Records from 2000 to 2025. Most recent: inspection, 15 December 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 29
15 December 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8283770
6 September 2024
Administrative Inspection · Examination of Repairs · Drydock Exam · COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7997977
14 November 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7824815
8 February 2023
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7634017
15 August 2022
COI Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7534029
2 June 2022
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7466460
11 August 2021
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7283902
22 July 2020
Internal Structural Exam · Annual Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7023342
6 May 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6949184
15 October 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6835026
7 May 2019
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6678783
5 April 2018
Administrative Inspection · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6385892
28 September 2017
Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6277257
4 October 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6015359
13 April 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5853580
9 October 2015
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5739696
10 October 2014
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5002199
20 January 2011
Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3931653
12 January 2009
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3392517
10 October 2007
Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3077123
5 March 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2882881
9 February 2007
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2872013
22 November 2005
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2539062
10 November 2005
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2532196
11 October 2005
Internal Structural Exam · Annual Inspection · Administrative Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2512549
2 December 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1713194
30 October 2002
COI Inspection · Deficiency Check · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1698583
16 May 2001
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1433833
7 July 2000
Plan Review "T" Boat · Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1381946
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 17 December 2025
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight.
Port exhaust pipe through aft of E/R watertight bulkhead found broken through weld into space behind and another crack in weld just above pipe from previous repair.
An additional cracked framing weld right next to port exhaust pipe was found in the same area.
Vessel shall enact permanent repairs to the satisfaction of the Coast Guard.
46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 January 2026
Resolution: Company submitted photos. See attached under documents.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 October 2024
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Cylinders must be retested at least every 12 years.
CO2 cylinders are overdue for hydrostatic testing and were severely corroded.
Provide satisfactory evidence that a hydrostatic test has been conducted or replace bottles.
46 CFR 176.810(b)(2)
46 CFR 147.65(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2024
Resolution: Record of satisfactory hydrostatic test provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 October 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis
of crewmembers on inspected vessels.
Vessels crew is not currently enrolled with any maritime
consortium and does not have proof of recent negative
drug testing results.
Provide testing evidence for all crew required above.
46 CFR 16.230(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2024
Resolution: Negative testing records provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 October 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
First aid kit missing required items.
Replace with kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 December 2024
Resolution: Received photo of newly purchased first aid kit that meets ISO requirements.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 October 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI.
Vessel did not have any alcohol testing devices on board.
Ensure adequate number of devices are on board or can be obtained within 2 hours.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2024
Resolution: Office provided vessel with an adequate number of alcohol testing strips.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 October 2024
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry:(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard
specified by the Commandant.
Distress signal kit missing 01 smoke signal.
Add additional smoke signal or hand red flare.
46 CFR 180.68(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2024
Resolution: Vessel rep purchased an additional smoke flare and properly labeled casing.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 October 2024
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
Vessel missing 01 portable light.
Add additional portable light.
46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2024
Resolution: Vessel rep purchased additional portable light.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 September 2024
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
A Certificate of Inspection may be suspended and withdrawn or revoked by the cognizant OCMI at any time for noncompliance with the requirements of this subchapter.
Vessel is past due on required Drydock and Internal Structural Examinations. Vessel COI has been revoked.
Vessel must complete Drydock and Internal Structural Examinations. Afterward, vessel must successfully complete COI renewal to the satisfaction of a Coast Guard Marine Inspector prior to returning to normal operations.
46 CFR 176.600
60 C
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 October 2024
Resolution: Vessel completed DDE/ISE and COI Inspections.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 November 2023
Resolved
A vessel of 12 metres or more in length shall be provided with a whistle and a bell.
Sound producing device inoperable. Repair and demonstrate proper operation.
33 CFR 83.33
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 December 2023
Resolution: New sound producing device on board vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 November 2023
Resolved
Except as otherwise provided in this section, propulsion machinery installations must comply with the provisions of this part.
Deteriorated hose on Port Main Diesel Engine expansion tank. Replace hose.
46 CFR 182.220
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2023
Resolved 15 December 2023
Resolution: New hose installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 November 2023
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip.
Life ring light not attached to life ring with clip. Provide required corrosion resistant clip.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2023
Resolved 15 December 2023
Resolution: Correctly attached life ring light to life ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 November 2023
Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] sea strainer valve leaking. Repair and
demonstrate proper operation
46 CFR 182.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2023
Resolved 15 December 2023
Resolution: Sea strainer repaired.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 14 November 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible
Neither electronic charts or paper charts are up to date. Provide new paper charts or update existing electronic chart system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2023
Resolved 18 December 2023
Resolution: New electronic chart instlled on board.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 November 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
Hole in aft deck elevated platform over lazarette. Repair as original.
