MAURY USCG vessel records
← All vessels

BELLA LUNA

BELLA LUNA is a 1979 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2017, most recently in August 2025, along with 69 deficiencies, 1 operational control and 1 casualty investigation in 2020.

Records from 2017 to 2025. Most recent: inspection, 6 August 2025.

Built
1979
Last inspected
6 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDI4300
194994
Flag
UNITED STATES
Maury page id
psix-194994

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 9 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)52.0 ft × 12.0 ft × 5.5 ft
Registered tonnagegross 22 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOASTAL YACHTS · RICHLAND, MO, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Gross Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 22

6 August 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8204131
1 October 2024 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8012143
8 August 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7976964
12 November 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7824311
24 August 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7775589
3 October 2022 Construction Oversight · Internal Structural Exam · Simplified Stability Test · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7572718
16 August 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7528205
28 September 2021 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7322468
14 July 2021 Administrative Inspection · Drydock Extension
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7256403
12 May 2021 Administrative Inspection · Deficiency Check · Damage Survey · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7194960
6 September 2020 Administrative Inspection · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7051635
5 September 2020 Type not recorded
No type recorded · Station San Diego · USCG Southwest District (CGD-SW) · Activity 7051128
5 September 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7078585
18 August 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7035691
21 November 2019 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6859836
19 August 2019 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6788071
9 July 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6742614
22 October 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6564596
1 November 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6299177
28 September 2017 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6277490
21 June 2017 Examination of Repairs · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6182283
10 February 2017 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6090644

