MAURY USCG vessel records Sign in
← All vessels

SUPERIOR STANDARD

SUPERIOR STANDARD is a 1980 offshore supply vessel. The Coast Guard has recorded 17 inspections since 1989, most recently in April 2004, along with 26 deficiencies.

Records from 1989 to 2004. Most recent: inspection, 29 April 2004.

Built
1980
Last inspected
29 April 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCP4379
190809
Flag
UNITED STATES
366817940 (licence lapsed)
Maury page id
psix-190809

Inspections, by type

…with no type recorded3
Years with a record 11 calendar years (1989–2004)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDA5236MMSI 366817940 · cancelled · compulsorily equipped · granted 6 July 2001, cancelled 31 July 2006
WCP4379MMSI not assigned · expired · voluntarily equipped · granted 1 February 1999, cancelled 19 February 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 17

29 April 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2055568
25 June 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884689
6 April 1998 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471492
9 May 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414795
25 April 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1357550
23 May 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 669639
13 May 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219888
28 March 1995 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382926
8 February 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212639
20 April 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439498
2 February 1993 Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385025
22 May 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 919848
8 January 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901134
7 December 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 915080
4 December 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904341
20 July 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 918246
12 July 1989 Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1201859

Deficiency record · 26

Construction/Loadline
Issued 28 March 1995 Resolved
REPAINT VESSEL DRAFT MARKS.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Engineering
Issued 28 March 1995 Resolved
PROVIDE MACHINERY GUARDS FOR BOTH MAIN ENGINE WATER PUMP PULLEYS.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Documentation
Issued 28 March 1995 Resolved
PROVIDE AN APPROVED OPERATION MANUAL TO MSO MORGAN CITY.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Accommodation/Occupational Safety
Issued 12 July 1989 Resolved
PROVIDE COVERS FOR VENTS IAW 46 CFR 182.20-45.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Navigation
Issued 12 July 1989 Resolved
NAVIGATION LIGHTS ARE TO BE IAW 33 CFR PART 81 AS APPLICABLE. *SEE COMMENTS BELOW.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Lifesaving
Issued 12 July 1989 Resolved
LIFEFLOATS TO BE MARKED IAW 46 CFR 180.15-1(A), LIFEFLOATS ARE TO BE STOWED IAW 46 CFR 180.20.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Lifesaving
Issued 12 July 1989 Resolved
VESSEL IS TO BE PROVIDED WITH DISTRESS SIGNALS IAW 46 CFR 180.35.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989 Resolved
SUBMIT STABILITY CALCULATIONS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, DC. IAW 46 CFR 91.55.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989 Resolved
OBTAIN AND PLACE ON BOARD THE VESSEL A CURRENT CERTIFICATE OF DOCUMENTATIONIAW 46 CFR 67.23-1(A).
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989 Resolved
SUBMIT THE FOLLOWING PLANS TO THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, DC FOR REVIEW & APPROVAL: IN & OUT BOARD PROFILES, LEG & LEG TOWER STRUCTURAL DRAWINGS, HYDRAULIC SYSTEM INCLUDING ALARMS. IAW NVIC 8-81 CHANGE 1.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Deck/Cargo
Issued 12 July 1989 Resolved
PROVIDE ONE (1) ANCHOR WITH HOLDING POWER OF AT LEAST 2300 LBS AND AN ANCHOR LINE 270 FT. IN LENGTH WHICH IS AT LEAST 3.25" IN CIRCUMFERENCE AND BE MANILA OR ITS EQUIVALENCE. IAW 46 CFR 184.10.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Engineering
Issued 12 July 1989 Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF A POWER BILGE PUMPING SYSTEM. IAW 46 CFR 182.25.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Fire Fighting
Issued 12 July 1989 Resolved
PROVIDE FIRE PUMP IAW 46 CFR 181.10.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Fire Fighting
Issued 12 July 1989 Resolved
FIRE EXTINGUISHERS SHALL BE SERVICED IAW 46 CFR 176.25-25.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Engineering
Issued 12 July 1989 Resolved
MAIN EXHAUST SHALL BE INSULATED IAW 46 CFR 182.15-20.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989 Resolved
GUARDS ARE TO BE INSTALLED IN WAY OF ALL ROTATING MACHINERY. IAW 46 CFR 177.35-15.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989 Resolved
INSTALL REMOTE SHUT OFFS FOR FUEL OIL TANKS IAW 46 CFR 182.20-40 (B)(3).
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989 Resolved
FUEL OIL TANK VENTS SHALL BE IAW 46 CFR 182.20-35.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989 Resolved
FUEL OIL TANK FILLS SHALL BE IAW 46 CFR 182.20-30.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989 Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF A U.S. COAST GUARD APPROVED MARINE SANITATION DEVICE. IAW 33 CFR PART 159.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989 Resolved
EMERGENCY ESCAPES ARE TO MARKED IAW 46 CFR 185.30-15.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Engineering
Issued 12 July 1989 Resolved
INSTALL AND PROVE PROPER OPERATION OF JACKING SYSTEM FAILURE ALARMS IAW NVIC 8-81 CHANGE 1.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989 Resolved
PROVIDE APPROVED PLANS AS PER ITEM 17 AND APPROVED OPERATING MANUAL AS PER ITEM 2.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989 Resolved
SUBMIT OPERATION MANUAL FOR REVIEW AND APPROVAL TO THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON DC. IAW NVIC 8-81 CHANGE 1.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Engineering
Issued 12 July 1989 Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF A DEADMAN TYPE JACKING CONTROL SYSTEM. IAW NVIC 8-81 CHANGE 1.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Electrical
Issued 12 July 1989 Resolved
BATTERY BOXES & BATTERIES SHALL CONFORM WITH 46 CFR 183.05-20.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.