Records from 1986 to 2024. Most recent: inspection, 14 February 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 46
14 February 2024
Type not recorded
No type recorded · USCGC IBIS (WPB 87338) · USCG Southeast District (CGD-SE) · Activity 7870851
13 April 2017
Type not recorded
No type recorded · USCGC SAWFISH (WPB 87357) · USCG Southeast District (CGD-SE) · Activity 6141475
18 April 2008
DAPI Audit
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3186954
16 November 2007
Uninspected Passenger Vessel · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3100845
25 October 2007
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3082237
8 February 2007
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2869232
18 October 2006
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2807312
29 March 2006
Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2611762
20 July 2005
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2431045
18 October 2004
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2222937
12 April 2004
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2043435
17 November 2003
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1949821
7 November 2003
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1945060
6 October 2003
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1922367
7 October 2002
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1687366
13 May 2002
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1615975
10 October 2001
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1423650
25 July 2000
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1410369
23 May 2000
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1456832
2 October 1999
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1349178
11 August 1999
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1112501
13 July 1999
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1445490
14 July 1998
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 794059
30 June 1998
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 792688
16 April 1998
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1414980
15 May 1997
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1103381
20 June 1996
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1077662
4 April 1996
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1078422
15 May 1995
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 911199
27 March 1995
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 828625
15 April 1994
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1169041
14 April 1994
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1169046
25 February 1994
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1163957
23 April 1993
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1148599
30 March 1992
Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 958904
27 January 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 949890
25 March 1991
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1306096
31 January 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 958905
16 March 1989
Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 895108
15 November 1988
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1205681
20 July 1988
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1339485
21 April 1988
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1037875
28 March 1988
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1298619
12 March 1987
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1329102
21 January 1987
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1329101
20 March 1986
Deficiency Check · Credit Drydock · Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 994121
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 February 2008
Resolved
While conducing DAPI Audit, inspectors determined there was not a company program in place.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 10 June 2008
Resolution: Company program is now in place.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 13 February 2008
Resolved
No drug testing background checks completed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 10 June 2008
Resolution: Educated employeer of requirements for future hires and verified ability to do so.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 13 February 2008
Resolved
No EAP information, Policy/Statement, or hotline number posted.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 10 June 2008
Resolution: EAP hotline and policy posted.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 13 February 2008
Resolved
Supervisors had not had any documented EAP training.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 10 June 2008
Resolution: EAP training provided to supervisors of the company.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 13 February 2008
Resolved
No documentation of MIS submission.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 10 June 2008
Resolution: Documentation available to verify submission of MIS Report.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 February 2008
Resolved
No list for covered employees.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 10 June 2008
Resolution: Documentation available for the covered employees.
Lifesaving › Hand Flares › Expired
Issued 16 November 2007
Resolved
PROVIDE VISUAL DISTRESS SIGNALS 3 DAY AND 3 NIGHT HANDHELD FLARES.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 December 2007
Engineering › Steering Gear System › Rudder Stock
Issued 16 November 2007
Resolved
