MAURY USCG vessel records Sign in
← All vessels

AZAMARA JOURNEY

AZAMARA JOURNEY is a 2000 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2007, most recently in October 2024, along with 25 deficiencies.

Records from 2007 to 2024. Most recent: inspection, 14 October 2024.

Built
2000
Last inspected
14 October 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9200940 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-19166

Inspections, by type

…with no type recorded3
Years with a record 10 calendar years (2007–2024)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it3376 - Dead Weight, Metric Ton
16146 - Displacement, Metric Ton
30277 - Convention (Subpart B), Gross Ton
30277 - Simplified, Gross Ton
11748 - Convention (Subpart B), Net Ton
11748 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

14 October 2024 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8018932
12 October 2024 COC-CVE Annual · PSC A
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8017386
5 January 2020 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6882992
6 December 2019 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6868030
21 November 2019 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6858432
22 December 2018 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6607337
3 November 2018 ISPS II Exam · COC-CVE Initial · Ballast Water Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6573745
14 March 2016 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5832932
26 January 2016 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5803480
6 January 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5791973
10 December 2015 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5778812
29 November 2010 COC-CVE Annual · Deficiency Check · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3898052
18 December 2009 ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3651990
3 January 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3387906
18 December 2008 ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3381467
10 November 2007 Ballast Water Examination · ISPS II Exam · MARPOL Annex II Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3096232
20 July 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3001627
19 May 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2934406
30 April 2007 PII Safety Exam · COC-CVE Initial · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2916374

