Records from 2000 to 2013. Most recent: casualty investigation, 24 April 2013.
Inspection history · 20
22 May 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4317447
18 March 2009
Periodic Inspection · Hull Examination · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3445649
17 June 2008
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3239492
15 December 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3131381
10 July 2007
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2990894
29 March 2006
Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2608397
23 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571372
5 May 2005
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2349782
4 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303573
10 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290091
28 October 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2230344
15 July 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2134319
13 April 2004
Cargo Tank Internal · Re-Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2043331
16 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1967026
18 July 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1849901
19 July 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1648723
20 April 2001
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370219
30 September 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1054953
31 July 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821325
31 March 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1047253
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 March 2009
Resolved
Procure updated light list and keep onboard.
Due 2 May 2009
Resolved 1 June 2010
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 March 2009
Resolved
Replace defective waterlight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2009
Resolution: Waterlight replaced.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 18 March 2009
Resolved
Repair broken light for embarkation station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2009
Resolution: Light repaired.
Documentation › Markings/Placards › Warning Signs
Issued 17 June 2008
Resolved
Post a lifesaving signals and helicopter recovery placard onboard vsl.
Action required: 705 - Other - as specified
Resolved 17 June 2008
Documentation › Markings/Placards › Warning Signs
Issued 17 June 2008
Resolved
Post an emergency instructions placard onboard vsl.
Action required: 705 - Other - as specified
Resolved 17 June 2008
Lifesaving › Lifefloat › Float-free Link
Issued 10 July 2007
Resolved
renew on starboard side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 July 2007
Resolved
label all life jacket stowage locations with quantity.
Due 11 August 2007
Resolved 10 July 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 July 2007
Resolved
renew light on Port side of bridge life ring.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 July 2007
Resolved
renew tape on all life rings as needed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 10 July 2007
Resolved
Provide (2) 20 lb. Dry Chem portable fire extinguishers to be used for MPT carriage approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2007
Fire Fighting › Means of Escape › Blocked
Issued 10 July 2007
Resolved
replace screen door handle in accomodation space that covers the WTD. Door must be easily opened.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 10 July 2007
Resolved
Post piping diagram at pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 10 July 2007
Resolved
label shut down on main deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2007
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 10 July 2007
Resolved
provide rescue harness and lifeline
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 May 2005
Resolved
Show proper operation of Oily Water Separator prior to 05 JUNE 2005.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 23 May 2005
Resolution: Green Marine tested system with satisfactory results.
Engineering › Fuel Oil Service System
Issued 18 July 2003
Resolved
PROVIDE FLAME BOWLS FOR ALL RAYCOR FILTER HOUSINGS. LEGACY COMPONENT DESC: Filter
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 August 2003
Resolved 18 July 2003
Engineering › Compressed Air System (control) › Valve
Issued 18 July 2003
Resolved
REPAIR OR RENEW RELIEF VALVES ON BOTH ENGINE ROOM AIR RECEIVERS.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2003
Resolved 18 July 2003
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 18 July 2003
Resolved
REPAIR FUEL OIL LEAK ON FUEL OIL HAND PRIMING PUMP.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2003
Resolved 18 July 2003
Lifesaving › Buoyant Apparatus
Issued 18 July 2003
Resolved
CORRECT LIFE FLOAT PAINTER ARRANGEMENT. LEGACY COMPONENT DESC: LIFE FLOATS
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2003
Resolved 18 July 2003
Lifesaving › Lifebuoys
Issued 18 July 2003
Resolved
RENEW RETRO-REFLECTIVE TAPE ON TWO LIFE RINGS. LEGACY COMPONENT DESC: RETRO-REFLECTIVE TAPE
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2003
Resolved 18 July 2003
Construction/Loadline › Structures › Scuttle
Issued 18 July 2003
Resolved
RENEW GASKET ON ENGINE ROOM EMERGENCY ESCAPE HATCH.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2003
Resolved 18 July 2003
Operations/Management › Drills/Instruction › Fire
Issued 19 July 2002
Resolved
REQUIRED DRILLS NOT BEING LOGGED PROPERLY.
Due 19 August 2002
Resolved 19 July 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 19 July 2002
Resolved
FUEL OIL AND METHANOL HOSES NOT ANNUALLY TESTED.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2002
Resolved 19 July 2002
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 July 2002
Resolved
LIFE RING NOT STENCILED WITH SHIPS NAME OR HAILING PORT.
Due 19 August 2002
Resolved 19 July 2002
Fire Fighting › Fire Hoses
Issued 19 July 2002
Resolved
NO VESSEL NAME MARKED ON FIRE HOSES. LEGACY COMPONENT DESC: MARKINGS
Due 19 August 2002
Resolved 19 July 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 19 July 2002
Resolved
NO STORM RAILS INSTALLED ON GALLEY STOVE TOP. LEGACY COMPONENT DESC: STORM RAILS
Due 19 August 2002
Resolved 19 July 2002
Lifesaving › Hand Flares › Storage
Issued 19 July 2002
Resolved
STORAGE BOX NEEDS TO BE A BRIGHT COLOR.
Due 19 August 2002
Resolved 19 July 2002
Navigation › Emergency Steering
Issued 19 July 2002
Resolved
NO EMERGENCY STEERING INSTRUCTIONS POSTED AT ENGINEROON STEERING STATION. LEGACY COMPONENT DESC: EMERGENCY INSTRUCTIONS
Due 19 August 2002
Resolved 19 July 2002
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 19 July 2002
Resolved
REPLACE BOTH RELIEF VALVES WITH VALVES THAT RELIEF BELOW THE MAWP OF THE RECEIVER.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2002
Resolved 19 July 2002
Stability › Watertight Integrity
Issued 19 July 2002
Resolved
ADJUST FORWARD ENGINROOM, PORT ENGINEROOM AND PILOTHOUSE WATERTIGHT DOORS. LEGACY COMPONENT DESC: DOORS
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2002
Resolved 19 July 2002
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 19 July 2002
Resolved
DOUBLE NUT BOTH SHAFTS PACKING GLANDS.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2002
Resolved 19 July 2002
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 July 2002
Resolved
INSTALL A EMERGENCY LIGHT TO ILLUMINATE STAIRWAY LEADING TO ENGINEROOM WATERTIGHT DOOR.
Due 19 August 2002
Resolved 19 July 2002