Deficiency record · 69

07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 August 2025 Resolved
Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with 46 CFR 164.009 in Subchapter Q of this chapter, or other standard specified by the Commandant. The engine room's forward and upper boundaries are missing sections of their non-combustible panels. Replace the missing sections of non-combustible panels with ones that meet 46 CFR 164.009. 46 CFR 177.410(c)(4)
Action required: 705 - Other - as specified
Resolved 22 August 2025
Resolution: Observed installation of non-combustible panels. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 August 2025 Resolved
Vessel shall install a modular smoke detecting unit in the forward accommodation space. The unit must meet UL 217. 46 CFR 177.410(c)(3)
Action required: 705 - Other - as specified
Resolved 22 August 2025
Resolution: Observed smoke detector. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2025 Resolved
Vessel is short by 05 adult lifejackets and 01 child lifejacket. Vessel may not carry more than 46 adults and/or 05 children, with the total persons not to exceed 51, until this deficiency is rectified. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 22 August 2025
Resolution: Observed 05 adult life jackets and 01 child lifejacket. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 August 2025 Resolved
Vessel's design prevents vessel from serving as a rescue craft due to the high freeboard. Recreational swim ladder previously used as a rescue platform was found broken. Replace rescue platform with one that can help a crewmember recover a helpless person from the water. To be rectified by 05 September 2025. 46 CFR 180.210(b)
Action required: 705 - Other - as specified
Due 5 September 2025
Resolved 8 September 2025
Resolution: Vessel provided image of new ladder with specifications. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 August 2024 Resolved
Life ring grab lines were found to be deteriorated, repair or replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 3 September 2024
Resolution: Life ring was was replaced and properly labeled.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 August 2024 Resolved
Provide fire-stop on two forward bulkhead penetrations for machinery space. Make the compartment vapor-tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 3 September 2024
Resolution: Bulkheads were properly sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 August 2024 Resolved
Provide fuel fill hose with bonding wire between metal fittings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 3 September 2024
Resolution: Bonding wire was installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 24 August 2023 Resolved
FCC Safety Radio Certificate found to be expired. Provide recent certificate.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2023
Resolution: Provided proof of radio certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 August 2023 Resolved
Exposed wires found IWO "Smugglers room" three under near the bilge pump, two under the access step, and three under the bar. Terminate wires in a junction box with pressure type connector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2023
Resolution: Terminated wires in junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 August 2023 Resolved
Center batteries found to be installed without a battery box. Provide battery box and top cover for all battery installations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2023
Resolution: Provided box for battery installation
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 3 October 2022 Resolved
Vessel performed engine re-power requiring Simplified Stability Test. Test Scheduled 15NOV2022. Vessel limited to 11 passengers on top deck until test complete.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 January 2023
Resolution: Conducted Simplified Stability Test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 August 2022 Resolved
Port Propulsion engine air filter unit cover not properly secured in place; Provide adequate means to re- secure air filter unit cover.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2022
Resolution: Received photo of installation of proper hardware to secure air filter unit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 August 2022 Resolved
Port propulsion engine’s performance during dock and sea trials were noted as follows; Loud knocking sound coming from area of Air filter unit center forward section; abnormal and unusual. Propulsion engine service technician to diagnose engine performance and provide condition found report to include any corrective actions necessary. Master to provide attestation, signature with MMD license number to [email withheld] that the performance of the propulsion engine can be safely operated for the duration of its service life.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2022
Resolution: Received Master's and third party survey attestation to engine diagnostics and conditions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 August 2022 Resolved
Both propulsion engines exhaust pipe lagging deteriorated; repair / replace lagging.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 September 2022
Resolution: Recieved pictures of installed lagging to exhaust piping.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 August 2022 Resolved
Electric water heater access cover to thermostat and wiring missing. Install adequate electrical cover plate.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 September 2022
Resolution: REcieved pictures of installed cover to hot water heater.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 August 2022 Resolved
Radiotelephony certificate expired Oct 2020.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2022
Resolution: Received photo screenshot of FCC license due date 06/09/2026.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 May 2021 Resolved
Vessel’s FCC Safety Certificate was expired, provide vessel with valid certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 29 June 2021
Resolution: Vessel Owner emailed pictures of rectified def.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 12 May 2021 Resolved
Vessels’ installed DSC VHF radio was missing MMSI number and lat/long location inputs, provide radio with MMSI and position information.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 14 July 2021
Resolution: Verified onboard
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2021 Resolved
Vessel’s life ring grab lines were found deteriorated and serviceable, provide vessel with new life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 14 July 2021
Resolution: Verified
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 May 2021 Resolved
Vessel’s distress signals were being stored in a clear plastic food storage container, provide vessel with a portable watertight container which is bright color. Label container in ½” lettering “DISTRESS SIGNALS”
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 29 June 2021
Resolution: Vessel Owner emailed pictures of rectified def.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 12 May 2021 Resolved
Vessel's Generator exhaust pipe was found corroded and separated from generator. Provide & Install new metallic exhaust fitting to elbow with double hose clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 29 June 2021
Resolution: Vessel Owner emailed pictures of rectified def.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 May 2021 Resolved
Junction Box in engine room located on the STBD aft bulkhead was missing cover. Install cover on Junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 29 June 2021
Resolution: Vessel Owner emailed pictures of rectified def.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 May 2021 Resolved
Dead wire was found in engine room located on the Port Fwd bulkhead. Properly cap or remove dead end wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 29 June 2021
Resolution: Vessel Owner emailed pictures of rectified def.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 September 2020 Resolved
Following a grounding, Have divers perform a damage survey of entire hull area and all UW appendenages and inlets or haul out vessel onto secure blocks to ascertain extent of any damage PRIOR to departure from berthing and PRIOR to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2020
Resolution: No structural damage found. All Cleared
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 18 August 2020 Resolved
Must properly mount starboard blower in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 23 September 2020
Resolution: Vessel operator emailed picture of corrected def.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 18 August 2020 Resolved
Must properly mount fuel shut off cable for generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 23 September 2020
Resolution: Vessel operator emailed picture of corrected def.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 18 August 2020 Resolved
Must properly secure junction cover for main generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 23 September 2020
Resolution: Vessel operator emailed picture of corrected def.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 18 August 2020 Resolved
Provide trays or box lined, or constructed of, a corrosion resistant material to prevent damage from electrolytes and harmful gases.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 23 September 2020
Resolution: Vessel operator emailed picture of corrected def.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 18 August 2020 Resolved
Must properly install CG approved SAE J-1942 fuel hosing for both main engine's and generator's supply and return fuel lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 23 September 2020
Resolution: Vessel operator emailed picture of corrected def.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 August 2019 Resolved
Vesssel missing pre-engineered fixed FF alarm at normal operating station, upper helm. 46 CFR 181.420(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 30 September 2019
