MAURY USCG vessel records Sign in
← All vessels

TRINITY IV

TRINITY IV is a 1980 offshore supply vessel. The Coast Guard has recorded 41 inspections since 1990, most recently in August 2014, along with 24 deficiencies and 1 casualty investigation in 2013.

Records from 1990 to 2014. Most recent: inspection, 18 August 2014.

Built
1980
Last inspected
18 August 2014
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8767379 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDF3143
193011
Flag
UNITED STATES
366817870, 367436420 (licence lapsed)
Maury page id
psix-193011

Inspections, by type

…with no type recorded10
Years with a record 20 calendar years (1990–2014)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)72.9 ft × 36.0 ft × 6.8 ft
Registered tonnagegross 177 / net 120
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCROWN POINT INDUSTRIES IN · JEAN LAFITTE, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it120 - Regulatory (Subpart C or D), Net Ton
177 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF3143MMSI 367436420 · expired · compulsorily equipped · granted 13 January 2010, cancelled 14 March 2020
WDA5230MMSI 366817870 · cancelled · compulsorily equipped · granted 6 July 2001, cancelled 25 November 2009 · licensed under a name not among this hull’s recorded names (not shown)
WCV8462MMSI not assigned · expired · compulsorily equipped · granted 7 July 1997, cancelled 1 April 2006 · licensed under a name not among this hull’s recorded names (not shown)
WAL9967MMSI not assigned · expired · compulsorily equipped · granted 28 March 1995, cancelled 6 August 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 41

18 August 2014 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4958827
8 August 2014 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4958824
9 December 2010 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3907542
25 March 2010 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3704609
1 February 2007 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2865411
12 January 2007 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2854833
9 June 2006 Examination of Repairs · Re-Inspection · Ballast Water Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2679777
25 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2658781
18 January 2006 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2568905
22 February 2005 Examination of Repairs · Hull Examination · Ballast Water Examination · COI Inspection · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2296710
21 December 2004 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2262943
29 January 2004 Re-Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1998760
18 February 2003 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1744841
26 June 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1636938
26 June 2001 Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1067541
21 June 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 13840
16 May 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462959
11 February 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404904
17 August 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778165
15 June 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393179
4 May 1998 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364730
26 April 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 789420
3 July 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407916
27 February 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762395
14 February 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 191067
27 March 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405880
6 June 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 758140
19 May 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 195050
24 February 1995 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1420944
21 November 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 185924
20 May 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1169552
28 February 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438152
14 May 1993 Inclining Experiment · Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432680
28 August 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 960799
25 June 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265017
25 June 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265061
23 June 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 950128
21 April 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405316
4 April 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234469
28 September 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919189
25 April 1990 Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1240010

