MAURY USCG vessel records Sign in
← All vessels

J&J NEWHALL

J&J NEWHALL is a 2000 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2000, most recently in April 2026, along with 19 deficiencies.

Records from 2000 to 2026. Most recent: inspection, 1 April 2026.

Built
2000
Last inspected
1 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-19468

Inspections, by type

…with no type recorded1
Years with a record 22 calendar years (2000–2026)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 32

1 April 2026 Vessel Attendance · Appeal · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8308823
7 July 2025 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8111975
8 July 2024 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7932371
2 April 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7878530
6 July 2023 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7700471
13 July 2022 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7469616
5 April 2022 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7405297
13 July 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7254525
8 July 2020 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6987742
1 April 2020 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6933660
10 July 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6744689
11 July 2018 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6475725
29 May 2018 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6427303
17 April 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6393913
12 July 2017 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6206697
14 July 2016 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5940882
20 April 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5859263
21 July 2015 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5191058
13 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4206978
16 August 2011 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4118655
6 August 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3291479
6 May 2008 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3200227
16 October 2007 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3082186
22 August 2006 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2755728
19 April 2005 Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2455698
20 September 2004 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2200041
29 April 2003 Internal Structural Exam · Deficiency Check · Annual Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1785045
17 October 2002 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1702156
7 October 2002 Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1685674
5 September 2001 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1435275
12 June 2000 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1426498
25 April 2000 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1055955

Deficiency record · 19

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 July 2025 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Portable fire extinguishers were not being inspected monthly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 16 July 2025
Resolution: Operator added monthly checks of fire extinguishers to vessel's log book.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 July 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Life ring buoy's grab line showed significant UV damage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 16 July 2025
Resolution: Operator replaced life ring buoy.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 July 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts and nautical publications. Chart on board is not kept up-to-date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 16 July 2025
Resolution: Operator downloaded and printed the most current charts for their operating area.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 July 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel had exposed wires in the operator's console.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 26 July 2021
Resolution: Vessel terminated exposed wires.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 July 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The vessel's first aid kit had expired medication and equipment inside.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 26 July 2021
Resolution: Vessel replaced espired equipment in the first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 July 2021 Resolved
A submersible electric bilge pump may be used as a power bilge pump only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that a positive shutoff valve is installed at the hull penetration. The positive action valve was not installed at the penetration. Rectify prior to next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 April 2022
Resolution: Operator installed a positive action valve for the bilge system.
Documentation › Certificates/Documents › Stability Letter
Issued 13 December 2011 Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. TO VERIFY COMPLIANCE, A STABILITY TEST MUST BE COMPLETED. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THERFORE LIMITED TO: 16 PERSONS(PASSENGERS AND CREW)
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 27 April 2012
Resolution: Issued new stability letter based upon weight ratio calcs on sister MARINE SHUTTLE.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 6 May 2008 Resolved
Replace cutlass bearing
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 6 August 2008
Resolution: Bearing replaced
Accommodation/Occupational Safety › Occupational Safety
Issued 29 April 2003 Resolved
Replace rail in way of boarding platform. LEGACY COMPONENT DESC: Deck Rail
Due 30 May 2003
Resolved 29 April 2003
Engineering › Shafting/Propeller Arrangements
Issued 29 April 2003 Resolved
Replace cutlass bearing. LEGACY COMPONENT DESC: Bearing
Due 30 May 2003
Resolved 30 April 2003
Resolution: Cutlass bearing replaced.
Engineering › Shafting/Propeller Arrangements
Issued 29 April 2003 Resolved
Install shaft key LEGACY COMPONENT DESC: Propeller Shaft
Due 30 May 2003
Resolved 30 April 2003
Resolution: Shaft key installed.
Accommodation/Occupational Safety › Medical/First Aid
Issued 7 October 2002 Resolved
Re-supply first aid kit with required items. LEGACY COMPONENT DESC: Medicine Chest
Due 18 October 2002
Resolved 16 June 2003
Resolution: First aid kit replenished.
Fire Fighting › Ventilation Systems
Issued 7 October 2002 Resolved
Provide means to secure ventilation to engine room.
Due 18 October 2002
Resolved 16 June 2003
Resolution: Means to secure ventilation provided.
Engineering › Bilge Water Management System
Issued 7 October 2002 Resolved
Install positive stop closure valve to the overboard discharge hose of bilge pump. LEGACY COMPONENT DESC: Valve
Due 18 October 2002
Resolved 16 June 2003
Resolution: Valve installed.
Operations/Management › Drills/Instruction
Issued 7 October 2002 Resolved
Document training drills (fire/man overboard) in logbook. LEGACY COMPONENT DESC: Fire
Due 18 October 2002
Resolved 16 June 2003
Resolution: Training logged.
Operations/Management › Drills/Instruction
Issued 7 October 2002 Resolved
Re-write emergency instructions to list required steps or vessel crew to take in case of fire on board vessel. LEGACY COMPONENT DESC: Fire
Due 18 October 2002
Resolved 16 June 2003
Resolution: Emergency instructions rewritten.
Communications › Audible Communications
Issued 7 October 2002 Resolved
Provide proper size bell for vessel. LEGACY COMPONENT DESC: Bell
Due 18 October 2002
Resolved 16 June 2003
Resolution: Bell provided.
Lifesaving › Lifejacket/PFD (Type I)
Issued 7 October 2002 Resolved
Mark lifejackets with vessels name. LEGACY COMPONENT DESC: Marking
Due 18 October 2002
Resolved 16 June 2003
Resolution: PFDs marked.
Lifesaving › Lifebuoys
Issued 7 October 2002 Resolved
Mark lifebuoy with vessel's name. LEGACY COMPONENT DESC: Markings (ship name/port)
Due 18 October 2002
Resolved 16 June 2003
Resolution: Ring life buoy marked.

Ownership record