MAURY USCG vessel records Sign in
← All vessels

SPIKE AFRICA

SPIKE AFRICA is a 1977 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1985, most recently in April 2025, along with 122 deficiencies.

Records from 1985 to 2025. Most recent: inspection, 7 April 2025.

Built
1977
Last inspected
7 April 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM3727
192126
Flag
UNITED STATES
366566000
Maury page id
psix-192126

Inspections, by type

…with no type recorded17
Years with a record 35 calendar years (1985–2025)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)54.3 ft × 15.5 ft × 7.5 ft
Registered tonnagegross 42 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBERT M SLOAN · COSTA MESA, CA, UNITED STATES · built 1977
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeShip
Hull configurationMonohull
Hailing portFRIDAY HARBOR, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it42 - Simplified, Gross Ton
33 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM3727MMSI 366566000 · active · compulsorily equipped · granted 20 May 2021, expires 20 May 2031
WDF4869MMSI 366566000 · expired · compulsorily equipped · granted 11 June 2010, cancelled 15 August 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 78

7 April 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8108410
20 June 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7938452
21 February 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7868447
15 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7714484
22 March 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7654644
19 July 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7512879
18 March 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7421010
17 May 2021 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7199529
24 March 2021 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7194414
6 July 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6998456
11 October 2019 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6809601
27 June 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6727546
25 October 2018 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6564801
27 March 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6438562
8 March 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6368447
23 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6360520
31 May 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6153889
25 May 2016 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5887378
8 December 2015 Drydock Exam · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5777341
20 June 2014 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4894555
20 June 2014 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4897281
20 June 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4898582
2 May 2012 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4296164
7 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203868
3 May 2005 Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2348768
27 November 2004 Type not recorded
No type recorded · USCGC KITTIWAKE (WPB 87316) · USCG Oceania District (CGD-O) · Activity 2273115
27 November 2004 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2274422
24 September 2004 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2174564
24 September 2004 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2204042
14 November 2003 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2021674
3 November 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1933728
2 December 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1711406
21 May 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1618126
3 January 2002 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1475364
10 December 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 772726
26 October 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1393797
2 August 2001 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1432554
1 August 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 149022
15 February 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1465063
25 August 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1053499
16 August 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1468153
20 July 2000 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1467687
1 November 1999 COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372849
19 May 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 802542
2 April 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1120527
29 March 1999 Damage Survey · Permit to Proceed · Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1411781
9 April 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1381221
6 January 1998 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 769809
31 December 1997 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 209368
25 November 1997 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 112499
31 July 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1116815
21 May 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1407892
24 April 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1400558
14 May 1996 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1453232
15 April 1996 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1081787
30 May 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1405712
22 November 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 869980
13 July 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1176342
3 June 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1326436
10 June 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 835207
22 January 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 681174
7 January 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 22066
24 November 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1139367
11 June 1992 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1267534
11 June 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335844
19 November 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1297344
15 June 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1231987
9 November 1989 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1353040
1 November 1989 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1285201
7 June 1989 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1341419
17 May 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1340157
29 June 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1207678
2 June 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 888562
16 March 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1030651