Open conduit piping port side main deck to engine room. Make watertight.
46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2023
Resolved 15 December 2023
Resolution: Welded aft elevated platform and closed hole.
Conduit piping made watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 August 2022
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds
Steering system is binding on rudder packing retaining bolt. Repair and demonstrate proper operation.
46 CFR 182.610
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2022
Resolution: Video showing repair and proper operation of steering provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 August 2022
Resolved
A visual and audible alarm must be provided to indicate a high water level machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space.
1. Engine compt bilge alarm inoperable. Repair and demonstrate proper operation.
2. Fwd compartment bilge alarm visual indicator inoperable. Repair and demonstrate proper operation.
46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 16 November 2023
Resolution: Engine room bilge alarm repaired, FWD compartment visual indicator remains inoperable, changed to code 16.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew from electrical hazards.
Generator control box has exposed opening. Provide blank to ensure closure of equipement opening.
46 CFR 183.200 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2022
Resolved 16 November 2023
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 August 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible.
Provide updated copy of charts on board vessel.
46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2022
Resolved 16 November 2023
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 15 August 2022
Resolved
The provisions of Part III of Title III of the Communication Act require United States vessels which transport more than six passengers for hire while such vessels are being navigated on any tidewater within the jurisdiction of the United States adjacent or contiguous to the open sea, or in the open sea to carry a radiotelephone installation complying with this subpart
Provide FCC Radio Safety Telephony Certificate as required for small passenger vessels.
47 CFR 80.901
47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 13 December 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 May 2020
Resolved
A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a dry dock examination and internal structural examination at least once every five years. Due to Covid-19, your dry dock and internal structural examinations have been extended and must now be completed by 30 July, 2020.
46CFR176.600(c)(2)
Action required: 705 - Other - as specified
Due 30 July 2020
Resolved 22 July 2020
Resolution: Vessel on blocks conducting shipyard work.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 October 2019
Resolved
The prior months to the inspection did not have drills logged. Drills will be conducted again to the satisfaction of the attending Marine Inspector prior to operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 17 October 2019
Resolution: Vessel is loggin drills and now has a placard reminding the Captain to to monthly drills.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 October 2019
Resolved
During MOB drill crew member had a hard time locating the first-aid kit. The contents on the first-aid kit were inadequate.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 October 2019
Resolved 17 October 2019
Resolution: A new first aid kit was placed onboard complying with Coast Guard standards.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 14 May 2019
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician. Vessel's radio installation has not been certified by a FCC-licensed technician. FCC Safety Radio Telephony Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 14 June 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 14 May 2019
Resolved
Each ship transporting more than 6 passengers for hire equipped with a radio telephone station must carry a radio operator. Master/crew did not have marine radio operators permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 14 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 May 2019
Resolved
A voltmeter and an ammeter shall be provided that can be used for measuring voltage and current of each generator. For AC generators a frequency meter must also be provided. Provide voltmeter, ammeter, and hertz meter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 14 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2019
Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). For the [name withheld] one (1) fixed power pump and one (1) portable hand pump is required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 14 June 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 May 2019
Resolved
A placard must be posted next to all radiotelephone installations with vessel specific emergency broadcast instructions and information. Provide ship specific emergency broadcast placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 14 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 May 2019
Resolved
Remote fuel shutoff stations shall be marked in at least 1- inch letters indicating purpose of the valve. Provide new markings for emergency fuel shutoff valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 14 June 2019
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 12 January 2009
Resolved
There is excesive oily slop in the bilges.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Engineering › Bilge Water Management System › Piping
Issued 12 January 2009
Resolved
The bilge alarm in the steering compartment is unwired.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 January 2009
Resolved
The port engine has an exhaust leak.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 12 January 2009
Resolved
The breakers in the electrical panel are not labeled.
Action required: 705 - Other - as specified
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 January 2009
Resolved
The machinery space fixed CO2 system hasn't been serviced since Feb 2007.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2009
Resolved 12 January 2009
Resolution: Attended vessel, cleared deficiency.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 March 2007
Resolved
Install a fire detection system in the machinery space that the circuit is electrically supervised as per 46 CFR 181.400(c). The installed smoke detection system must be tested by the operator every 14 days and logged in the ships log. If the system is found to be inoperative it must be repaired prior to operating the vessel and the local USCG OCMI notified.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 11 June 2007
Resolution: Fire detection system installed and tested.
