard Engine Room canvas ventilation covers. Replace or make repairs to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2017
Resolved 23 October 2017
Resolution: New covers were installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 September 2017 Resolved
Forward compartment was missing overhead lighting heat shield.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 23 October 2017
Resolution: Light removed
Construction/Loadline › Hull › Transverse Frame
Issued 1 September 2017 Resolved
Identified rott in the Port Frame #1 in the Engine Room. Renew or make repairs to the frame to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 6 May 2019
Resolution: Renewed
Construction/Loadline › Hull › Hull Plating
Issued 1 September 2017 Resolved
Refasten along garboards with 3 1/2" monel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 6 May 2019
Resolution: Refastened
Stability › Weathertight Integrity › General
Issued 1 September 2017 Resolved
Replace Pilot House window gaskets on port, stbd and middle windows.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 23 October 2017
Resolution: All three fwd windows gsk replaced.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 28 March 2017 Resolved
Rescue Plat form 1.5 foot below water line when installed for MOB. shorten rescue plat form required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 23 October 2017
Resolution: This was completed back in April and tested SAT. Plate form was shorten to water line from port bow.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 July 2014 Resolved
Renew batteries IWO ring buoy waterlight
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 27 August 2014
Fire Fighting › Fire Hoses › Condition
Issued 8 July 2014 Resolved
Renew fire hose due to wear (wrapped in tape and leaking)
Due 18 July 2014
Resolved 27 August 2014
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 8 July 2014 Resolved
Service fire boy (manual pull not connected)
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 27 August 2014
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 8 July 2014 Resolved
Renew rusted out portable fire extinguisher IWO stbd wheelhouse
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 27 August 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 July 2014 Resolved
Remove dead end wiring IWO wheelhouse
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 27 August 2014
Construction/Loadline › Hull › Side Shell
Issued 12 June 2014 Resolved
Crop and renew side shell plating outboard of port fwd void #1. Side shell plated outboard of the frame.
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 17 June 2014
Resolution: Side shell planking was renewed with juniper wood to the satisfaction of the marine inspector.
Construction/Loadline › Hull › Side Shell
Issued 12 June 2014 Resolved
Sand and fill cavity IWO stbd side shell planking at stem and midbody
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 17 June 2014
Resolution: Cavities in the side shell planking were sanded and filled to the satisfaction of the marine inspector.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 12 June 2014 Resolved
Renew lubricated bearing IWO propulsion shaft.
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 17 June 2014
Resolution: Cutlass bearing was renewed IWO propulsion shaft.
Construction/Loadline › Hull › Stiffener
Issued 12 June 2014 Resolved
Provide hardware IWO forepeak frame #2 (upper fastener port side where the deck ties in with the framing)
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 8 July 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 June 2014 Resolved
Remove dead end wiring IWO void #1 fwd of engine space
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 8 July 2014
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 12 June 2014 Resolved
Provide guards to rotating machinery (belt guards to main diesel engine)
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 8 July 2014
Engineering › Lubricating Oil Service System › Hose
Issued 12 June 2014 Resolved
Renew lube oil guage line (from main diesel engine to bridge console gauge)
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 8 July 2014
Engineering › Fuel Oil Service System › Valve
Issued 12 June 2014 Resolved
Properly secure free hanging fuel valves port outboard of main engine
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 8 July 2014
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 June 2014 Resolved
Properly seal bulkhead penetrations IWO port side "watertight" aft bulkhead in engine space
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 8 July 2014
Engineering › Bilge Water Management System › Hose
Issued 12 June 2014 Resolved
Provide double clamps IWO bilge discharge lines throughout vessel
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 8 July 2014
Fire Fighting › Fire Pumps › Suction Valve
Issued 12 June 2014 Resolved
Remove fire pump gate valve for inspection. Correct kink in hose.