22 June 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1006357
6 October 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1315670
26 June 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1303947
2 July 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1295410

Deficiency record · 122

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 June 2023 Resolved
Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the vessel. The count shall be available to the Coast Guard upon request. Passenger counts are only logged on board the vessel and not available ashore. 46CFR185.504
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2023
Resolution: Container placed on dock at vessel slip to house passenger counts.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 19 July 2022 Resolved
Provide objective evidence for the following: -Proof of pre-employment testing for all current and previously employed crewmembers since the beginning of your operations. Crew not currently enrolled in DAPI program due to no planned operations.Vessel has not operated since fall of 2021 and does not plan to operate in 2022. Crew are not currently enrolled in a drug and alcohol testing program. Crew must be enrolled and tested prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2022
Resolved 21 June 2023
Resolution: Enrollment in The Maritime Consortium, Inc, program.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 July 2022 Resolved
The master of each vessel shall ensure that: (b) the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. EPIRB battery was expired. EPIRB battery is expired. Vessel restricted to less than 3NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2022
Resolved 19 August 2022
Resolution: Battery replaced
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 July 2022 Resolved
Vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers. Bilge high water alarm in compartment number 2 not operational.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2022
Resolved 28 July 2022
Resolution: Replaced bilge high water alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 July 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Loose wire in engine room was not properly terminated and junction box in main cabin was missing a cover.Wire in engine room was not connected to any machinery. Junction box in port main cabin did not have a cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2022
Resolved 28 July 2022
Resolution: Installed cover on junction box and removed wire in engine room.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 19 May 2021 Resolved
46 CFR 10.301 / 16c - PROVIDE VALID MEDICAL CERTIFICATE FOR MASTER
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 20 May 2021
Resolution: Operator provided copy of valid certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2021 Resolved
46 CFR 16.113 / 701c - PROVIDE PROOF OF ENROLLMENT IN A CHEMICAL TESTING PROGRAM FOR ALL EMPLOYEES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2021
Resolved 20 May 2021
Resolution: Received proper documentation of chemical testing program.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2021
Resolved 20 May 2021
Resolution: Received proper documentation of chemical testing program.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2021 Resolved
47 CFR 80.903 / 16c - RENEW EXPIRED SAFETY RADIOTELEPHONY CERTIFICATE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 29 May 2021
Resolution: RECEIVED COPY OF UPDATED SAFETY RADIOTELEPHONY CERT.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2021 Resolved
47 CFR 80.13 / 16c - RENEW EXPIRED STATION LICENSE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 20 May 2021
Resolution: Operator provided copy of valid station license.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2021 Resolved
46 CFR 181.520 / 16c - PORTABLE FIRE EXTINGUISHER BELOW AFT STAIRWELL SHALL BE CLEARLY VISIBLE. MOVE EXTINGUISHER TO CLEARLY VISIBLE LOCATION OR MARK WITH APPROPRIATE PLACARD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 29 May 2021
Resolution: OPERATOR AFFIXED PLACARD TO CLEARLY INDICATE THAT AN EXTINGUISHER IS BELOW THE STAIRS IN THE ACCOMODATION SPACE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2021 Resolved
46 CFR 184.240 / 705c - LPG SYSTEMS SHALL MEET INSTALLATION AND TESTING OF ABYX A-1. GAS LEAK DETECTOR INOPERABLE. SYSTEM SHALL BE SECURED AT THE PROPANE TANKS UNTIL PROPER OPERATION OF GAS DETECTION SYSTEM DEMONSTRATED TO A MARINE INSPECTOR.
Action required: 705 - Other - as specified
Due 19 May 2021
Resolved 20 May 2021
Resolution: Recived video proving proper operation of LPG leak detection and subsequent securing of solenoid valve.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 July 2020 Resolved
Vessel operator requested to place the vessel into Laid-up status. The vessel shall undergo a complete COI inspection, ISE and DDX examination prior to carrying passengers IAW 46CFR176.404 and 46CFR176.600. The vessels dry-dock and internal structure exam are extended from March 2020 to March 2021. The Inspection for Certification is deferred without loss of grandfathering privileges until 20 July 2021.
Action required: 705 - Other - as specified
Due 31 July 2021
Resolved 8 June 2021
Resolution: DDX/ISE complete.
Navigation › Piloting/Steering › Marine Charts
Issued 25 May 2016 Resolved
Update paper or electronic charts. 46 CFR 184.420
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 1 June 2016
Resolution: Vessel procured chip with updated charts for navigation system and area of operation.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 25 May 2016 Resolved
Provide proof of drug and alcohol program enrollment for crew. 46 CFR 16.210
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 1 June 2016
Resolution: Vessel provided updated drug and alcohol program document.
Documentation › Certificates/Documents › Stability Letter
Issued 25 May 2016 Resolved
Post current Stability Letter. 46 CFR 176.306
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 1 June 2016
Resolution: Vessel provided photo of posted stability letter.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 August 2004 Resolved
This vessel is currently 3 months past due the required hull inspection. This CG-835 is a follow up to a verbal notification by the [name withheld], Prevention, Inspection Department that vessel shall not be permitted to carry passengers until a hull inspection has been completed by a Coast Guard inpsector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2010
Resolution: Completed fastener, drydock, and internal structural exam this date.