Engineering › Bilge Water Management System › Not Operational
Issued 9 February 2007
Resolved
Prove proper operation of the bilge high level alarm in the machinery space and rudder compartment.
Action required: 705 - Other - as specified
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 9 February 2007
Resolved
Renew the cut water line on the stbd MDE.
Action required: 705 - Other - as specified
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Engineering › Fuel Oil Service System › Hose
Issued 9 February 2007
Resolved
Renew the dry rotted fuel line on the Port MDE.
Action required: 705 - Other - as specified
Due 9 February 2007
Resolved 5 March 2007
Resolution: Item corrected.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 February 2007
Resolved
Complete the annual servicing on the fixed CO2 fire extinguisher.
Action required: 705 - Other - as specified
Due 9 March 2007
Resolved 9 September 2020
Resolution: Item corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 February 2007
Resolved
Provide a first aid kit.
Action required: 705 - Other - as specified
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 February 2007
Resolved
Post a "Emergency Broadcast Placard" at the operators station.
Action required: 705 - Other - as specified
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 February 2007
Resolved
Provide a current edition of Tide Tables, Tide Current Tables, USCG Light List and Charts of the Area.
Action required: 705 - Other - as specified
Due 9 March 2007
Resolved 5 March 2007
Resolution: Item corrected.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 October 2005
Resolved
Prior to operating the vessel complete credit drydock, Internal structural and Annual inspections.
Due 21 October 2005
Resolved 17 October 2005
Resolution: Inspections conducted.
Documentation › Certificates/Documents › FCC SSL
Issued 11 October 2005
Resolved
Provide the FCC Station License.
Due 18 November 2005
Resolved 18 November 2005
Resolution: Item corrected.
Construction/Loadline › Hull › Hull Plating
Issued 11 October 2005
Resolved
Repair fractured hull plate on the port bow with a minimum 18" x 18" insert
Due 17 November 2005
Resolved 18 November 2005
Resolution: Item corrected.
Engineering › Fuel Oil Service System › Valve
Issued 11 October 2005
Resolved
Repair the emergency fuel shutoff valve to the fuel tank and prove proper operation.
Due 17 November 2005
Resolved 18 November 2005
Resolution: Item corrected.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 11 October 2005
Resolved
Place double clamps on the hose for the port engine keel cooler fresh water inlet.
Due 17 November 2005
Resolved 18 November 2005
Resolution: Item corrected.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 11 October 2005
Resolved
Repair or replace the port and starboard battery boxes in the machinery space.
Due 17 November 2005
Resolved 18 November 2005
Resolution: Item corrected.
Engineering › Steering Gear System › Fastener
Issued 11 October 2005
Resolved
Double nut the bolts on the steering system.
Due 17 November 2005
Resolved 18 November 2005
Resolution: Item corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 October 2005
Resolved
Provide guards for the light fixtures in the passenger cabin.
Due 17 November 2005
Resolved 18 November 2005
Resolution: Item corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 October 2005
Resolved
Properly connect the electrical wiring for the VHF radio.
Due 18 November 2005
Resolved 11 October 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 30 October 2002
Resolved
Provide copy of fixed fire fighting servicing certificate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 2 December 2002
Resolution: Received copy of fixed fire fighting service certificate. Service was completed 14Nov02.
Documentation › Logs/Records
Issued 30 October 2002
Resolved
Provide training log.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 2 December 2002
Resolution: Training log information put in Bridge log along with lifesaving maintenance record.
Documentation › Logs/Records
Issued 30 October 2002
Resolved
Provide lifesaving manual that lists inspections/checks of l/s equipment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 2 December 2002
Resolution: Lifesaving maintenance record kept in Bridge log.
Lifesaving › Buoyant Smoke Signals
Issued 30 October 2002
Resolved
mark box w/ "distress signals"
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 2 December 2002
Resolution: Distress signal box properly marked.
Lifesaving › Lifejacket/PFD (Type I)
Issued 30 October 2002
Resolved
Replace retro-reflective tape on three lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 November 2002
Resolved 5 November 2002
Electrical › Lighting (service)
Issued 30 October 2002
Resolved
Provide a light cover for lightbulb located in CO2 room. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 2 December 2002
Resolution: Lightcover placed on lightbulb in the CO2 room.