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 8 July 2014
Engineering › Bilge Water Management System › Pump
Issued 12 June 2014 Resolved
Remove 2 electric bilge pumps from lazarette (currently disconnected)
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 8 July 2014
Engineering › Lubricating Oil Service System › Hose
Issued 12 June 2014 Resolved
Renew wasted reduction gear lube oil hose
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 8 July 2014
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 12 June 2014 Resolved
Complete exhaust insullation wrap IWO turbo charger
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 8 July 2014
Construction/Loadline › Structures › Manhole
Issued 12 June 2014 Resolved
Repair broken glass to pilot house window port side
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 8 July 2014
Construction/Loadline › Hull › Keel Plate
Issued 12 June 2014 Resolved
Renew fasteners for stainless steel tunnel guard
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 8 July 2014
Engineering › Steering Gear System › Rudder
Issued 12 June 2014 Resolved
Repair rudder stock bottom wear plate
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 17 June 2014
Lifesaving › Lifefloat › Lifeline
Issued 27 March 2008 Resolved
Replace grab lines on life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2008
Resolved 22 April 2009
Resolution: Renewed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 March 2008 Resolved
Replace lifeline around lifering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2008
Resolved 22 April 2009
Resolution: Renewed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 March 2008 Resolved
Replace retro-reflective tape on life ring.
Action required: 705 - Other - as specified
Due 27 April 2008
Resolved 22 April 2009
Resolution: Renewed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 March 2008 Resolved
Separate adult life jackets from child jackets and properly label storage areas.
Action required: 705 - Other - as specified
Due 27 April 2008
Resolved 22 April 2009
Resolution: Corrected.
Lifesaving › Hand Flares › Storage
Issued 27 March 2008 Resolved
Provide waterproof container for flares and properly mark.
Action required: 705 - Other - as specified
Due 27 April 2008
Resolved 22 April 2009
Resolution: Corected.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 March 2008 Resolved
Provide current copy of CG Light List
Action required: 705 - Other - as specified
Due 27 April 2008
Resolved 22 April 2009
Resolution: Provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 March 2008 Resolved
Provide current copy of US Coast Pilot
Action required: 705 - Other - as specified
Due 27 April 2008
Resolved 22 April 2009
Resolution: Provided.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 March 2008 Resolved
Provide proper, stable staging area for rescue ladder
Action required: 705 - Other - as specified
Due 27 April 2008
Resolved 22 April 2009
Resolution: Corrected.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 May 2006 Resolved
Install a high water alarm sensor in the shaft compartment
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 23 June 2006
Fire Fighting › Fire Pumps › Impeller
Issued 23 May 2006 Resolved
Replace impeller for fire pump: Temperary fix - install three 2.5 gallon buckets with line. Label buckets "Fire Bucket" and install onboard until repairs are made to fire pump.
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 23 June 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 April 2003 Resolved
ANCHOR [name withheld].
Action required: 705 - Other - as specified
Resolved 30 April 2003
Resolution: REPLACED FAULTY BULB.
Fire Fighting
Issued 2 September 1998 Resolved
PROVIDE FIXED FIRE EXTINGUISHING AND DETECTING SYSTEM FOR ENGINE ROOM AS REQUIRED BY 46 CFR 181.400.
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Construction/Loadline
Issued 2 September 1998 Resolved
PROVIDE BILGE HIGH LEVEL ALARMS AS REQUIRED BY 46 CFR 182.530.