Operations/Management › Drug and Alcohol Testing
Issued 3 November 2003 Resolved
Provide a copy of the 2002 annual CG drug test report. LEGACY COMPONENT DESC: Recordkeeping
Condition: Unknown
Due 15 November 2003
Resolved 14 November 2003
Resolution: Reviewed SAT
Lifesaving › Lifejacket/PFD (Type I)
Issued 3 November 2003 Resolved
Provide two adult and one child lifejacket in compliance with the vessels COI. Passengers reduce by 1 child and two adults until deficiency is resolved. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 15 November 2003
Resolved 14 November 2003
Resolution: Inspected SAT
Lifesaving › Lifejacket/PFD (General)
Issued 3 November 2003 Resolved
Properly mark child lifejacket stowage. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 15 November 2003
Resolved 14 November 2003
Resolution: Inspected SAT
Fire Fighting › Structural Fire Protection - General
Issued 3 November 2003 Resolved
Renew deteriorated bulkhead insulation in the engine room LEGACY COMPONENT DESC: Accommodation Space Protection
Condition: Improper/Lack of Maintenance
Due 31 January 2004
Resolved 14 November 2003
Resolution: Inspected SAT
Fire Fighting › Fixed Fire Detection System
Issued 3 November 2003 Resolved
Provide smoke detectors for the forward cabin and the engine room. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Improper Installation
Due 15 November 2003
Resolved 14 November 2003
Resolution: Inspedted SAT
Communications › Radio Communications
Issued 3 November 2003 Resolved
Provide current EPIRB registration. Route limited to within 3 NM from shore. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 15 November 2003
Resolved 14 November 2003
Resolution: inspected SAT
Documentation › Certificates/Documents
Issued 2 December 2002 Resolved
Provide valid Certificate of Documentation LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 December 2002
Lifesaving › Visual Distress Signals (General)
Issued 2 December 2002 Resolved
Provide 6 flares and 6 smoke signals IAW 46 CFR 180.68(d). Restricted to Lakes, Bays and Sounds route until provided.
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Lifesaving › Visual Distress Signals (General)
Issued 2 December 2002 Resolved
Mark distress signals container IAW 46 CFR 185.614 LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Engineering › Sea-water System (primary cooling)
Issued 2 December 2002 Resolved
Replace duct taped hose on MDE cooling system IAW 46 CFR 182.420. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Electrical › Electric Generation Source (service)
Issued 2 December 2002 Resolved
Secure electrical cover outboard of generator in engineroom IAW 46 CFR 183.340. LEGACY COMPONENT DESC: Panelboard
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Electrical › Electric Supply System (service)
Issued 2 December 2002 Resolved
Cover batteries in engineroom IAW 46 CFR 183.354.
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Electrical › Electric Supply System (service)
Issued 2 December 2002 Resolved
Hard wire electrical device in engineroom starboard aft bulkhead IAW 46 CFR 183.200.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Lifesaving › Lifejacket/PFD (General)
Issued 2 December 2002 Resolved
Provide PFD donning placard.
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Lifesaving › Lifebuoys
Issued 2 December 2002 Resolved
Provide new lanyard to waterlight IAW 46 CFR 180.70 (d). LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Lifesaving › Lifebuoys
Issued 2 December 2002 Resolved
Properly attach retroreflective tape to ring buoy IAW 46 CFR 185.604(b)(i).
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 2 December 2002 Resolved
Replace expired items in first aid kit IAW 46 CFR 184.710. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Lifesaving
Issued 2 December 2002 Resolved
Provide properly registered EPIRB IAW 46 CFR 180.64. To be completed prior to carrying passengers for hire, except on Lakes, Bays, and Sounds route.
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Operations/Management › Drug and Alcohol Testing
Issued 2 December 2002 Resolved
Provide annual drug testing report IAW 46 CFR 16.230.
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Fire Fighting › Means of Escape
Issued 2 December 2002 Resolved
Remove obstructions in way of escape hatch and provide proper stowage IAW 46 CFR 177.500. LEGACY COMPONENT DESC: Doorways
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Electrical › Lighting (service)
Issued 2 December 2002 Resolved
Provide lens covers on electrical fixtures in forepeak IAW 46 CFR 183.200. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Electrical
Issued 2 December 2002 Resolved
Provide box connectors for heating wiring in engineroom IAW 46 CFR 183.200.
