GARY DEAN ELEVATOR

GARY DEAN ELEVATOR is a 1980 offshore supply vessel. The Coast Guard has recorded 7 inspections since 2016, most recently in June 2023, along with 19 deficiencies — 8 with no resolution recorded —.

Records from 2016 to 2023. Most recent: inspection, 15 June 2023.

Built
1980
Last inspected
15 June 2023
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

191588
Flag
UNITED STATES
Maury page id
psix-191588

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 6 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)63.1 ft × 40.1 ft × 5.5 ft
Registered tonnagegross 97 / net 72
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS INC · CAERNARVON, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
72 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

15 June 2023 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7716075
14 October 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7332432
9 June 2020 Administrative Inspection · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6971875
22 February 2019 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6630675
21 February 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6358744
3 January 2018 Internal Structural Exam · Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6331998
22 November 2016 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6045689

Deficiency record · 19

11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 14 October 2021 No resolution recorded
A VESSEL OPERATING ON OCEANS ROUTE MUST BE EQUIPPED WITH EPIRB. EPIRB WAS NOT FOUND ONBOARD; REPLACE AS NECESSARY.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 14 October 2021 No resolution recorded
THE EBI ALUMINUM WORKBOAT SERIAL NUMBER 0003 INSTALLED ON THIS VESSEL HAS BEEN ACCEPTED BY MORMS AS MEETING CGD8'S RESCUE BOAT POLICY. RESCUE BOAT 0003 WAS FOUND OOC. REPAIR AS NECESARY.
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 October 2021 No resolution recorded
STEERING APPARATUS MUST BE MAINTAINED IN SUCH A MANNER AS TO AFFORD ADEQUATE PROTECTION FROM CAUSING PERSONNEL INJURY. STEERING GEAR MANIFOLD FOUND TO HAVE A MODERATE LEAK, EMITTING FROM OVERHEAD AND POOLING ON DECK IN RUDDER ROOM. REPAIR AS NECESSARY.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 October 2021 No resolution recorded
EACH VESSEL MUST HAVE ADEQUATE EMERGENCY LIGHTING FITTED ALONG THE LINE OF ESCAPE TO THE MAIN DECK. FOUND (02) LIGHTS OOC (BERTHING & WHEELHOUSE). REPAIR AS NECESSARY.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 October 2021 No resolution recorded
SMOKE DETECTORS MUST BE INSTALLED IN EACH BERTHING / PUBLIC AREA. FOUND (02) DETECTORS OOC. REPLACE AS NECESSARY.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 October 2021 No resolution recorded
EACH LIGHTING FIXTURE MUST HAVE A GUARD OR BE MADE OF HIGH STRENGTH MATERIAL. FOUND (02) LIGHTS IN ENGINE ROOM UNGUARDED & (01) PRIMARY LIGHT MISSING IN MSD SPACE. REPLACE AS NECESSARY.
Action required: 17 - Rectify deficiencies prior to departure
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 14 October 2021 No resolution recorded
WHEN OPERATING WHERE DISCHARGE OF SEWAGE IS PROHIBITED THE MSD MUST BE SECURED FROM OVBD DISCHARGE. MSD WAS FOUND TO BE UNSECURED. REPAIR AS NECESSARY.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 October 2021 No resolution recorded
VESSEL MUST CARRY ADEQUATE AND UP TO DATE CHARTS. CHARTS FOUND NOT CORRECTED SINCE AUGUST 21. CORRECT AS NECESSARY.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 9 June 2020 Resolved
Bow leg bottom platform and upper handrail were fractured. Repair damaged areas to the satisfaction attending inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 23 June 2020
Resolution: Witnessed satisfactory repairs.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 9 June 2020 Resolved
STBD engine room bilge alarm light was not working. Ensure visual indicator actuates with alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 17 June 2020
Resolution: Electrician had installed diodes in reverse. Corrected problem prior to completion of inspection.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 9 June 2020 Resolved
Fire pump suction hose was leaking from hose fittings. Also identified pinholes in hose. Replace hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 23 June 2020
Resolution: Vessel replaced hose and fittings.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 22 February 2019 Resolved
Repair wasted steel on 03 leg platforms.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2019
Resolved 18 March 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 February 2019 Resolved
Replace wasted handrails on the starboard side of the pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2019
Resolved 18 March 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 February 2019 Resolved
Replace all watertight hatch gaskets inside engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2019
Resolved 20 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 February 2019 Resolved
Replace leaking seal on port side rudder ram.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2019
Resolved 20 March 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 February 2019 Resolved
Renew or repair electrical stuffing tubes in the port rudder room bulkhead and tank room centerline bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2019
Resolved 20 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 February 2019 Resolved
Repair port tank void keel cooler leak.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2019
Resolved 20 March 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 February 2019 Resolved
Provide updated charts.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2019
Resolved 20 March 2019
Engineering › Bilge Water Management System › Pump
Issued 22 November 2016 Resolved
PORT TANK ROOM BILGE ALARM AND PUMP WERE INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2016
Resolved 22 November 2016
Resolution: PUMP AND ALARM REPAIRED PRIOR TO END OF INSPECTION.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.