MAURY USCG vessel records Sign in
← All vessels

MISS REBECCA

MISS REBECCA is a 1981 industrial vessel. The Coast Guard has recorded 54 inspections since 1985, most recently in October 2025, along with 71 deficiencies and 1 casualty investigation in 2006.

Records from 1985 to 2025. Most recent: inspection, 10 October 2025.

Built
1981
Last inspected
10 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC9118
193647
Flag
UNITED STATES
368372390
Maury page id
psix-193647

Inspections, by type

…with no type recorded15
Years with a record 26 calendar years (1985–2025)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)74.0 ft × 22.0 ft × 5.5 ft
Registered tonnagegross 58 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNICHOLS BOAT WORKS · HOOD RIVER, OR, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKODIAK, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 23 June 2026 · expires 30 June 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
43 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP6407MMSI 368372390 · active · voluntarily equipped · granted 8 June 2024, expires 8 June 2034 · licensed under a name not among this hull’s recorded names (not shown)
WDL6388MMSI 368150230 · cancelled · voluntarily equipped · granted 18 June 2020, cancelled 10 June 2024
WDC9118MMSI 367097820 · expired · voluntarily equipped · granted 8 March 2006, cancelled 14 May 2016
WYR5298MMSI not assigned · expired · voluntarily equipped · granted 13 March 1996, cancelled 18 March 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KOBUK RIVER Freight Barge · MISLE 252290 · 11 May 2007 · activity 2928107KOBUK RIVER Freight Barge · MISLE 252290 · 10 October 2006 · activity 2802643LILY Freight Barge · MISLE 43045 · 12 August 1998 · activity 45686

Inspection history · 54

10 October 2025 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8250645
14 July 2025 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8205738
15 May 2025 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8137133
17 June 2020 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7002378
8 May 2012 Administration
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4779859
11 May 2007 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2928107
10 October 2006 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2802643
24 May 2006 Administrative Inspection
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2673154
26 January 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2573667
25 January 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2573133
20 July 2005 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2433340
26 April 2005 MTSA/ISPS Verification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2386553
7 May 2004 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2073468
15 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1985865
20 May 2003 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1814084
22 July 2002 Administrative Inspection
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1650448
27 April 2001 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1468239
17 January 2001 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1057789
2 May 2000 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1395481
7 January 1999 Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1397044
1 October 1998 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 664069
12 August 1998 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 45686
5 August 1998 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 800279
29 April 1998 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1124367
21 January 1998 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1121025
2 December 1997 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1386135
10 January 1997 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1099614
10 December 1996 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1091264
15 November 1996 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 864313
17 November 1995 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 877331
17 January 1995 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1180576
28 February 1994 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1463071
22 December 1993 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1356475
15 March 1993 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1150785
27 January 1993 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1141377
13 November 1992 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 961054
9 May 1992 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 955178
28 February 1992 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 955806
10 December 1991 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 946401
2 December 1991 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 942164
6 March 1991 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 926914
9 May 1990 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1224418
2 March 1990 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 925168
16 February 1990 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1225092
15 December 1989 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 906685
10 June 1989 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 972654
28 March 1989 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 888601
14 April 1988 Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1199303
24 March 1988 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 990779
17 April 1987 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1309430
15 April 1987 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1013489
25 March 1987 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1001919
17 April 1986 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1307155
23 April 1985 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 980474