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 8 January 2003
Documentation › Certificates/Documents
Issued 2 December 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 10 January 2003
Resolution: Owner provided copy of his FCC license
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 December 2002 Resolved
Provide 2 operating portable batter lights IAW 46 CFR 183.430.
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 4 December 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 3 January 2002 Resolved
Provide 13 adult type 1 life jackets, for a total of 38 as per COI. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 January 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 3 January 2002 Resolved
Provide 02 type 1 childrens life jackets for a total of 04, IAW COI. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 January 2002
Electrical
Issued 26 October 2001 Resolved
Use or remove dead-ended wiring for oild horn.
Condition: Unknown
Due 26 October 2001
Resolved 26 October 2001
Electrical
Issued 26 October 2001 Resolved
Make emerg. lighting in forward berthing operable.
Condition: Unknown
Due 26 October 2001
Resolved 26 October 2001
Accommodation/Occupational Safety
Issued 26 October 2001 Resolved
Stencil forward escape hatch.
Condition: Unknown
Due 15 November 2001
Resolved 31 January 2002
Navigation
Issued 26 October 2001 Resolved
Paint running light shields black.
Condition: Unknown
Due 26 October 2001
Resolved 26 October 2001
Fire Fighting
Issued 26 October 2001 Resolved
Provide annual servicing for fixed fire-fighting system.
Condition: Unknown
Due 26 October 2001
Resolved 26 October 2001
Lifesaving
Issued 26 October 2001 Resolved
Provide 13 adult type one PFD's.
Condition: Unknown
Due 15 November 2001
Resolved 31 January 2002
Lifesaving
Issued 26 October 2001 Resolved
Provide 02 childs PFD's.
Condition: Unknown
Due 15 November 2001
Resolved 31 January 2002
Lifesaving
Issued 26 October 2001 Resolved
Remove oil from engine room bilges.
Condition: Unknown
Due 26 October 2001
Resolved 26 October 2001
Fire Fighting
Issued 26 October 2001 Resolved
Service or remove B-II fire extinguisher from engine room. This extiguisheris above and beyond what is called for on the COI.
Condition: Unknown
Due 26 October 2001
Resolved 26 October 2001
Navigation
Issued 16 August 2000 Resolved
Paint both port and starboard running light side shields mat black.
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Fire Fighting
Issued 16 August 2000 Resolved
Provide metallic fire nozzle IAW 46 CFR 181.15-10(e) prior to 22AUG00.
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Documentation
Issued 16 August 2000 Resolved
Provide valid FCC Telephony Certificate prior to 22AUG00.
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Construction/Loadline
Issued 16 August 2000 Resolved
Provide both visual and audible bilge high level alarms at the vessels operating station prior to 22AUG00.
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Lifesaving
Issued 16 August 2000 Resolved
Properly install weak links and sea painters for both life floats.
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Unknown
Issued 1 November 1999 Resolved
Submit plans for modifications to forward cabin.
Condition: Unknown
Due 19 November 1999
Resolved 19 November 1999
Lifesaving
Issued 1 November 1999 Resolved
Provide two-painter arrangement for life floats with weak link prior to carrying passengers.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Documentation
Issued 1 November 1999 Resolved
After completing modifications to vessel and installing ballast make vesselready and conduct and incline experiment/test of vessel to the satisfactionof the attending marine inspector.