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Construction/Loadline
Issued 8 September 1997 Resolved
REMOVE UPPER BUTT BLOCK IN WAY OF FRAME BAY 8 FROM STERN ON STBD SIDE, FOR FURTHER EVALUATION.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE FRAMES 10 & 11 FROM STERN ON STBD SIDE.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
Kill and fill worm damage at after end of keel.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
KILL AND FILL WORM DAMAGE LOCATED ON PORT SIDE IN WAY OF GARBOARD APPROX 15' FROM BOW.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REMOVE BLOCK LOCATED ON PORT SIDE, FWD OF KEEL COOLER FOR FURTHER ASSESSMENT.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE STRIP PLANKING LOCATED ON STBD SIDE APPROX 10' & 15' FROM STERN, WHERE HOLED.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE DECK PLANK LOCATED ON STBD SIDE - 6TH DECK PLANK AFT OF FUELTANK.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE DECK PLANK ON STBD SIDE 9TH PLANK FROM OUTER HULL, AFT OF REQT #17.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE DECK BEAM LOCATED ON PORT SIDE, 4TH BEAM AFT OF FUEL TANK.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE 1ST & 3RD STERN FRAME FROM PORT SIDE, WHERE WASTED.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE SKID ALONGSIDE SHAFT, AFT OF ENGINE BED.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE FRAME HEAD LOCATED AT 13TH FRAME FROM STERM, PORT SIDE.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE STRIP PLANK LOCATED ON STBD SIDE, MIDSHIP, WHERE HOLED.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE STRIP PLANKS ON STBD SIDE FWD OF KELL COOLER, WHERE HOLED.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPLACE PLANK ON STBD SIDE, FWD, APPROX 4' FROM STEM AS DISCUSSED.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE FLOOR FRAME IN WAY OF 9TH FRAME FROM STERN ON STBD SIDE.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE FRAME HEAD, 6TH FRAME FROM STERN ON STBD SIDE AND ASSOCIATEDFLOOR FRAME.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE 8TH FRAME FROM STERN ON STBD SIDE AND ASSOCIATED PLANK WHEREWASTED.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE PLANKING ON MAIN DECK LOCATED ON PORT SIDE, AFT, WHERE DRY ROTTED.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE DECK PLANKING, FWD OF PILOT HSE, WHERE DRY ROTTED.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE FLOOR FRAME LOCATED AT 3RD & 5TH FRAME FROM STERN, STBD SIDE, WHERE WASTED.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 8 September 1997 Resolved
REPAIR/REPLACE FRAME HEAD, 2ND FRAME FROM STERN ON PORT SIDE, WHERE WASTED.
Condition: Unknown
Due 8 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 19 September 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REFASTEN STBD SIDE WAIST AREA WHERE WORKING.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Construction/Loadline
Issued 19 September 1996 Resolved
PRIOR TO VESSEL OPERATING, REMOVE EXCESS OIL FROM BILGE AND DEMONSTRATE PROPER OPERATION OF FIXED BILGE SYSTEM.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Construction/Loadline
Issued 19 September 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPAIR/REPLACE STERN PLANK IN WAY OF STBD SIDE STERN POST.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Documentation
Issued 19 September 1996 Resolved
PROVIDE AND POST STABILITY LETTER NO LATER THAN 11 OCTOBER 1996.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Lifesaving
Issued 27 September 1995 Resolved
INSTALL GUARD ON M/E DRIVEN FIRE PUMP NLT THAN 21OCT95.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Lifesaving
Issued 27 September 1995 Resolved
PRIOR TO OPERATING W/PASSENGERS, PROVIDE APPROVED WEAK-LINK FOR_x001C_ (15 PERSON) LIFEFLOAT.
Condition: Unknown
Due 27 September 1995
Resolved 29 September 1995
Lifesaving
Issued 27 September 1995 Resolved
PRIOR TO OPERATING W/PASSENGERS, LABEL & PROPERLY SEPARATE CHILD/ADULT LIFEJACKET STOWAGE.
Condition: Unknown
Due 27 September 1995
Resolved 29 September 1995
Engineering
Issued 15 September 1992 Resolved
REPLACE FLEXIBLE FUEL HOSE TO MAIN DIESEL ENGINE WITH APPROVED HOSE AND PROPER FITTINGS.
Condition: Unknown
Due 15 September 1992
Resolved 15 September 1992
Fire Fighting
Issued 18 September 1990 Resolved
PROVIDE A HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990
Engineering
Issued 18 September 1990 Resolved
INSTALL PROPER VENT LINES FOR BOTH FUEL TANKS WITH FLAME SCREENS.
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990
Engineering
Issued 18 September 1990 Resolved
INSTALL A PROPER BILGE OVERBOARD CONNECTION WITH VALVE.
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990
Engineering
Issued 18 September 1990 Resolved
INSTALL REMOTE FUEL SHUTOFF VALVES FOR BOTH FUEL TANKS.
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990
Documentation
Issued 18 September 1990 Resolved
PROVIDE FCC RADIOTELEPHONY CERTIFICATE
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990
Lifesaving
Issued 18 September 1990 Resolved
PROVIDE 10 ADDITIONAL ADULT PFD'S, VESSEL CANNOT CARRY MORE THAN 20 TOTAL PERSONS UNTIL PROVIDED.
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990

Casualty record · 1

4 June 2019Routine · role: Involved in a Marine Casualty · activity 6725498
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.