EXCESSIVE WATER LEAKAGE IN WAY OF THE RUDDER PACKING GLAND.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 December 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 16 November 2007
Resolved
EXCESSIVE WATER LEAKAGE IN WAY OF THE ENGINE EXHAUST IN THE ENGINE ROOM.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 December 2007
Stability › Unintentional Flooding › General
Issued 16 November 2007
Resolved
EXCESSIVE WATER LEAKAGE THROUGHT THE KEEL BOLTS LOCATED IN THE VESSELS ENGINE COMPARTMENT.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 11 December 2007
Communications › Radio Communications › EPIRB
Issued 25 October 2007
Resolved
Provide current hydrostatic release for EPIRB. Vessel restricted to less then 3nm
Action required: 705 - Other - as specified
Resolved 11 December 2007
Lifesaving › Lifefloat › Markings
Issued 25 October 2007
Resolved
Stencil name on life float
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2007
Resolved 11 December 2007
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 25 October 2007
Resolved
Install retro tape on ring buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2007
Resolved 11 December 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 October 2007
Resolved
Provide first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2007
Communications › Visual Communication › Red Warning Signal
Issued 25 October 2007
Resolved
Provide 6 day flares
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 October 2007
Resolved
Stencil storage for life jackets and mount placards for life jackets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2007
Resolved 11 December 2007
Construction/Loadline › Hull › Keel
Issued 25 October 2007
Resolved
Repair keel bolt, water leaking in to the bilge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2007
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 25 October 2007
Resolved
Replace all aft mounting bolts on the port and stbd sides.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 25 October 2007
Resolved
Repair or replace the port and stbd exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2007
Engineering › Fuel Oil Service System › Valve
Issued 25 October 2007
Resolved
Repair or replace the fuel shut off valves
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2007
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 25 October 2007
Resolved
Excessive oil leaking from engine. Repair leaks and remove oil from engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2007
Engineering › Steering Gear System › Rudder Stock
Issued 25 October 2007
Resolved
Repack rudder post, post loose and is leaking excessively
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2007
Resolved 11 December 2007
Stability › Watertight Integrity › General
Issued 25 October 2007
Resolved
Remove wooden plug in the through hull fitting on the port side and proper repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 October 2007
Resolved
Provide bilge alarms and demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 25 October 2007
Resolved
Remove all dead end cables and old steering lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2007
Resolved 11 December 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 October 2007
Resolved
Repair the sagging step leading down into the fwd compartment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2007
Resolved 11 December 2007
Lifesaving › Lifefloat › Float-free Link
Issued 18 October 2006
Resolved
Life Float is not installed in a float free arrangement and the weak link is not properly attached to the vessel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2007
Resolved 26 April 2007
Resolution: Installed new life float in proper float free arrangement on top of forward cabin.
Lifesaving › Lifefloat › Serviceable
Issued 18 October 2006
Resolved
Life Float missing the net and platform is missing, paddles missing.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2007
Resolution: New life float installed.
Lifesaving › Lifefloat › Serviceable
Issued 18 October 2006
Resolved
Small tear in life float, and all pendants are imporperly stowed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 December 2006
Resolved 26 April 2007
Resolution: New life float installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 October 2006
Resolved
Lifering has approximately 20 feet of nylon line attached, needs 60 feet of floating line attached.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2007
Resolution: New 60 floating life line attached to life ring.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 October 2006
Resolved
Anchor light lens is cracked, renew lens.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 December 2006
Resolved 26 April 2007
Resolution: New ancor light lens installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 October 2006
Resolved
Deck light lens and bulb are shattered exposing the electrical socket, repair or remove light fixture.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 December 2006
Resolved 26 April 2007
Resolution: Light fixture removed from vessel.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 18 October 2006
Resolved
Emergency Radio Instructions are not posted. Post instructions at the radio station.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 December 2006
Resolved 26 April 2007
Resolution: Radio instructions posted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 October 2006
Resolved
Remove all dead ended wires on board vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 December 2006
Resolved 26 April 2007
Resolution: Wires removed or properly covered.
