Records from 2016 to 2025. Most recent: inspection, 31 March 2025.
Inspection history · 13
31 March 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8102709
1 December 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7607609
3 March 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7404776
1 June 2021
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7212353
13 November 2020
Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7094510
19 May 2020
DAPI Audit · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6965436
26 August 2019
Internal Structural Exam · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6796042
2 November 2018
Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6572573
26 April 2018
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6399096
21 September 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294380
22 August 2017
Internal Structural Exam · Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6451290
15 November 2016
Examination of Repairs · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6070455
23 August 2016
Internal Structural Exam · Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5982187
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 December 2022
No resolution recorded
Vessel's drydock and ISE was due at the end of NOV. Due to mechanical issues, vessel is unable to move. Vessel must complete drydock and ISE inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 March 2022
Resolved
Anchor/mast light is not working. Must conduct repairs prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2022
Resolution: Video received today showing the newly installed anchor/mast light working.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 March 2022
Resolved
FCC Safety Certificate expired. Must have VHF radio re certified and new FCC Safety Certificate issued.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2022
Resolved 16 March 2022
Resolution: Received photographic image of recently issued FCC Safety Radio Certificate, with expiry date of March 9th, 2027.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 March 2022
Resolved
Life float in black on the top. Must clean or repaint life float.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2022
Resolved 11 April 2022
Resolution: Repainted life float, labeled correctly
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 June 2021
Resolved
Guard on front of engine was taken off and never put back on after maintenance was completed. Must re install engine guard over pulleys/belts to protect injury while working on or near engine.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2021
Resolved 15 June 2021
Resolution: Received picture of engine guard installed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 June 2021
Resolved
Vessel does not have CG approved NAV chart onboard and the GPS with electronic chart will not turn on. Must have CG approved paper NAV chart on board or have access to electronic charts that meet requirements in NVIC 01-16.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2021
Resolved 16 June 2021
Resolution: Updated Garmin GPS with latest software.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 June 2021
Resolved
First aid kit was found to have expired items. Must replace expired items to meet requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2021
Resolved 2 June 2021
Resolution: Expired item in first aid kit was replaced. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 August 2019
Resolved
Life ring drop lines are wasted. Need to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2019
Resolution: New life ring was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 August 2019
Resolved
Life float needs repainted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2019
Resolution: Cracks in life float were repaired and float was repainted.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 August 2019
Resolved
Life float lines need to be secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2019
Resolution: All lines were neatly wrapped and stowed.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 2 November 2018
Resolved
Deck on the FWD port side of the cabin has a sewage pump out fitting that was not properly sealed, and has allowed water to ingress into the plywood deck and rot. Renew the decking and the beams associated with it, then re-glass decks.
Action required: 10 - Deficiency Rectified
Resolved 4 December 2018
Resolution: Rotten wood was cut out along a good beam, rotten structure below deck was renewed, and new marine grade plywood was installed. New deck was covered with 3 layers of biaxial cloth and epoxy.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 April 2018
Resolved
Audible alarm for fixed fire extinguishing system did not operate.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2018
Resolved 27 April 2018
Resolution: System fully functional
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 22 August 2017
Resolved
Bilge pump in tank space is inoperable. Reoair/renew.
Action required: 10 - Deficiency Rectified
Resolved 22 August 2017
Resolution: New bilge pump was installed prior to completion of the inspection.
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 August 2017
Resolved
Bilge high level alarm in aft compartment is inoperable. Repair/renew.
Action required: 10 - Deficiency Rectified
Resolved 22 August 2017
Resolution: New High level alarm was installed prior to the completion of the vessel inspection.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 August 2017
Resolved
Port nav light is extinguished. Repair/renew.
Action required: 10 - Deficiency Rectified
Resolved 22 August 2017
Resolution: Nav light bulb was replaced pior to the completion of the vessel inspection.
Navigation › Piloting/Steering › Magnetic Compass
Issued 22 August 2017
Resolved
Magnetic compass has a leak and is inoperable. Repair/renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2017
Resolved 1 September 2017
Resolution: New compass was provided.
Lifesaving › Lifefloat › Float-free Link
Issued 22 August 2017
Resolved
Float free link is not attached to the vessel. Attach per manufacturer instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2017
Resolved 1 September 2017
Resolution: Links were installed to the vessel cabin top under the painter line canister.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 22 August 2017
Resolved
Vessel does not have a logbook to prove monthly EPIRB testing and survival craft maintenance. Provide log.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2017
Resolved 1 September 2017
Resolution: New log was started and placed onboard.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 August 2016
Resolved
4 adult PFd were not servicable and must be replaced. Vessel is restricted to 13 passengers until new PFDs are provided.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 15 September 2016
Resolution: New Life jackets were purchased marked and placed in service.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 August 2016
Resolved
Annual Inspection of extinguishers was expired.
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 15 September 2016
Resolution: All extinguishers were inspected and are sat.
Lifesaving › Lifebuoys › Serviceable
Issued 23 August 2016
Resolved
grab lines on the ring buoy are wasted. Buoy will need to be replaced or repaired.
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 15 September 2016
Resolution: ring buoy was replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 August 2016
Resolved
Bow light is inop. Vessel in not allowed to operate at night until new bow light is provided and tested.
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 15 September 2016
Resolution: Bow light was repaired and tested all sat.
Lifesaving › Lifefloat › Serviceable
Issued 23 August 2016
Resolved
Life float is in need of new grablines, paint, and retro.
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 15 September 2016
Resolution: Life float was repainted and marked, new retro was installed.
Navigation › Piloting/Steering › US Coast Pilot
Issued 23 August 2016
Resolved
Vessel does not have any of the required charts and pubs onboard. Provide new charts and publications.
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 15 September 2016
Resolution: New charts and new publications placed onboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 August 2016
Resolved
Vessel's first aide kit is incomplete and expired. provide new kit.
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 15 September 2016
Resolution: New approved first aid kit was placed into service.
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 August 2016
Resolved
Vessel's remote fuel shut-off valves are not marked.
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 15 September 2016
Resolution: Shut-offs are marked.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 23 August 2016
Resolved
Vessel does not have a log for drills or survival craft maint.
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 15 September 2016
Resolution: New logs were created and are sat.
Engineering › Steering Gear System › Actuator
Issued 23 August 2016
Resolved
Vessel has emergency tiller but changes in the rudder have made it unusable. Prove proper operation.
Action required: 705 - Other - as specified
Due 13 September 2016
Resolved 24 April 2019
Resolution: Vessel repaired tiller, but it was never reflected in MISLE
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 23 August 2016
Resolved
Vessel does not have a valid FCC Safety cert.
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 15 September 2016
Resolution: New FCC radio safety cert was placed onboard.