Records from 2001 to 2012. Most recent: inspection, 1 May 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 28 April 2008
Resolved
Renew shaft cutlass bearing.
Due 28 May 2008
Resolved 28 April 2008
Resolution: Renewed shaft cutlass bearing.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 16 May 2007
Resolved
Properly install approved fixed firefighting system IAW 46CFR181.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2007
Resolved 1 August 2007
Engineering › Bilge Water Management System › Pump
Issued 16 May 2007
Resolved
Repair and demonstrate proper operation of manual bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2007
Resolved 25 June 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 16 May 2007
Resolved
Place life jacket donning placard in a more accessible location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 May 2007
Resolved 25 June 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 May 2007
Resolved
Renew bilge alarm enunciator at operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2007
Resolved 25 June 2007
Engineering › Reduction Gearing/Clutches › Shaft
Issued 16 May 2007
Resolved
Renew output shaft seal on marine gear, and demonstrate proper operation.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2007
Resolved 1 August 2007
Resolution: Rebuilt marine gear.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 February 2006
Resolved
must seperate child/adult PFDs
Due 31 March 2006
Resolved 4 April 2006
Engineering › Fuel Oil Service System › Vent Pipe
Issued 23 February 2006
Resolved
must replace fuel tank vent on outboard stanchion with correct tubing and mesh screen.
Due 31 March 2006
Resolved 4 April 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 23 February 2006
Resolved
must renew exhaust hose with flexible hose
Due 31 March 2006
Resolved 4 April 2006
Engineering › Bilge Water Management System › Not Installed
Issued 23 February 2006
Resolved
must provide bilge alarm light
Due 31 March 2006
Resolved 4 April 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 February 2006
Resolved
Line was old and worn
Condition: Improper/Lack of Maintenance
Due 28 March 2006
Resolved 23 March 2006
Resolution: renewed
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 23 February 2006
Resolved
no ventilation on battery box
Condition: Design Flaw
Due 28 March 2006
Resolved 23 March 2006
Resolution: renewed battery box
Documentation › Markings/Placards › Lifejacket Placard
Issued 23 February 2006
Resolved
old and unreadable
Condition: Improper/Lack of Maintenance
Due 28 March 2006
Resolved 23 March 2006
Resolution: renewed placard
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 February 2006
Resolved
make life jackets accessable
Due 28 March 2006
Resolved 23 March 2006
Resolution: added plastic release snaps to the overhead hanging lifejackets
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 23 February 2006
Resolved
missing emer steering hardware
Condition: Unknown
Due 28 March 2006
Resolved 23 March 2006
Resolution: fabricated emergency steering tiller
Navigation › Piloting/Steering › Magnetic Compass
Issued 23 February 2006
Resolved
compass needs to be mounted so visible from primary operating station and illuminated if operating at night
Condition: Improper Installation
Due 28 March 2006
Resolved 23 March 2006
Resolution: installed
Engineering › Fuel Oil Service System › Valve, Control
Issued 23 February 2006
Resolved
renew emergency fuel shut-off
Due 28 March 2006
Resolved 23 March 2006
Resolution: renewed
Engineering › Bilge Water Management System › Pump
Issued 23 February 2006
Resolved
renew submersible pump with UL rated pump and positive action valve
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2006
Resolution: renewed with UL rated pump
Construction/Loadline › Structures › Superstructure
Issued 23 February 2006
Resolved
Wooden superstructure and deck shade had some damaged, old wooden supports that need to be replaced
Condition: Improper/Lack of Maintenance
Due 28 March 2006
Resolved 23 March 2006
Resolution: renewed wooden supports
Engineering › Fuel Oil Service System › Piping
Issued 23 February 2006
Resolved
renew fuel hose return with approved type
Condition: Improper/Lack of Maintenance
Due 28 March 2006
Resolved 23 March 2006
Resolution: renewed with stainless hose
Fire Fighting › Fire Bucket › Availability
Issued 23 February 2006
Resolved
provide 3 fire buckets
Due 28 March 2006
Resolved 23 March 2006
Resolution: provided
Fire Fighting › Fixed Fire Detection System
Issued 3 February 2003
Resolved
Install an approved fire detection system. LEGACY COMPONENT DESC: Heat Detectors
Condition: Improper Installation
Due 13 February 2003
Resolved 12 February 2003
Resolution: owner installed a heat sensor which activates a light and a buzzer at the operating station. The light is seperate and the audible is tied into the bilge alarm.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 February 2003
Resolved
Vessel limited to daytime operation only or until an approved waterlight is installed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 April 2006
Resolved 19 April 2006
Lifesaving › Emergency Outfit
Issued 3 February 2003
Resolved
Renew/repair two hand hel flashlights. LEGACY COMPONENT DESC: Flashlight
Condition: Improper/Lack of Maintenance
Due 13 February 2003
Resolved 12 February 2003
Accommodation/Occupational Safety
Issued 3 February 2003
Resolved
Install/ provide approved first aid kit. LEGACY COMPONENT DESC: First Aid Kit
Condition: Unknown
Due 13 February 2003
Resolved 12 February 2003
Documentation › Logs/Records › Drug Test Records
Issued 10 December 2001
Resolved
Prior to the carriage of passengers, provide proof of a valid drug audit program.
Condition: Unknown
Due 20 December 2001
Resolved 12 December 2001
Engineering › Fuel Oil Service System › Valve
Issued 10 December 2001
Resolved
Repair/replace/realign fuel shutoff valve reach rod to provide positive fuel shutoff.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 21 December 2001
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 December 2001
Resolved
Provide 60 feet of buoyant lifeline for life ring buoy.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 7 February 2002
Lifesaving
Issued 10 December 2001
Resolved
Provide and post emergency instructions, i.e., fire/man overboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 21 December 2001
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 December 2001
Resolved
Provide and post instructions on how to put on a lifejacket.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 21 December 2001
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 10 December 2001
Resolved
Mark lifejacket stowage location and the number of adult and children's lifejackets.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 21 December 2001
Lifesaving › Hand Flares
Issued 10 December 2001
Resolved
Provide 3 orange, smoke flares as required for Rivers route.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 21 December 2001
Fire Fighting
Issued 10 December 2001
Resolved
Provide required A-II fire extinguisher.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 21 December 2001
Electrical › Lighting (emergency)
Issued 10 December 2001
Resolved
Provide one additional flashlight to have the required two o/b vsl for emergency lighting.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 21 December 2001
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 10 December 2001
Resolved
Mark all lifejackets with the vessel's name.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 21 December 2001
Engineering
Issued 10 December 2001
Resolved
Move fuel tank vents fm emitting directly onto passengers to the exterior of the hull as high above the waterline as practicable and remote fm any hull openings.
Condition: Unknown
Due 20 January 2002
Resolved 7 February 2002
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 December 2001
Resolved
Prior to the carriage of passengers, provide retro-reflective tape on children's lifejackets.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 21 December 2001