Records from 1985 to 2006. Most recent: inspection, 11 July 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
11 July 2006
NPV Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2710980
24 January 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 286415
20 January 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 273867
4 November 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 409998
27 March 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 654681
21 March 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 402027
8 September 1996
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 767618
5 August 1996
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 195124
12 November 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 362206
23 May 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 646015
14 May 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 81467
24 February 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 654672
23 February 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 654671
4 February 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 348643
28 January 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 348506
10 December 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 681127
31 October 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 346914
16 October 1990
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 339837
11 April 1990
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 336427
7 March 1989
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 328902
21 November 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 313213
16 September 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 304784
23 May 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 302390
14 May 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 302358
Lifesaving › Launching Appliances › Release Mechanism
Issued 11 July 2006
No resolution recorded
Hydrostatic release for EPIRB expired.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 July 2006
No resolution recorded
Wiring for fish hold's water pump located STBD located port side in engine room installed with only temporary insulation.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 11 July 2006
No resolution recorded
Wiring for emergency fire lantern located port side in engine room installed with only temporary insullation.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 11 July 2006
No resolution recorded
NTVRP - Non Tank Vessel Response Plan not available.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Unknown
Issued 21 March 1997
Resolved
Vessel burns all garbage (paper, food waste, plastics) in a barrel and disposes burned waste overboard at highseas._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 2000
Resolved 23 January 2000
Documentation
Issued 4 February 1992
Resolved
BOARDING OFFICER ASKED THE CAPTION FOR A COPY OF THE VESSEL'S GARBAGE PLAN.CAPTAIN STATED THAT THERE WAS NOT ONE ON BOARD
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Documentation
Issued 28 January 1992
Resolved
THE COFR ESPIRATION DATE IS 21NOV91. MARITIME AGENCIES OF THE PACIFIC LT.(MAPSHIP) WILL BE CALLING D.C. FOR A TEMP. NO.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Lifesaving
Issued 31 October 1991
Resolved
BOARDING OFFICER EXAMINED PERSONAL FLOATATION DEVICES AND NOTED THAT THEY WERE MISSING THE REQUIRED RETROREFLECTIVE TAPE.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Lifesaving
Issued 31 October 1991
Resolved
BOARDING OFFICERS EXAMINED PERSONAL FLOATATION DEVICES AND NOTED THAT THE REQUIRED LIGHTS WERE MISSING.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Documentation
Issued 7 March 1989
Resolved
VESSEL DID NOT HAVE OIL TRANSFER PROCEDURES AS REQUIRED BY 33 CFR 155.720.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Deck/Cargo
Issued 16 September 1985
Resolved
OIL SLUDGE TANK OF INADEQUATE CAPACITY, A VIOLATION OF 33 CFR 155.370(A).
Condition: Unknown
Due 16 September 1985
Resolved 16 September 1985
Documentation
Issued 14 May 1985
Resolved
VESSEL OIL TRANSFER PROCEDURES CONTENTS ARE NOT SATISFACTORY A VIOLATION OF33 CFR 155.730 AND 155.750
Condition: Unknown
Due 16 September 1985
Resolved 14 May 1985
Documentation
Issued 14 May 1985
Resolved
OIL RECORD BOOK (NEW EDITION)WAS NOT AVAIABLE ON BOARD VESSEL HAD THE OIL D.O.T. EDITTION ONBOARD BUT IT WAS NEVER PROPERLY KEPT 33 CFR 155.125.(J)
Condition: Unknown
Due 16 May 1985
Resolved 14 May 1985
Engineering
Issued 14 May 1985
Resolved
NO FUEL OIL DISCHARGE CONTAINMENT AVAILABLE ABOARD FOR THE FUEL OIL FILL LINE,A,VIOLATION OF 33 CFR 155.320(A)(1)
Condition: Unknown
Due 16 September 1985
Resolved 14 May 1985
Documentation
Issued 14 May 1985
Resolved
SOLAS RADIOTELEGRAPHY CERTIFICATE EXPIRED 13 FEB 85
Condition: Unknown
Due 16 September 1985
Resolved 14 May 1985
Engineering
Issued 14 May 1985
Resolved
NO APPROVED OILY WATER SEPARATING AND MORITOR SYSTEM AVAILABLE ON BOARD THEVESSEL. NEW VESSEL BUILT 1980 A VIOLATION OF 33 CFR 155.380(A)
Condition: Unknown
Due 16 September 1985
Resolved 14 May 1985
Engineering
Issued 14 May 1985
Resolved
NO STANDARD DISCHARGE CONNECTIONS A VIOLATION OF 33 CFR 155.430
Condition: Unknown
Due 16 September 1985
Resolved 14 May 1985