Engineering › Bilge Water Management System › Valve
Issued 18 October 2006
Resolved
Electric submersible bilge pump does not have a positive closing valve located in the discharge line. Install a valve in the bilge pump discharge line as instructed by CG inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 December 2006
Resolved 26 April 2007
Resolution: New positive control valve installed inline for electric submersible bilge pump.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 6 April 2006
Resolved
Provide means to lock sewage three way valve in the position to holding tank, provide means to pump out or drain holding tank.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2006
Construction/Loadline › Structures › Deck Plating
Issued 6 April 2006
Resolved
Repair delaminated fiberglass on port aft deck, to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2006
Resolved 10 April 2006
Engineering › Steering Gear System › Hydraulic Hose
Issued 6 April 2006
Resolved
Renew steering system hose ends at steering ram.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2006
Resolved 10 April 2006
Lifesaving › Hand Flares › Expired
Issued 18 October 2004
Resolved
HANDHELD FLARES WERE EXPIRED OR VESSEL DID NOT HAVE PROPER AMOUNT OF ORANGE / RED
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2004
Resolved 16 November 2004
Resolution: DEF FOLLOW UP
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 18 October 2004
Resolved
PROPERLY MARK AND PROVIDE DONNING PLACARD FOR BOTH TYPES OF LIFEJACKETS USED ON BOARD THE VESSEL
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2004
Resolved 16 November 2004
Resolution: DEF FOLLOW-UP
Documentation › Logs/Records › Logbook (official)
Issued 18 October 2004
Resolved
PROVIDE LOG BOOK FOR TRAINING, AND CHARTS FOR VESSEL
Due 19 November 2004
Resolved 16 November 2004
Resolution: DEF FOLLOW-UP
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 18 October 2004
Resolved
MARKED VESSEL HULL WITH NAME /HAILING PORT BOTH SIDES OF BOW AND STERN
Due 19 November 2004
Resolved 16 November 2004
Resolution: DEF FOLLOW-UP
Engineering › Fuel Oil Service System › Filter
Issued 12 April 2004
Resolved
Renew flame shield on RACOR filer assembly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2004
Resolved 16 November 2004
Resolution: CLEARED DURING DEF CHECK
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 6 October 2003
Resolved
PROPERLY INSTALL FIXED FIRE FIGHTING SYSTEM IN ENGINE SPACE. VESSEL RESTRICTED FROM CARRYING PASSENGERS UNTIL APPROVED BY COGNIZANT [name withheld]: Operating Controls
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 November 2003
Resolved 17 November 2003
Engineering › Bilge Water Management System
Issued 6 October 2003
Resolved
INSTALL VISUAL INDICATORS FOR BILGE PUMPS WHEN OPERATING AT CONTROL STATION.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2003
Resolved 6 October 2003
Lifesaving › Buoyant Apparatus
Issued 6 October 2003
Resolved
RENEW RETRO-REFLECTIVE ON LIFE FLOAT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2003
Resolved 7 November 2003
Engineering › Bilge Water Management System
Issued 6 October 2003
Resolved
PROPERLY PLUG PIPING ON PORT SIDE AMIDSHIPS. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2003
Resolved 7 November 2003
Construction/Loadline › Structures
Issued 6 October 2003
Resolved
RENEW FORWARD TRANSERVE FRAME JUST FORWARD OF ENGINE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2003
Resolved 7 November 2003
Fire Fighting
Issued 6 October 2003
Resolved
SUPPLY THREE 2.5 GALLON BUCKETS STENCILED "FIREBUCKET" WITH LANYARDS.
Action required: 705 - Other - as specified
Due 6 November 2003
Resolved 7 November 2003
Navigation › Emergency Steering
Issued 7 October 2002
Resolved
Unable to prove operation of emergency steering
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 7 October 2002
Resolved
Prove operatiom of MDE uanable to start
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2002
Engineering › Bilge Water Management System
Issued 7 October 2002
Resolved
Fwd bilge pump laying in space not in mount LEGACY COMPONENT DESC: Pump
Due 24 October 2002
Resolved 17 October 2002
Engineering › Bilge Water Management System
Issued 7 October 2002
Resolved
Prove proper operation of engine room high water alarm panel
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2002
Construction/Loadline › Markings
Issued 7 October 2002
Resolved
Mark vessel hull port side fwd with Name LEGACY COMPONENT DESC: Vessel Name/Home Port
Due 24 October 2002
Resolved 17 October 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 7 October 2002
Resolved
[name withheld] with retro and vessel name LEGACY COMPONENT DESC: Marking
Due 24 October 2002
Resolved 17 October 2002
Lifesaving › Hand Flares
Issued 7 October 2002
Resolved
Provide watertight case for vessel flares LEGACY COMPONENT DESC: Storage
Due 24 October 2002
Resolved 17 October 2002
Navigation › Electronic Positioning
Issued 7 October 2002
Resolved
Mount EPRIB while vessel is u/w LEGACY COMPONENT DESC: Radio Direction Finding Device
Due 24 October 2002
Resolved 17 October 2002
Lifesaving
Issued 10 October 2001
Resolved
PROVIDE 9 FLARES WITH VALID DATES.