Deficiency record · 71

Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 20 May 2003 Resolved
Provide approval number for the Marine Sanitation Device.
Due 20 June 2003
Resolved 23 May 2003
Resolution: CG Approval number 159.015/2701/0 provided.
Fire Fighting › Remote Fuel Shutoff
Issued 20 May 2003 Resolved
Lable name and direction of operation of the remote fuel valve shutoff.
Due 20 June 2003
Resolved 23 May 2003
Resolution: Remote fuel valve shutoff labled.
Documentation
Issued 2 May 2000 Resolved
PROVIDE VALID ORIGINAL CERTIFICATE OF DOCUMENTATION ON BOARD.
Condition: Unknown
Due 26 May 2000
Resolved 22 June 2000
Deck/Cargo
Issued 2 May 2000 Resolved
PROVIDE EVIDENCE OF ANNUAL CRANE CERTIFICATION.
Condition: Unknown
Due 26 May 2000
Resolved 22 June 2000
Navigation
Issued 2 May 2000 Resolved
REPLACE ENTIRE LOWER MASTHEAD LIGHT FIXTURE.
Condition: Unknown
Due 26 May 2000
Resolved 22 June 2000
Engineering
Issued 2 May 2000 Resolved
FREE-UP AND RE-LABEL EMERGENCY FUEL SHUT OFFS.
Condition: Unknown
Due 26 May 2000
Resolved 22 June 2000
Lifesaving
Issued 2 May 2000 Resolved
PROVIDE ON BOARD AND PROPERLY INSTALL LIFERAFT.
Condition: Unknown
Due 26 May 2000
Resolved 22 June 2000
Lifesaving
Issued 2 May 2000 Resolved
REPLACE OUT OF DATE HAMMAR RELEASES FOR BOTH LIFERAFT AND EPIRB.
Condition: Unknown
Due 26 May 2000
Resolved 22 June 2000
Documentation
Issued 7 January 1999 Resolved
PROVIDE PROOF OF ENROLLEMENT IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Electrical
Issued 7 January 1999 Resolved
PROVIDE EXHAUST BLANKETS ON EXHAUST OF VESSEL GENERATORS.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Accommodation/Occupational Safety
Issued 7 January 1999 Resolved
LABEL EMERGENCY ESCAPE FROM ENGINEROOM.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Engineering
Issued 7 January 1999 Resolved
RENEW PORT, STBD AND CENTERLINE PROPULSION SHAFTS AND STRUT BEARINGS.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Fire Fighting
Issued 7 January 1999 Resolved
PROVIDE SERVICING REPORTS AND PROVIDE PROPER SERVICING OF VESSEL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Construction/Loadline
Issued 7 January 1999 Resolved
GRIND OUT AND WELD 3 CRACKED WELDS IN WAY OF OVERHEAD STIFFENERS IN STBD FWD VOID AT OVERHEAD ON STIFFENERS #3, #4, #5.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Accommodation/Occupational Safety
Issued 29 April 1998 Resolved
REMOVE AIR COMPRESSOR FROM BLOCKING ENGINE ROOM ESCAPE ON PORT SIDE AND RELOCATE.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Engineering
Issued 2 December 1997 Resolved
PROVIDE/INSTALL 100 PSI RELIEF VALVE FOR WATER HEATER.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 2 December 1997 Resolved
LABEL SURVIVAL SUIT LOCKER.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Documentation
Issued 2 December 1997 Resolved
PROVIDE STABILITY BOOKLET ON BOARD.
Condition: Unknown
Due 2 December 1997
Resolved 4 December 1997
Fire Fighting
Issued 2 December 1997 Resolved
MARK FIRE AXE WITH VESSEL NAME.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 2 December 1997 Resolved
REPAIR/REPLACE BILGE ALARM IN LAZARETTE.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 2 December 1997 Resolved
HAVE LIFERAFT SERVICED.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 2 December 1997 Resolved
REPLACE OUT-DATED LIFERAFT HYDROSTAT RELEASE.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Accommodation/Occupational Safety
Issued 2 December 1997 Resolved
FREE UP ALL DOGS ON BOTH WATERTIGHT DOORS.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 2 December 1997 Resolved
PROVIDE ONE ADDITIONAL RING BUOY WITH BRACKET STBD SIDE MAIN DECK.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Accommodation/Occupational Safety
Issued 2 December 1997 Resolved
REMOVE AIR COMPRESSOR FROM MEANS OF ESCAPE IN ENGINE ROOM.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 2 December 1997 Resolved
