Documentation record
Registered dimensions (L × B × D)33.8 ft × 13.0 ft × 4.7 ft
Registered tonnagegross 16 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKENNER MARINE AND MACHINERY, INC. · LAPLACE, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDUBUQUE, IA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 14 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 8 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 April 2023
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: (1) Automatic, battery-operated with a duration of no less than 2 hours; or (2) Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. Light in main deck space was missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 7 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 April 2023
Resolved
Each lifebuoy on a towing vessel must: (4) Be marked in block capital letters with the name of the vessel. The vessel name was faded of both ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 7 June 2023
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 April 2023
No resolution recorded
Prior to assuming duties as officer in charge of a navigational watch, a person must: (1) Complete the navigation assessment required by § 140.635. The logs, navigation assessments and drills had not been completed since June 2021.
Condition: Invalid
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 July 2022
Resolved
All owners and operators of an existing towing vessel must have onboard a valid COI prior to the specified phase-in period. This vessel has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection immediately and the vessel may no longer be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 September 2022
Resolution: vessel has met the minnimum requirements for a COI
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 June 2022
Resolved
Main diesel engines alarm panel did not audible sound. Repair or replace ensuring functionality in the wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 13 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 2 June 2022
Resolved
Replace first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 13 September 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 June 2022
Resolved
Renew watertight gaskets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 13 September 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 June 2022
Resolved
Vessel's fuel shutoff valves are not installed in the proximity of the fuel tank(s). Install valves in the vicinity of the fuel tank(s).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 1 August 2022
Resolution: Fuel valves installed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 June 2022
Resolved
Vessel's emergency lighting did not activate. Replace or repair emergency lighting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 9 June 2022
Resolution: Vessel rep repaired or replaced the emergency lighting.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 June 2022
Resolved
Vessel has a paint locker onboard. Vessel is required to install in the vicinity of the paint locker a 40B:C extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 15 July 2022
Resolution: Installed applicable portable fire extinguisher in vicinity of hazmat locker.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2021
Resolved
Install electric water light to starboard ring buoy.
Action required: 10 - Deficiency Rectified
Resolved 2 June 2022
Resolution: Waterlight installed
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 2 June 2021
Resolved
Replace gaskets on all watertight doors and hatches.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 9 September 2021
Resolution: Renewed gaskets
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 2 June 2021
Resolved
Install guards on rotating machinery in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 25 February 2022
Resolution: Operator installed guards.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 June 2021
Resolved
Remove excess oil in engine room bilges, bulkheads and machinery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 2 June 2022
Resolution: Excess oil removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 June 2021
Resolved
Secure the flammable locker to the vessel so as to prevent movement while underway.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 2 June 2022
Resolution: Flammable locker secured.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 June 2021
Resolved
Secure the B-V semi portable fire extinguisher's frame to the vessel to prevent its movement while underway.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 9 September 2021
Resolution: 160B bolted to vessel
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 2 June 2021
Resolved
Mark each watertight door, on both sides with at least one inch high letters, "WATERTIGHT DOOR- KEEP CLOSED"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 9 September 2021
Resolution: Labels placed at locations.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 2 June 2021
Resolved
Mark each escape hatch and emergency exit used as a means of escape on both side with at least 2 inch high letters, "EMERGENCY EXIT, KEEP CLEAR"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 25 February 2022
Resolution: Exits marked
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2021
Resolved
Repair leak on shaft alley discharge piping and prove proper operation of machinery without undue water ingress.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 2 June 2022
Resolution: Shaft alley discharge piping repaired.