Deficiency record · 24

Electrical › Electric Generation Source (service) › Conductor
Issued 18 August 2014 Resolved
Due to engine room fire, several electrical cables were melted rendering the port engine room inoperable. Temp repairs to be made sufficiently to allow vessel to safely transit to New Iberia.
Action required: 705 - Other - as specified
Resolved 22 August 2014
Resolution: Temp repairs have been made and vessel has been issued a PTP,
Lifesaving › Rescue Boat › Hull (rigid)
Issued 9 December 2010 Resolved
Company replaced existing rescue boat with an unapproved Zodiac Cadet 340 white in color boat. Lifting eyes in the Zodiac 340 are not approved for lifting with personnel onboard the vsl. Company is currently researching a solution.
Action required: 705 - Other - as specified
Due 9 January 2011
Resolved 30 November 2011
Resolution: Completed rescue boat overload test of two times the B weight. all sat.
Stability › Incline Test › General
Issued 25 March 2010 Resolved
Evaluate vessel modifications and compare to original lightship values. If cumulative changes are in excess of 2% of original lightship value. Prepare vessel for new deadweight survey.
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 2 December 2011
Resolution: Vessel completed deadweight survey on 2 Dec 11. Survey has been submitted to MSC for review. Issued new 835 reducing deck cargo until MSC has completed the review. See documents for completed survey.
Engineering › Fuel Oil Service System › Piping
Issued 9 June 2006 Resolved
Per NVIC 8-91 vsl hydraulic jacking system must substantially meet the requirement of 46 CFR 58.30 and 56.30.
Action required: 705 - Other - as specified
Due 9 June 2007
Resolved 24 August 2010
Resolution: Certification letter rcvd and attached to vessel file.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 26 June 2002 Resolved
FIRE SAFETY PLAN DOES NOT REFLECT EQUIPMENT CURRENTLY INSTALLED ON VESSEL, PROVIDE APPROVED PLAN ON BOARD TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Due 27 July 2002
Resolved 4 January 2005
Navigation › Piloting/Steering
Issued 26 June 2002 Resolved
REPAIR/ PROVIDE RUDDER ANGLE INDICATOR IN PILOTHOUSE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Due 27 July 2002
Resolved 25 March 2003
Lifesaving
Issued 15 June 1999 Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District's Policy "Rescue Boat Requirements on Offshore Supply Vessels" dated 12NOV98 to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Documentation
Issued 28 February 1994 Resolved
PROVIDE AND PLACE ON BOARD THE VESSEL A U. S. COAST GUARD APPROVED OPERATING MANUAL AND STABILITY LETTER.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Engineering
Issued 21 April 1992 Resolved
PROVE OPERATION OF OVERSPEED TRIPS ON BOTH MAIN ENGINES AND THE PORT GENERATOR.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Fire Fighting
Issued 21 April 1992 Resolved
PROVE PROPER OPERATION OF STBD ELECTRIC SUBMERSIBLE PUMP.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Documentation
Issued 28 September 1990 Resolved
PROVIDE RE-ADMEASUREMENT CERTIFICATE FOR ADDITION OF SPONSONS.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Documentation
Issued 28 September 1990 Resolved
PROVIDE DRAWINGS APPROVED BY COAST GUARD MARINE SAFETY CENTER FOR HULL MODIFICATIONS (SPONSONS) AND CRANE INSTALLIATION.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Documentation
Issued 25 April 1990 Resolved
SUBMIT STABILITY CALCULATIONS TO THE MARINE SAFETY CENTER FOR ISSUANCE OF ASTABILITY LETTER.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Engineering
Issued 25 April 1990 Resolved
PROVIDE ON BOARD FUEL OIL TANK SHUT OFF REACH RODS.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Accommodation/Occupational Safety
Issued 25 April 1990 Resolved
REPLACE VALVE ON STARBOARD AIR COMPRESSOR LINE TO 200 PSI OR HIGHER.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Documentation
Issued 25 April 1990 Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE, FIRE CONTROL PLAN AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Documentation
Issued 25 April 1990 Resolved
PROVIDE ON BOARD A ROUGH COPY OF OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Navigation
Issued 25 April 1990 Resolved
INSTALL RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Lifesaving
Issued 25 April 1990 Resolved
PROVIDE ON BOARD AN AUXILIARY LINE FOR LINE THROWING GUN.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Electrical
Issued 25 April 1990 Resolved
PROVIDE CRIMPED BATTERY CONNECTTIONS ON ALL THREE BATTERIES AND FUSED BUSS BAR TERMINAL FOR ALARM BATTERY
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Electrical
Issued 25 April 1990 Resolved
REPAIR OR REMOVE 12 VOLT ELECTRICAL LIGHTS IN PORT AND STARBOARD ENGINE ROOM.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Documentation
Issued 25 April 1990 Resolved
PROVIDE ON BOARD A FIRE CONTROL SAFETY PLAN.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Documentation
Issued 25 April 1990 Resolved
PROVIDE ON BOARD VALID FCC RADIO STATION LICENSE.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Documentation
Issued 25 April 1990 Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONSOF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990

Casualty record · 1

11 January 2013Routine · role: Involved in a Marine Casualty · activity 4523677
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.