Condition: Unknown
Due 19 November 1999
Resolved 19 November 1999
Documentation
Issued 1 November 1999 Resolved
Prior to carrying passengers provide valid stability letter.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Construction/Loadline
Issued 1 November 1999 Resolved
Repair approximate 1 quart/minute leak in hull above shaft log at reverse bend starboard side prior to carrying passengers._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Engineering
Issued 29 March 1999 Resolved
Replace existing PVC piping on engine driven aux. generator raw water system with approved mettalic piping, hoses, and fittings.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Engineering
Issued 29 March 1999 Resolved
Replace existing PVC piping on propulsion engine with approved mettalic piping, hoses, and fittings.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Deck/Cargo
Issued 29 March 1999 Resolved
Make repairs to ships rigging system in accordance with riggers report.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Fire Fighting
Issued 29 March 1999 Resolved
Submit plans and install fixed firefighting system in engine room in accordance with 46 CFR 181.410.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 29 March 1999 Resolved
In the attedance of the attending Marine Inspector conduct underway checkride.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Documentation
Issued 29 March 1999 Resolved
Provide proof of a valid approved drug testing program.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 29 March 1999 Resolved
Remove and replace as nessecary all frame to floor bolts.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 29 March 1999 Resolved
Remove and replace as nessecary all frame to keel bolts.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Engineering
Issued 29 March 1999 Resolved
Permanently mount reduction gear oil cooler and renew all associated hose with Coast Guard approved hose and fittings.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Deck/Cargo
Issued 29 March 1999 Resolved
Make permanent repairs to ships anchor winch and prove operation.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 29 March 1999 Resolved
Remove all gear as nessecary to make internal hull avilable for inspection.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Electrical
Issued 29 March 1999 Resolved
Submit plans for and completly rewire battery charger.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Deck/Cargo
Issued 29 March 1999 Resolved
Make area under main chain plates accessible for inspection.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Engineering
Issued 29 March 1999 Resolved
Make all fuel and water tanks accesible for inspection.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Accommodation/Occupational Safety
Issued 29 March 1999 Resolved
Connect forward toilet to a approved MSD device or remove toilet from service.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Navigation
Issued 29 March 1999 Resolved
Make nessecary repair to correct slop in vessels steering system.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Deck/Cargo
Issued 29 March 1999 Resolved
Supply a detail list of problems and proposed solutions for ships sails andrigging.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Fire Fighting
Issued 29 March 1999 Resolved
Have portable fire extinguishers serviced.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 29 March 1999 Resolved
Submit plans and install bilge alarms IAW 46 CFR 182.530.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 29 March 1999 Resolved
Remove existing PVC piping in ships bilge pumping system and replace with approved mettalic piping.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 29 March 1999 Resolved
Replace keel.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 29 March 1999 Resolved
Replace all keel bolts.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 29 March 1999 Resolved
Refasten the gardboard plank and all plank butts.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 29 March 1999 Resolved
Repair/replace loose plank 5 stbd. 15 feet aft of bow.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 29 March 1999 Resolved
Reinstall ballast in original location.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Engineering
Issued 29 March 1999 Resolved
Find where diesel leak forward is coming from and correct.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Lifesaving
Issued 29 March 1999 Resolved
Install on vessel and make avilable for inspection all lifesaving appliances.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Electrical
Issued 29 March 1999 Resolved
Bring vessels electrical system up to code as per 46 CFR.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Electrical
Issued 29 March 1999 Resolved
Repair or completly remove from vessels electrical system the belt driven aux generator.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 29 March 1999 Resolved
Completly recaulk entire vessel.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 14 May 1996 Resolved
Repair broken taft rail.
Condition: Unknown
Due 24 May 1996
Resolved 24 May 1996
Lifesaving
Issued 14 May 1996 Resolved
Properly stencil both lifefloats.
Condition: Unknown
Due 24 May 1996
Resolved 24 May 1996
Lifesaving
Issued 3 June 1994 Resolved
LABEL AREA COVER FOR LIFE JACKET STORAGE IN LIFE BOAT.
Condition: Unknown
Due 16 June 1994
Resolved 13 July 1994
Navigation
Issued 3 June 1994 Resolved
PROVIDE UPDATED CHARTS AND LIGHT LIST.
Condition: Unknown
Due 16 June 1994
Resolved 13 July 1994
Lifesaving
Issued 3 June 1994 Resolved
REPAIR COVER COATING OF LIFEFLOATS.