Deficiency record · 25

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2019 Resolved
Complete plan review for modifications affecting structural fire protection or means of egress. 46 USC 3505
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2019
Resolved 5 January 2020
Resolution: Satisfied with the plan review provided and the def can be cleared. Those outstanding items will need to be verified during the next COC exam, but that doesn’t preclude clearing the item.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 21 November 2019 Resolved
In addition to complying with the specific provions for fire integrity of bulkheads and decks mentioned elsewhere in this part the minumum fire integrity of all bulkheads and decks shall be as prescribed in tables 26.1 and 26.2 Penetration were found above fire door 325, 211, 346 and ceiling between hydraulic room substation and main galley. 74 SOLAS (2001) Ch II-2 Reg 26.1
Action required: 10 - Deficiency Rectified
Resolved 21 November 2019
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 21 November 2019 Resolved
The oil record book whether as a part of the ships official logbook or otherwise, shall be in the form speficied in appendix III to this annex. Appendix III states that tanks listed in item 3.1 or form A of the supplement to the IOPP certificate should be sounded weekly. The last weekly soundings conducted 03NOV2019 and not logged in the oil record book. MARPOL 2017 Annex I/17.1
Action required: 10 - Deficiency Rectified
Resolved 21 November 2019
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 November 2019 Resolved
All escape route signs and fire equipment location markings shall be of photoluminesent material or marked by lighting. There are escape route signs missing in crew laundry and escape route photoluminesent material signs throughout the vessel are faded and the luminity of the signs needs to be verified. 74 SOLAS (2001) Ch II-2 Reg 28.1.10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2019
Resolved 6 December 2019
Resolution: Received Survey Report from DNV-GL stating escape and exit signage is in order onboard the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 November 2019 Resolved
Contruction of all doors/door frames in "A" class divisions... shall provide resistance to fire as well as passage of smoke and flame. Fire door 362, 370, 367, and Emergency Generator door did not properly close. 74 SOLAS (2001) CH II-2 Reg 30.2
Action required: 10 - Deficiency Rectified
Resolved 21 November 2019
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 3 November 2018 Resolved
All openings in "A" Class divisions shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. The following fire screen doors were not closing properly. Doors #342, 370, 371, 1003, 720 and 904.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2018
Resolved 9 November 2018
Resolution: Vessel provided class report attached to activity attesting to correction of deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › No direct openings into sleeping rooms cargo/mach.
Issued 3 November 2018 Resolved
Means of escape shall be marked and readily identified the escape exits. The photoluminescent sign in location on Deck 10 starboard aft A/C room is not charging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2018
Resolved 9 November 2018
Resolution: Vessel provided class report attached to activity attesting to correction of deficiency.
Fire Fighting › Structural - A Class Divisions › Stairways
Issued 11 December 2015 Resolved
Deck #2 Zone #2 fwd crew stairwell was found by PSCOs wasted and holed at bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 January 2016
Resolved 26 January 2016
Resolution: IAW DNV-GL Class Report, vessel placed a new steel plate insert at Deck 2, FZ 2, FWD crew staircase.
Construction/Loadline › Markings › Load Line Mark
Issued 11 December 2015 Resolved
PSCOs observed port side loadline marking s not permenantly marked Deck line not painted with contrasting color.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 January 2016
Resolved 26 January 2016
Resolution: IAW DNV-GL Class Report load lines were permanently marked by welding at dry-dock. All lines have been painted in contrasting colours.
Lifesaving › Lifeboat › Watertight Enclosure
Issued 11 December 2015 Resolved
#1 strbd lifeboat was found with a warped hatch, located above the operator's station.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 6 January 2016
Resolution: Class report provided
Construction/Loadline › Structures › Door
Issued 29 November 2010 Resolved
A door designed to reopen upon contacting an object in its path shall reopen not more than 1 meter from point of contact. FSD 512, 511 are not reopening when activated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2010
Resolved 11 December 2010
Construction/Loadline › Structures › Door
Issued 29 November 2010 Resolved
A door designed to reopen upon contacting an object in its path shall reopen not more than 1 meter from point of contact. FSD 515 open more than 1 meter when activated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2010
Resolved 11 December 2010
Construction/Loadline › Structures › Door
Issued 29 November 2010 Resolved
"A" class divisions shall provide resistance to fire as well as to the passage of smoke. FSD 524, and 515 did not provide resistance to the passage of smoke upon exam. Class to address issue via survey report/drydock
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 December 2010
Resolved 11 December 2010
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 29 November 2010 Resolved
The transfer procedures required by 33CFR 155.720 must be available for inspection by the COTP or OCMI whenever the vessel is in operation. There are no transfer procedures available for inspection
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 11 December 2010
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 29 November 2010 Resolved
The contents of a space must be appropriate for the space category as per the vessels structural fire protections plan. Combustable materials were found in rooms 713, 503, and 203 which is a space category of 10.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 13 December 2010
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 November 2010 Resolved
Escape route markings must enable passengers to identify the routes of escape. Low location lighting in spa, deck 9 forward is blocked by furniture and trash cans.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2010
Resolved 11 December 2010
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 29 November 2010 Resolved
Fire control plans and booklets shall be kept up to date; any alterations thereto shall be recorded as soon as practicable. Upon reviewing the fire control plan, discovered "A" space, the restraint managers office, marked as a linen space.
Action required: 15 - Rectify deficiencies by next port
Due 6 December 2010
Resolved 11 December 2010
Fire Fighting › Means of Escape › Blocked
Issued 29 November 2010 Resolved
Escape routes shall be maintained in safe condition, clear of obstacles. 2 ATM's were found affixed and blocking escape routes in casino on deck 5.
Action required: 15 - Rectify deficiencies by next port
Due 29 November 2010
Resolved 11 December 2010
Deck/Cargo › Cargo Stowage › General
Issued 29 November 2010 Resolved
The company should ensure that the policy is implemented and maintained at all levels of the organization, both ship based and shore based. Locker 59057, room 516 were found with stowage above the red line.
Action required: 705 - Other - as specified
Due 6 December 2010
Resolved 11 December 2010
Lifesaving › Lifeboat › Skate
Issued 29 November 2010 Resolved
Each survival craft shall be stowed in a state of continuous readiness and under unfavorable conditions of trim of up to 10 degrees and listed up to 20 degrees either way. Tenders 3 and 5 did not have skates attached to tender preventing the vsl to meet the list requirements in SOLAS
Action required: 705 - Other - as specified
Due 13 December 2010
Resolved 29 November 2010
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 10 November 2007 Resolved
Demonstrate satisfactory operation of Port Side lifeboats. Operation may be video taped and sent to USCG.
Due 10 December 2007
Resolved 8 December 2007
Resolution: Def. cleared.
Personnel › Training › Safety Orientation
Issued 10 November 2007 Resolved
Demonstrate policy of operation of water tight doors during a firefighting exercise & how to operate the door in coordination with the fire fighting teams operating in the affected areas.
Due 17 November 2007
Resolved 8 December 2007
Resolution: Rec''d fax attesting to satisfactory compliance. Def cleared.
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 May 2007 Resolved
Conduct a modified Transitional Power Test for 30 minutes after the new batteries have been installed. Test to be completed in the presence of Class and USCG.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 19 May 2007
Resolution: Conducted modified Transitional Source of Power test for 30 minutes, voltage drop 220 to 210, all satisfactory
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 4 May 2007 Resolved
Update the Fire and Control Plan as marked on the plan. Provide proof of BV approved revision "E" title box.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 20 July 2007
Resolution: Received confirmation and copy of updated plans marked by BV
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 4 May 2007 Resolved
Update Notice of Arrival to reflect the correct owner from Royal Caribbean to Celebrity Journey Inc.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 4 May 2007

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.