EITHER PROVE THAT 121.5 MHZ EPIRB WAS MANUFACTURED AFTER 01OCT88 OR PROVIDE406MHZ EPIRB ON BOARD.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Documentation
Issued 10 December 1996 Resolved
PROVIDE CURRENT FCC LICENSE.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Documentation
Issued 10 December 1996 Resolved
PROVIDE ORIGINAL CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Lifesaving
Issued 10 December 1996 Resolved
PROVIDE PROPERLY SERVICED LIFERAFT ON VESSEL.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Lifesaving
Issued 10 December 1996 Resolved
MOUNT LIFERAFT IN FLOAT FREE ARRANGEMENT.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Accommodation/Occupational Safety
Issued 10 December 1996 Resolved
PROVIDE 100 PSI OR LESS RELIEF VALVE ON HOT WATER TANK TO REPLACE 150 PSI RELIEF VALVE OR OPEN TANK FOR INSPECTION.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Lifesaving
Issued 10 December 1996 Resolved
PROVIDE THREE ADDITIONAL RED FLARE DISTRESS SIGNALS.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Lifesaving
Issued 10 December 1996 Resolved
PROVE OPERATION OF LIGHT ATTACHED TO IMMERSION SUIT.
Condition: Unknown
Due 10 December 1996
Resolved 11 December 1996
Lifesaving
Issued 10 December 1996 Resolved
PROVE OPERATION OF RING BUOY WATERLIGHT.
Condition: Unknown
Due 10 December 1996
Resolved 11 December 1996
Construction/Loadline
Issued 10 December 1996 Resolved
PROVE PROPER OPERATION OF ALL DOGS ON STARBOARD WATERTIGHT DOOR ON MAIN DECK LEADING TO ENGINE ROOM.
Condition: Unknown
Due 10 December 1996
Resolved 11 December 1996
Lifesaving
Issued 10 December 1996 Resolved
UNTIE EPIRB FROM VESSEL AND MAINTAIN IN FLOAT FREE ARRANGEMENT.
Condition: Unknown
Due 10 December 1996
Resolved 11 December 1996
Engineering
Issued 15 November 1996 Resolved
REPLACE PORT SHAFT BEARING TO CORRECT EXCESSIVE MOVEMENT OF PORT SHAFT.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Construction/Loadline
Issued 15 November 1996 Resolved
OPEN, VENTILATE AND PREPARE FOR INTERNAL EXAM BOTH FORWARD VOIDS.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Engineering
Issued 15 November 1996 Resolved
REPLACE STARBOARD SHAFT BEARING TO CORRECT EXCESSIVE MOVEMENT OF STARBOARD SHAFT.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Engineering
Issued 15 November 1996 Resolved
REPAIR DENT OR REPLACE STARBOARD PROPELLER.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Construction/Loadline
Issued 15 November 1996 Resolved
REPAIR CRACKED VERTICAL STIFFENER ON PORT SIDE IN LAZARETTE.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Lifesaving
Issued 17 January 1995 Resolved
Replace grab line on ring buoy mounted on port side of pilothouse.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Electrical
Issued 17 January 1995 Resolved
Provide lightbulb for emergency light in engineroom on starboard side.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Construction/Loadline
Issued 17 January 1995 Resolved
Repair bilge alarm in engineroom.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Engineering
Issued 17 January 1995 Resolved
Repair exhaust leak on auxiliary generator at exhaust pipe stop valve in engine room.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Documentation
Issued 17 January 1995 Resolved
Provide FCC operators permit for SSB AM radio.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Lifesaving
Issued 17 January 1995 Resolved
Provide operable light for each survival suit.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Documentation
Issued 17 January 1995 Resolved
Provide Certificate of Documentation renewal sticker.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Lifesaving
Issued 17 January 1995 Resolved
Provide evidence of drug testing program.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Lifesaving
Issued 17 January 1995 Resolved
Vessel is restricted from operating pending completion of these items.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Electrical
Issued 17 January 1995 Resolved