Condition: Unknown
Due 16 June 1994
Resolved 13 July 1994
Lifesaving
Issued 3 June 1994 Resolved
MAKE LIFE FLOATS SO THEY FLOAT FREE._x001C_
Condition: Unknown
Due 16 June 1994
Resolved 13 July 1994
Navigation
Issued 10 June 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Lifesaving
Issued 11 June 1992 Resolved
STENCIL RING BUOY WITH VESSEL'S NAME.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Accommodation/Occupational Safety
Issued 11 June 1992 Resolved
LABEL FORWARD EMERGENCY EXIT.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Construction/Loadline
Issued 11 June 1992 Resolved
REATTACH HANDLE TO ENGINE COOLING THRU-HULL FITTING SHUT-OFF VALVE.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Deck/Cargo
Issued 11 June 1992 Resolved
PROVE PROPER OPERATION OF THE WINDLASS AND THE WINCH.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Electrical
Issued 11 June 1992 Resolved
PROVIDE AMP METER FOR AC GENERATOR.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Electrical
Issued 11 June 1992 Resolved
REMOVE EXTENSION CORDS FROM ENGINE ROOM.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Fire Fighting
Issued 11 June 1992 Resolved
PROVIDE SUCTION HOSE FOR HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Lifesaving
Issued 11 June 1992 Resolved
LABEL THE LIFEJACKET STOWAGE LOCKER IN THE CABIN.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Electrical
Issued 11 June 1992 Resolved
BY-PASS THE TOGGLE SWITCH FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Navigation
Issued 11 June 1992 Resolved
MAKE CORRECTION TO CHARTS FOR AREA OF OPERATIONS AND PUBS AS NEEDED.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Deck/Cargo
Issued 15 June 1990 Resolved
PROVE PROPER OPERATION OF ANCHOR WINDLASS.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Lifesaving
Issued 7 June 1989 Resolved
PROVIDE VESSEL WITH 4 ADULT AND 3 CHILD-SIZE PFD'S IAW 46 CFR 180.25-5(A).
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Accommodation/Occupational Safety
Issued 7 June 1989 Resolved
PROVIDE HANDLE FOR SEA VALVE BELOW GALLEY SINK.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Engineering
Issued 7 June 1989 Resolved
PROVE PROPER OPERATION OF REMOTE FUEL SHUT-OFF AT FUEL TANK IAW 46 CFR 182.20-40(B)(3).
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Fire Fighting
Issued 16 March 1988 Resolved
SERVICE TWO FIRE EXTINGUISHERS: ONE OUTDATED, ONE PARTIALLY DISCHARGED OR LEAKING.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Engineering
Issued 16 March 1988 Resolved
ENSURE FWD FUEL TANKS ARE PERMANENTLY DISCONNECTED FROM FUEL SYSTEM AND USED ONLY FOR WATER BALLAST. GAS FREE AND THOROUGHLY VENT TANKS, IF LEFT EMPTY AFTER FUEL REMOVED. (SEE 46 CFR 182-35.1 AND 132.20-30(B)).
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Engineering
Issued 16 March 1988 Resolved
REPLACE PLASTIC FUEL OIL GAGE TUBE AND MANUAL VALVES WITH EITHER A MARINE TYPE FUEL GAGE ENTERING THE TANK FROM THE TOP, OR A TEMPERED GLASS TUBE, METAL GUARD AND SPRING-LOADED VALVES WHICH ARE CLOSED EXCEPT WHILE BEING HELD OPEN. SEE 46 CFR 182.20-25(A).
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Construction/Loadline
Issued 16 March 1988 Resolved
MAKE ENGINE AND AFT FUEL TANK COMPARTMENTS FUMETIGHT FROM ACCOMMODATIONS. (SEE 46 CFR 182.35-1).
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Documentation
Issued 22 June 1987 Resolved
CHANGE MARINE DOCUMENT SERVICE TO INCLUDE COASTWISE TRADE.
Condition: Unknown
Due 22 June 1987
Resolved 22 June 1987
Electrical
Issued 22 June 1987 Resolved
INSTALL PROTECTIVE GUARD FOR GENERATOR PULLEY.
Condition: Unknown
Due 22 June 1987
Resolved 22 June 1987
Electrical
Issued 22 June 1987 Resolved
REMOVE OR COVER LIGHT FIXTURE OUTBOARD GENERATOR.
Condition: Unknown
Due 22 June 1987
Resolved 22 June 1987
Engineering
Issued 6 October 1986 Resolved
REPLACE TAILSHAFT RUBBER CUTLASS BEARING.
Condition: Unknown
Due 6 October 1986
Resolved 6 October 1986
Construction/Loadline
Issued 6 October 1986 Resolved
REPAIR KEEL WOODWORK IN MARKED AREAS (3) OF THE KEEL AND WORMSHOE.
Condition: Unknown
Due 6 October 1986
Resolved 6 October 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.