Condition: Unknown
Due 10 October 2001
Resolved 10 October 2001
Fire Fighting
Issued 10 October 2001
Resolved
RECHARGE FIXED FIRE EXT IN ENGINE ROOM.
Condition: Unknown
Due 10 October 2001
Resolved 10 October 2001
Lifesaving
Issued 25 July 2000
Resolved
PROVIDE A TYPE 406 CATEGORY 1 (HYDROSTSTIC RELEASE TYPE) EPIRB AND A VALID NOAA REGISTRATION DECAL.
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Documentation
Issued 23 May 2000
Resolved
VESSEL CAN NOT CARRY PASSENGERS FOR HIRE FOR USCG CERTIFICATION UNTIL INSPECTION CONDUCTED AND COI ISSUED.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Construction/Loadline
Issued 23 May 2000
Resolved
PROVIDE MDE SEA VALVE FOR INSPECTION.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Construction/Loadline
Issued 13 July 1999
Resolved
VESSEL REQUIRED TO PLUG/COVER HOLES IN THE ENGINE ROOM FORWARD BULKHEAD ON THE PORT AND STBD SIDES.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Electrical
Issued 13 July 1999
Resolved
VESSEL REQUIRED TO REPAIR/RENEW THE BATTERY BOX.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Fire Fighting
Issued 13 July 1999
Resolved
THE ENGINE ROOM FIXED FIRE FIGHTING SYSTEM NEEDS TO BE SERVICED.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Construction/Loadline
Issued 13 July 1999
Resolved
VESSEL REQUIRED TO INSTALL A HIGH BILGE LEVEL AUDIBLE AND VISUAL ALARM IN EACH COMPARTMENT CONTAINING A SEA SUCTION VALVE.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Lifesaving
Issued 13 July 1999
Resolved
VESSEL REQUIRED TO REPLACE THE 5 EXPIRED FLARES.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Navigation
Issued 30 June 1998
Resolved
PROVIDE UPDATED CHARTS, COAST PILOT AND TIDE TABLES FOR LIMITED COASTWISE ROUTE AS STATED ON COI.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Lifesaving
Issued 30 June 1998
Resolved
RENEW (1) ADULT PFD AND RENEW RETRO TAPE ON (1) PFD. ADULT PASSENGER CARRIAGE IS LIMITED BY (1) UNTIL PREVIOUS MENTIONED PFD IS IN PLACE.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Lifesaving
Issued 30 June 1998
Resolved
RENEW LINE FESTOONED AROUND RING BUOY.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Navigation
Issued 30 June 1998
Resolved
POLISH/RENEW PORT AND STBD NAV LIGHT LENSES.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Documentation
Issued 30 June 1998
Resolved
ESTABLISH TRAINING LOGS TO DOCUMENT CREW FAMILIARIZATION, ABANDON SHIP, FIRE FIGHTING AND MAN OVERBOARD DRILLS.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Fire Fighting
Issued 30 June 1998
Resolved
PROVIDE (1) ADDITIONAL B-II FIRE EXTINGUISHER TO AUGMENT E/R FIRE FIGHTING ABILITY.
Condition: Unknown
Due 14 July 1998
Resolved 2 July 1998
Construction/Loadline
Issued 16 April 1998
Resolved
A deterioration of the figerglass coating IWO the bottom of the keel, 122- 124" from the stem, 177"-182" from the stem, and 253"-259" from the stem. The areas are deteriorated enough to allow direct access to the foam core inside the keel. Required to repair/renew by 16MAY98.
Condition: Unknown
Due 16 May 1998
Resolved 20 April 1998
Navigation
Issued 16 April 1998
Resolved
The weld on the bracket affixing the rudder gudgeon to the keel is wasted along the entire length of the weld. Required to repair/renew the stainless weld prior to using the vessel of a scheduled charter on 19APR98.The repair was satisfactorily completed the following day (17APR98).
