ELIZABETH ANN

ELIZABETH ANN is a 1980 towing vessel. The Coast Guard has recorded 20 inspections since 1998, most recently in July 2026, along with 20 deficiencies and 1 casualty investigation in 2016.

Records from 1998 to 2026. Most recent: inspection, 23 July 2026.

Built
1980
Last inspected
23 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WUU6350
194011
Flag
UNITED STATES
Maury page id
psix-194011

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

…with no type recorded8
Years with a record 15 calendar years (1998–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)57.1 ft × 24.0 ft × 7.0 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBATON ROUGE MARINE REPAIR · PLAQUEMINE POINT, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMUSKOGEE, OK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 December 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Net Ton
90 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 20

23 July 2026 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8447777
5 August 2025 Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8204448
21 August 2024 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7985444
14 September 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7790802
28 June 2022 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7488651
8 September 2021 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7309113
13 July 2020 COI Inspection · Deficiency Check · Initial Certification · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6984884
8 June 2018 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6456449
30 January 2018 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6346480
24 February 2016 Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5834711
12 March 2010 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3702800
11 January 2010 Industry Initiated Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3663722
8 January 2009 Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3391234
14 June 2001 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 212659
12 July 2000 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 212726
14 July 1999 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 212023
17 August 1998 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 213730
12 August 1998 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 419471
17 April 1998 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 415011
21 February 1998 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 413048

Deficiency record · 20

09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 September 2023 Resolved
Vessel's propulsion shafts (Port/STBD) are exposed increasing the risk to personnel working near the rotating machinery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 21 September 2023
Resolution: Metal guards were installed around the exposed portions of the propulsion shafts. Pictures received via email on 21SEP2023.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 September 2023 Resolved
Vessel's eye wash solution was not of a suitable volume for the types of incidents crewmembers may be involve in.
Action required: 705 - Other - as specified
Due 21 September 2023
Resolved 28 September 2023
Resolution: Owner provided pictures via email of the eye wash station of an appropriate size installed onbaord the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 June 2022 Resolved
The remote pull station located within the wheelhouse was pulled for testing and was not able to be reset. The fire detection panel continued to alarm.
Action required: 705 - Other - as specified
Due 1 July 2022
Resolved 29 June 2022
Resolution: Photo provided via email showed new pullstation installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 June 2022 Resolved
The fire nozzle was only able to provide a solid stream and not able to produce a spray pattern.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 29 June 2022
Resolution: Photo provided via email shows new variable spray nozzle installed on fire hose.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 8 September 2021 Resolved
Magnetis Compass on board was unable to be illimunated. Vessel Owener shall ensure that the magnetic is is ablte to be illuminated during times of limited visibility in the wheel house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2021
Resolved 28 September 2021
Resolution: Installed a magnetic compass and wired in lighting option.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 September 2021 Resolved
Vessel owner was unable to provide a copy of the currewnt light list during the inspection. Owner shall ensure a current light list is kept on board the vessel at all times during operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2021
Resolved 28 September 2021
Resolution: A current copy of the light list was printed out and made available within the wheelhouse.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2021 Resolved
Vessel only had two Type I PFD's onboard the vessel during the inspection. COI requires 8 PFD's while the vessel is operation. Owner shall ensure the amount of Type I PFD's meets the requirements on the COI with in 7 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: Company rep has provided 08 fully outifitted type I PFD's onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 September 2021 Resolved
The two self ingiting lights attached to the ring bouys on board were using non approved 6V batteries. Owner shall ensure that the batterries used in the lights are apporved for the service intent.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: Company installed the correct battery type on both life ring lights and installed wiring to the battery post correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2020 Resolved
Properly label and outfit Life Jackets
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Life Jackets were properly labeled and outfited with lights and whistles.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 July 2020 Resolved
Repair port MDE emergency fuel shutoff
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Port MDE emergency fuel shutoff handle repaired.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 13 July 2020 Resolved
Post oil discharge and garbage placards
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Oil discharge and garbage placards posted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 July 2020 Resolved
Inspect fire extinguishers
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Fire extinguishers inspected.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 July 2020 Resolved
Label outside of life jacket storage compartment on bridge
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Life jacket storage compartment labeled.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 13 July 2020 Resolved
Insltall compass or swing meter
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 14 September 2020
Resolution: Compass installed.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 January 2009 Resolved
Excesive leaking. Repack shaft seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 8 June 2018
Resolution: Vessel repaired in dry dock.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 8 January 2009 Resolved
Missing service tags on all portable extinguishers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 9 January 2009
Resolution: Proof of service provided to MI
Electrical
Issued 21 February 1998 Resolved
46 C.F.R. 35.30-30 Exposed electrical outlets in pilot house.
Condition: Unknown
Action required: 10 - Deficiency Rectified
Due 21 March 1998
Resolved 8 June 2018
Resolution: Vessel repaired in dry dock.
Documentation
Issued 21 February 1998 Resolved
33 C.F.R. 164.72(a)(3) Missing restriced radio operator's license.
Condition: Unknown
Action required: 10 - Deficiency Rectified
Due 21 March 1998
Resolved 8 June 2018
Resolution: Vessel repaired in dry dock.
Documentation
Issued 21 February 1998 Resolved
33 C.F.R.164.72 (a)(3) Two radios installed, only one was operational.
Condition: Unknown
Action required: 10 - Deficiency Rectified
Due 21 March 1998
Resolved 8 June 2018
Resolution: Vessel repaired in dry dock.
Lifesaving
Issued 21 February 1998 Resolved
Missing handle for sound producing device, making it inoperable to produce any sound.
Condition: Unknown
Action required: 10 - Deficiency Rectified
Due 21 March 1998
Resolved 8 June 2018
Resolution: Vessel repaired in dry dock.

Casualty record · 1

24 February 2016Routine · role: Acknowledged Pollution Source · activity 5834711
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.