Records from 1989 to 2004. Most recent: inspection, 29 April 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
29 April 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2055568
25 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884689
6 April 1998
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471492
9 May 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414795
25 April 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1357550
23 May 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 669639
13 May 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219888
28 March 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382926
8 February 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212639
20 April 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439498
2 February 1993
Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385025
22 May 1991
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 919848
8 January 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901134
7 December 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 915080
4 December 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904341
20 July 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 918246
12 July 1989
Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1201859
Construction/Loadline
Issued 28 March 1995
Resolved
REPAINT VESSEL DRAFT MARKS.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Engineering
Issued 28 March 1995
Resolved
PROVIDE MACHINERY GUARDS FOR BOTH MAIN ENGINE WATER PUMP PULLEYS.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Documentation
Issued 28 March 1995
Resolved
PROVIDE AN APPROVED OPERATION MANUAL TO MSO MORGAN CITY.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Accommodation/Occupational Safety
Issued 12 July 1989
Resolved
PROVIDE COVERS FOR VENTS IAW 46 CFR 182.20-45.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Navigation
Issued 12 July 1989
Resolved
NAVIGATION LIGHTS ARE TO BE IAW 33 CFR PART 81 AS APPLICABLE. *SEE COMMENTS BELOW.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Lifesaving
Issued 12 July 1989
Resolved
LIFEFLOATS TO BE MARKED IAW 46 CFR 180.15-1(A), LIFEFLOATS ARE TO BE STOWED IAW 46 CFR 180.20.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Lifesaving
Issued 12 July 1989
Resolved
VESSEL IS TO BE PROVIDED WITH DISTRESS SIGNALS IAW 46 CFR 180.35.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989
Resolved
SUBMIT STABILITY CALCULATIONS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, DC. IAW 46 CFR 91.55.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989
Resolved
OBTAIN AND PLACE ON BOARD THE VESSEL A CURRENT CERTIFICATE OF DOCUMENTATIONIAW 46 CFR 67.23-1(A).
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989
Resolved
SUBMIT THE FOLLOWING PLANS TO THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, DC FOR REVIEW & APPROVAL: IN & OUT BOARD PROFILES, LEG & LEG TOWER STRUCTURAL DRAWINGS, HYDRAULIC SYSTEM INCLUDING ALARMS. IAW NVIC 8-81 CHANGE 1.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Deck/Cargo
Issued 12 July 1989
Resolved
PROVIDE ONE (1) ANCHOR WITH HOLDING POWER OF AT LEAST 2300 LBS AND AN ANCHOR LINE 270 FT. IN LENGTH WHICH IS AT LEAST 3.25" IN CIRCUMFERENCE AND BE MANILA OR ITS EQUIVALENCE. IAW 46 CFR 184.10.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Engineering
Issued 12 July 1989
Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF A POWER BILGE PUMPING SYSTEM. IAW 46 CFR 182.25.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Fire Fighting
Issued 12 July 1989
Resolved
PROVIDE FIRE PUMP IAW 46 CFR 181.10.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Fire Fighting
Issued 12 July 1989
Resolved
FIRE EXTINGUISHERS SHALL BE SERVICED IAW 46 CFR 176.25-25.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Engineering
Issued 12 July 1989
Resolved
MAIN EXHAUST SHALL BE INSULATED IAW 46 CFR 182.15-20.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989
Resolved
GUARDS ARE TO BE INSTALLED IN WAY OF ALL ROTATING MACHINERY. IAW 46 CFR 177.35-15.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989
Resolved
INSTALL REMOTE SHUT OFFS FOR FUEL OIL TANKS IAW 46 CFR 182.20-40 (B)(3).
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989
Resolved
FUEL OIL TANK VENTS SHALL BE IAW 46 CFR 182.20-35.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989
Resolved
FUEL OIL TANK FILLS SHALL BE IAW 46 CFR 182.20-30.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989
Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF A U.S. COAST GUARD APPROVED MARINE SANITATION DEVICE. IAW 33 CFR PART 159.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989
Resolved
EMERGENCY ESCAPES ARE TO MARKED IAW 46 CFR 185.30-15.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Engineering
Issued 12 July 1989
Resolved
INSTALL AND PROVE PROPER OPERATION OF JACKING SYSTEM FAILURE ALARMS IAW NVIC 8-81 CHANGE 1.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989
Resolved
PROVIDE APPROVED PLANS AS PER ITEM 17 AND APPROVED OPERATING MANUAL AS PER ITEM 2.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989
Resolved
SUBMIT OPERATION MANUAL FOR REVIEW AND APPROVAL TO THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON DC. IAW NVIC 8-81 CHANGE 1.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Engineering
Issued 12 July 1989
Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF A DEADMAN TYPE JACKING CONTROL SYSTEM. IAW NVIC 8-81 CHANGE 1.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Electrical
Issued 12 July 1989
Resolved
BATTERY BOXES & BATTERIES SHALL CONFORM WITH 46 CFR 183.05-20.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989