Records from 1993 to 2024. Most recent: inspection, 2 April 2024.
Documentation record
Registered dimensions (L × B × D)130.1 ft × 34.1 ft × 6.5 ft
Registered tonnagegross 241 / net 241
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDOUGLAS MARINE SERVICE, INC. · BALDWIN, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it241 - Regulatory (Subpart C or D), Net Ton
241 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 45
2 April 2024
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7888788
6 February 2024
Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7861292
26 January 2023
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7627712
10 February 2022
Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7394424
6 July 2021
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7264314
17 February 2021
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7141971
13 January 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6888702
7 January 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6606496
27 February 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6362692
21 November 2016
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6045175
18 February 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5817366
10 April 2015
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5100468
18 December 2013
Internal Structural Exam · COI Inspection · Cargo Tank Internal · Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4771151
29 June 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4360741
24 May 2012
Examination of Repairs · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4320932
6 March 2012
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4257905
19 August 2011
Administrative Inspection · COI Inspection · MTSA Verification · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4120706
15 June 2010
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3767176
10 July 2009
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3530202
11 June 2009
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3501402
4 March 2009
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3427818
28 October 2008
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3353037
26 August 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3309351
31 August 2007
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3043980
9 August 2006
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2741592
30 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2504748
31 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2480334
17 August 2005
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2465206
14 June 2005
MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2390645
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999931
26 August 2003
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1887770
18 July 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1647915
7 August 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457980
13 September 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397496
11 August 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393208
24 March 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778288
10 November 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467560
28 August 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1120167
11 August 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1117408
11 August 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390588
12 July 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374676
30 August 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 883160
11 August 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419478
12 September 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429938
25 August 1993
Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395976
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 February 2024
No resolution recorded
While MI was chipping rust the bottom hull plating was pierced due to lack of good steel. Approximately a half inch hole and causing sea water to go into compartment.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 6 February 2024
No resolution recorded
excess wastage was found on the bulkhead parrallel to the ladder needing gauging to determine severity of wastage or repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 February 2024
No resolution recorded
Upper side longitudinal adjacent to ladder attached to the bulkhead had excessive wastge, approximately four inch by 2 inch hole from end of side longitudinal to bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 6 February 2024
No resolution recorded
Bottom side longitudinal adjacent to the ladder at the bilge knuckle was missing approximately three feet from an incomplete previous repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 February 2024
No resolution recorded
Two longitudinals on the bottom of the compartment had excess wastage running throughout its entirity needing replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 February 2024
No resolution recorded
Two stiffners had excess wastage at the bottom where it was welded to the bottom transverse beam in excess of 25%.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 February 2024
No resolution recorded
Side longitudinals adjacent to the ladder had indentation that was a continuation of the indentation from PORT #1 wing void. The indentation was approximately five feet by three feet.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 February 2024
No resolution recorded
Two upper side longitudinals had indentation that spanned across approximately 20 feet by three feet and in excess of one inch into the compartment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 February 2024
No resolution recorded
Identified 29 welds from the overhead longitudinals were popped off needing replacement.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 21 November 2016
Resolved
Hole in flame screen over aft port tank.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 21 November 2016
Resolution: Satisfactory flame screen replaced.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 21 November 2016
Resolved
Containment plug missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 21 November 2016
Resolution: New plug fitted into containment prior to end of inspection.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 10 December 2008
Resolved
Per reg 33 CFR 155.1045(i), the TVRP must amend the geographic-specific appendix for the Mobile Bay Drilling Area to include notification to the state of Louisiana.
Due 10 January 2009
Resolved 22 July 2009
Resolution: Plan holder amended the TVRP to include the proper notification. Deficiency closed. TVRP expires 12/02/2013
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 31 August 2007
Resolved
No closure device for containment.
Condition: Improper/Lack of Maintenance
Due 14 September 2007
Resolved 4 March 2009
Stability › Watertight Integrity
Issued 18 July 2002
Resolved
Port side bow rake void cover gasket was torn. LEGACY COMPONENT DESC: man hole cover gasket
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2002
Resolution: Gasket was relaced.
Deck/Cargo › Holds/Tanks
Issued 18 July 2002
Resolved
Port #2 void space ladder rung was wasted and unsafe. LEGACY COMPONENT DESC: Ladder Rung
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2002
Resolution: Replaced ladder rung.
Deck/Cargo › Holds/Tanks › Hatch
Issued 18 July 2002
Resolved
#1 Port and Stbd forward cargo hatches and #2 Port and Stbd Aft cargo hatches wasted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2002
Resolution: Replaced all four wasted cargo tank hatches.
Deck/Cargo › Holds/Tanks
Issued 18 July 2002
Resolved
#1 Port cargo tank top was cracked.
LEGACY COMPONENT DESC: Cargo tank top insert
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2002
Resolution: Cut out and inserted to good metal. Insert size 8 FT by 6 FT. Dye Penetrant test SAT.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 18 July 2002
Resolved
#1 Port and Stbd cargo tank flame screens missing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2002
Resolution: New flame screens installed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 18 July 2002
Resolved
Emergency shutdown was not routed properly to allow for shutdown. Pulleys in system were wasted and nonfunctioning. Cable was not routed through all eyes in a few places..
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2002
Resolution: Cable was rerouted and pulleys replaced. System tested sat.
Documentation
Issued 12 July 1996
Resolved
Provide onboard notification checklist as required by 33CFR155.1040. NotifyUSCG when completed.
Condition: Unknown
Due 12 August 1996
Resolved 17 July 1996
Deck/Cargo
Issued 11 August 1995
Resolved
MAKE EMERGENCY ENGINE SHUT-DOWNS FOR STBD. CARGO PUMP ENGINE OPERATIONAL.
Condition: Unknown
Due 11 August 1995
Resolved 11 August 1995