Provide proper electrical wiring system for Jabsco bilge pump in engine room starboard side forward.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Construction/Loadline
Issued 17 January 1995 Resolved
Make rounds to check water levels in engine room bilges every 15 minutes while vessel is underway until bilge alarm, is repaired.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Engineering
Issued 17 January 1995 Resolved
Replace sightglass on fuel day tank in engine room.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Engineering
Issued 17 January 1995 Resolved
Re-mark emergency fuel shutoffs.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Electrical
Issued 17 January 1995 Resolved
Make all electrical connections and terminal boxes for Jabsco submersible pumps in engine room bilges watertight.
Condition: Unknown
Due 17 January 1995
Resolved 17 January 1995
Construction/Loadline
Issued 22 December 1993 Resolved
FREE-UP ALL WATERTIGHT DOORS ON MAIN DECK.
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Lifesaving
Issued 22 December 1993 Resolved
SERVICE OR REPLACE LIFERAFT HYDROSTATIC RELEASE.
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Deck/Cargo
Issued 10 December 1991 Resolved
SUPPLY TEST WEIGHT AND PROVE OPERATION OF DECK CRANE. TEST TO BE PERFORMEDPRIOR TO USE FOR CARGO AND NOT LATER THAN THE DATE OF COMPLIANCE.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Construction/Loadline
Issued 10 December 1991 Resolved
REMOVE EXCESS OIL FROM BILGES OF ENGINE ROOM AND REMOVE OLD ABSORBENT PADS FROM BILGES. THIS ITEM TO COMPLETED PRIOR TO VESSEL OPERATING AND NOT LATER THAN DATE OF COMPLIANCE.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Lifesaving
Issued 6 March 1991 Resolved
Vessel restricted to operating in Kachemak Bay until life raft serviced. (last service 02/90).
Condition: Unknown
Due 6 March 1991
Resolved 6 March 1991
Electrical
Issued 15 December 1989 Resolved
PROVE THE PROPER OPERATION OF BOTH GENERATOR OVERSPEED TRIPS.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Engineering
Issued 15 December 1989 Resolved
INSTALL AND PROVE THE PROPER OPERATION OF VISUAL/AUDIBLE ALARMS FOR MAIN ENGINES AND BOTH GENERATORS.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Engineering
Issued 15 December 1989 Resolved
ON THE BRIDGE, REPLACE THE OIL PRESSURE GAUGE FOR THE STBD MAIN ENGINE.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Documentation
Issued 15 December 1989 Resolved
PROVIDE OIL TRANSFER PROCEDURES WITH ONE LINE DIAGRAM.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Fire Fighting
Issued 15 December 1989 Resolved
REPLACE THE GUAGE ON THE DISCHARGE SIDE OF THE FIRE PUMP.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Construction/Loadline
Issued 15 December 1989 Resolved
MARK THE 5 FT DRAFT ON THE VESSEL FWD AND AFT PORT AND STBD.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Construction/Loadline
Issued 15 December 1989 Resolved
PROVIDE CAPACITY TABLE FOR THE CRANE AND TEST THE CRANE AT 1.1 X SWL.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Engineering
Issued 28 March 1989 Resolved
PROVIDE GUARDS FOR THE RACOR FILTERS ON THE FUEL SYSTEMS.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Engineering
Issued 28 March 1989 Resolved
PROVIDE GUARDS FOR ALL EXPOSED PULLEYS AND BELTS ON VARIOUS PIECES OF EQUIPMENT IN THE ENGINE ROOM.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Construction/Loadline
Issued 28 March 1989 Resolved
CROP AND RENEW METAL IN WAY OF DAMAGE AT THE CHINE IN #1 STBD FUEL TANK.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Navigation
Issued 28 March 1989 Resolved
DISASSEMBLE STEERING ASSEMBLY TO FACILITATE INSPECTION OF THE CONNECTING PINS.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989

Casualty record · 1

10 October 2006Routine · role: Involved in a Marine Casualty · activity 2802643
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

TWI-LITE (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record