← All vessels
CMA CGM KAILAS
CMA CGM KAILAS is a freight ship. The Coast Guard has recorded 2 inspections in 2026, along with 3 deficiencies.
Records in 2026. Most recent: inspection, 4 May 2026.
- Built
- Not recorded
- Last inspected
- 4 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9339545 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3ECM4
1901986
Flag
PANAMA
—
Maury page id
psix-1901986
Inspections, by type
The 2 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it21971 - Convention (Subpart B), Gross Ton
24161 - Dead Weight, Ton
24161 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 2
4 May 2026
PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8361240
3 May 2026
COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8360837
Deficiency record · 3
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 May 2026
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed small accumulation of oil below the number 2 generator.
74 SOLAS (09) II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 May 2026
Resolved
Fire protection systems and firefighting systems and appliances shall be properly tested and inspected. PSCO observed a failed test of the flame detctor inside the fuel oil purifier space.
74 SOLAS (09) II-2/14.1.2
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 May 2026
Resolved
Fire protection systems and firefighting systems and appliances shall be maintained ready for use. PSCO observed fire extinguisher with inadequate pressure inside the engineer's workshop.
74 SOLAS (09) II-2/14.1.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.