Resolution: Installed FF alarm at upper operating station.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 August 2019 Resolved
Inop stern light. Lens on port and stbd running lights needs to be replaced. Make changes to nav light configuration to not affect night vision when operating from the fly bridge IAW 33 CFR 83.22(b) Prior to nightime ops.
Action required: 705 - Other - as specified
Resolved 17 September 2019
Resolution: Operator provided photo of rectified def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 August 2019 Resolved
Make generator operational. Identified that starter is not functional. 46 CFR 183.200 Electrical systems must be maintained to operate under working conditions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 21 November 2019
Resolution: Operationally Inspected SAT.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 August 2019 Resolved
Required to have blowers secured. Blowers not currently being used and not secured. 46CFR181.420(a)3 Must have power ventilations shut down in protected spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 30 September 2019
Resolution: Power vent shuts down with fire boy simulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 August 2019 Resolved
Port engine has a water pump leak. Appx one drip per second with engine running. 46 CFR 182.100 Equipment must be maintained properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 17 September 2019
Resolution: Operator provided photo of rectified def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 August 2019 Resolved
Stbd shaft leaks water. Five drips per second. 46CFR182.100 Maintain machinery in operable condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 21 November 2019
Resolution: Operationally Inspected SAT.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 19 August 2019 Resolved
Vessel does not have working mag compass on upper helm/primary operating station. 46 CFR 184.402(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 17 September 2019
Resolution: New compass at helm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 August 2019 Resolved
Upper starboard lube oil pressure gauge not working properly. Make gauge operational. 46 CFR 182.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 21 November 2019
Resolution: Operationally Inspected SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 August 2019 Resolved
Starboard lower helm RPM gauge not operating properly. Make gauge operational. 46 CFR 182.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 21 November 2019
Resolution: Operationally Inspected SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 August 2019 Resolved
Lifejacket stowage labeling does not match actual number of jackets stowed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 19 August 2019
Resolution: Label updated to show accurate number of jackets.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 October 2018 Resolved
Vessels are require to conduct an Annual inspection within 3 months (before or after) the anniversary date. The vessel's anniversary date is 27 May and the annual inspection has not been completed for CY2018. Make vessel available for annual inspection in accordance with 46CFR176.500(b)(1).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 October 2018 Resolved
Pocure 02 additional distress signals/flares,; either red hand flare or orange smoke flare
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2018
Resolved 16 November 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 October 2018 Resolved
Submit drug and alcohol MIS report for the year of 2017. 46CFR15.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2018
Resolved 20 November 2018
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 October 2018 Resolved
Procure current/up to date charts and publications or excerpts per 46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2018
Resolved 16 November 2018
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 October 2018 Resolved
Provide fire extinguisher servicing report to include fire-boy system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2018
Resolved 16 November 2018
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 November 2017 Resolved
Did not provide current alcohol testing strips.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 13 November 2017
Resolution: Test strips provided.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 2 November 2017 Resolved
Did not provide drug testing for past random exams.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 13 November 2017
Resolution: Testing kits provided.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 2 November 2017 Resolved
Did not provide log book with drills.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 7 November 2017
Resolution: Log book provided.
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 November 2017 Resolved
No complete drills with all crew prior to taking passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2017
Resolved 7 November 2017
Resolution: Drills completed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 2 November 2017 Resolved
Did not provide lock for sewage overboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2017
Resolved 7 November 2017
Resolution: Sewage overboard in space that is inaccessible meeting intent of regulation.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 2 November 2017 Resolved
Repair cleat fracture port side.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: New cleat glassed in.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 2 November 2017 Resolved
Did not make bilges clean and ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2017
Resolved 13 November 2017
Resolution: Bilges made clean.
Engineering › Fuel Oil Service System › Hose
Issued 2 November 2017 Resolved
All vital systems lacking hose clamps.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 13 November 2017
Resolution: Hose clamps provided.
Electrical › Electric Generation Source (service) › Number of Sources
Issued 2 November 2017 Resolved
Make all electrical have supports every 24 inches.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 13 November 2017
Resolution: Supports provided.
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 November 2017 Resolved
Have battery connections tight and battery secure port side.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: Battery and connections secure.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 2 November 2017 Resolved
Repair port main engine exhaust leak.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: Exhaust replaced with new piping.
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 2 November 2017 Resolved
Repair port aft motor mount, cracked, and fractured.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2017
Resolved 13 November 2017
Resolution: Motor mount replaced.
Engineering › Fuel Oil Service System › Hose
Issued 2 November 2017 Resolved
Cap open hoses.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 13 November 2017
Resolution: Hose capped.
Fire Fighting › Fire Bucket › Lanyard
Issued 2 November 2017 Resolved
Provide lines on fire buckets.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 2 November 2017
Resolution: Lanyards attached to the firebucket.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 2 November 2017 Resolved
Repair raw water inlet. Loose and/or fractured.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 13 November 2017
Resolution: Raw water pipe secured.
Lifesaving › Rocket Parachute Flares › General
Issued 2 November 2017 Resolved
Provide 3 hand flares.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 7 November 2017
Resolution: Flares provided.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 2 November 2017 Resolved
Provide 5 additiaonal TYPE I PFDs.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 7 November 2017
Resolution: 5 new lifejackets provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 November 2017 Resolved
Provide an audible and visual high water alarm in the F/O tank compartment.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: High water alarm installed in F/O compartment.
Engineering › Bilge Water Management System › Pump
Issued 2 November 2017 Resolved
Provide a bilge pump in the F/O tank compartment.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: Bilge pump installed in F/O compartment.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 November 2017 Resolved
Provide an audible and visual high water alarm at the topside operating station.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: Alarm installed at upper helm station.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 November 2017 Resolved
Provide working lifebuoy light.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 13 November 2017
Resolution: New battery installed. Light works.
Engineering › Fuel Oil Service System › Gauge
Issued 1 November 2017 Resolved
Provide working starboard oil pressure gauge on upper helm.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 13 November 2017
Resolution: Gauge repaired.
Fire Fighting › Ventilation Systems › Ducts
Issued 1 November 2017 Resolved
Provide means of closing engine room ventilation.
Action required: 705 - Other - as specified
Due 2 December 2017
Resolved 22 December 2017
Resolution: Fabric closures with snap buttons installed for engine room ventilation closure.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 September 2017 Resolved
This Vessel is required to have a original valid certificate of documentation onboard the vessel. Provide a valid certificate of documentation to the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2017
Resolved 29 September 2017
Resolution: Valid
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 June 2017 Resolved
Repair unserviceable battery box
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 31 July 2017

Casualty record · 1

5 September 2020Routine · role: Involved in a Marine Casualty · activity 7078585
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.