Records from 2001 to 2003. Most recent: inspection, 12 February 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 February 2003
No resolution recorded
Vessel limited to day time operation only or until an approved floatinf water light is installed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 February 2003 — due date passed with no resolution recorded
Fire Fighting › Fixed Fire Detection System
Issued 3 February 2003
Resolved
Install an approved fire detecting system. LEGACY COMPONENT DESC: Heat Detectors
Condition: Unknown
Due 13 February 2003
Resolved 12 February 2003
Accommodation/Occupational Safety
Issued 3 June 2002
Resolved
Clean all debris from the bilge of the vessel.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2002
Resolved 3 February 2003
Electrical › Electrical Distribution System (service)
Issued 3 June 2002
Resolved
Remove all dead-end wiring. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2002
Resolved 3 February 2003
Engineering › Bilge Water Management System
Issued 3 June 2002
Resolved
Repair hose to aft bilge pump discharge. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2002
Resolved 3 February 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 3 June 2002
Resolved
Replace the existing dry chemical fire extinguisher w/CO2 for the engine compartment as required.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2002
Resolved 3 February 2003
Fire Fighting › Fixed Fire Detection System
Issued 3 June 2002
Resolved
Install an approved heat detedtion system in the engine compartment as required.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2002
Resolved 12 February 2003
Resolution: Owner installed a heat sensor that sounds a buzzer at the operating station and illuminates a red light. The buzzer is tied into the bilge alarm, but the light is seperate.
Lifesaving
Issued 10 December 2001
Resolved
Provide and post emergency instructions, i.e., fire/MOB/heavy wx, as required by 46CFR185.
Condition: Unknown
Due 20 December 2001
Resolved 21 December 2001
Lifesaving
Issued 10 December 2001
Resolved
Provide instructions on how to put on a lifejacket as required by 46CFR185.
Condition: Unknown
Due 20 December 2001
Resolved 21 December 2001
Lifesaving
Issued 10 December 2001
Resolved
Mark lifejacket stowage location and the total number of adult and child's lifejackets.
Condition: Unknown
Due 20 December 2001
Resolved 21 December 2001
Lifesaving › Hand Flares
Issued 10 December 2001
Resolved
Provide three required orange, smoke flares for rivers route.
Condition: Unknown
Due 20 December 2001
Resolved 21 December 2001
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 December 2001
Resolved
Provide 60 feet of buoyant lifeline for ring buoy; current line sinks.
Condition: Unknown
Due 20 December 2001
Resolved 7 February 2002
Fire Fighting
Issued 10 December 2001
Resolved
Provide required A-II portable fire extinguisher missing fm vsl.
Condition: Unknown
Due 20 December 2001
Resolved 5 February 2002
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 10 December 2001
Resolved
Provide one flashlight for the required two for emergency lighting and replace the dead batteries.
Condition: Unknown
Due 20 December 2001
Resolved 7 February 2002
Engineering
Issued 10 December 2001
Resolved
Move fuel vents from passenger space to the exterior of the hull as high above the waterline as practicable and remote fm any hull openings.
Condition: Unknown
Due 10 January 2002
Resolved 28 December 2001
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 10 December 2001
Resolved
Mark all lifejackets with the vessel's name.
Condition: Unknown
Due 20 December 2001
Resolved 21 December 2001
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2001
Resolved
Prior to carriage of passengers, provide proof of an approved drug audit program.
Condition: Unknown
Due 10 December 2001
Resolved 7 February 2002
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 December 2001
Resolved
Prior to the carriage of passengers, provide retro-reflective tape for chidlren's lifejackets.
Condition: Unknown
Due 10 December 2001
Resolved 21 December 2001
Lifesaving › Lifebuoys
Issued 10 December 2001
Resolved
Provide retro-reflective tape for the ring life buoy.
Condition: Unknown
Due 20 December 2001
Resolved 7 February 2002