Condition: Unknown
Due 17 April 1998
Resolved 20 April 1998
Documentation
Issued 27 March 1995
Resolved
UNTIL SUCH TIME AS THE VESSEL HAS ON BOARD A VALID FCC STATION LICENSE, THEVESSEL IS RESTRICTED TO OPERATION OF NOT MORE THAN 1000 FEET FROM SHORE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Engineering
Issued 30 March 1992
Resolved
PROVE PROPER OPERATION OF MAIN ENGINE THROTTLE CONTROL.
Condition: Unknown
Due 30 April 1992
Resolved 7 April 1992
Fire Fighting
Issued 16 March 1989
Resolved
INSTALL AUTOMATIC-ENGINE-SHUTDOWN IN FIXED HALON SYSTEM OR PROVIDE MEANS WHEREBY ENGINE TAKES AIR EXCLUSIVELY FROM MAIN DECK OR OTHER SPACE WHERE HALON WILL NOT BE DISCHARGED.
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Lifesaving
Issued 16 March 1989
Resolved
RE-NEW 3 RED FLARES AND 3 ORANGE SMOKE SIGNALS PRIOR TO THEIR EXPIRATION DATE OF 30APR89.
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Engineering
Issued 16 March 1989
Resolved
SECURE FUEL SUPPLY MANIFOLDS AGAINST LOOSENESS AND SECURE FUEL LEAK AT MANIFOLD.
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Engineering
Issued 16 March 1989
Resolved
RE-NEW ENTIRE FUEL PIPING SYSTEM WITH 1/2-INCH O.D. COPPER TUBING, IN ACCORDANCE WITH VESSEL'S APPROVED PLANS.
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Navigation
Issued 16 March 1989
Resolved
DEMONSTRATE PROPER OPERATION OF STERN LIGHT.
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Accommodation/Occupational Safety
Issued 20 July 1988
Resolved
TIGHTEN STANCHION CONNECTIONS TO DECK FOR BOW RAIL AND STEERING STATION/FLYBRIDGE RAIL.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Construction/Loadline
Issued 20 July 1988
Resolved
PROPERLY INSTALL PERMANENT CAPS OVER PLASTIC THROUGH-HULL FITTINGS, ONE PORT SIDE, ONE STARBOARD SIDE ENGINE SPACE.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Navigation
Issued 20 July 1988
Resolved
RE-NEW STEERING HOSE FITTINGS
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Construction/Loadline
Issued 28 March 1988
Resolved
PROPERLY CAULK AND SECURE THE MAIN DECK ACCESS BOARD ON THE PORT SIDE OF THE MAIN ENGINE HATCH.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Construction/Loadline
Issued 28 March 1988
Resolved
INSTALL A CAPTIVE LANYARD ON THE MAIN DECK HATCH COVER FORWARD OF THE ENGINE ROOM HATCH.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Accommodation/Occupational Safety
Issued 28 March 1988
Resolved
PROPERLY SECURE THE RAILINGS FOR THE FLYING BRIDGE WHERE THE TOP RAIL WAS CUT TO SHORTEN THE RAILS.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Documentation
Issued 28 March 1988
Resolved
POST THE CERTIFICATE OF INSPECTION, STABILITY LETTER, RADIO SAFETY & RADIO STATION LICENSES, AND EMERGENCY INSTRUCTIONS TO THE PASSENGERS.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Lifesaving
Issued 28 March 1988
Resolved
REPLACE THE DETERIORATED BOUYANT APPARATUS WITH A PROPER BOUYANT APPARATUS OR LIFE FLOAT OF AT LEAST 9 PERSON CAPACITY.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Lifesaving
Issued 28 March 1988
Resolved
REPLACE 3 ORANGE SMOKE AND 3 RED, HAND HELD FLARES.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Electrical
Issued 28 March 1988
Resolved
REMOVE THE WIRE NUTS AND INSTALL PROPER CONNECTIONS FOR THE ELECTRIC BILGE PUMP FLOAT SWITCH IN THE ENGINE ROOM.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Navigation
Issued 28 March 1988
Resolved
REPAIR OR REPLACE THE STERN LIGHT.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Accommodation/Occupational Safety
Issued 28 March 1988
Resolved
REPLACE THE BUCKLED HOSE AT THE CONNECTION OF THE MSD HOLDING TANK.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988